What's new in transapical aortic valve implantation: clinical experience with second generation devices

被引:0
|
作者
Conradi, L. [1 ]
Seiffert, M. [1 ]
Blankenberg, S. [1 ]
Reichenspurner, H. [1 ]
Diemert, P. [1 ]
Treede, H. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Univ Heart Ctr Hamburg, D-20246 Hamburg, Germany
来源
MINERVA CARDIOANGIOLOGICA | 2013年 / 61卷 / 03期
关键词
Aortic valve stenosis; Aortic valve; Heart valve prosthesis implantation; TRANSCATHETER; REPLACEMENT; STENOSIS; 1ST;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Within 10 years after transcatheter aortic valve implantation (TAVI) was first accomplished for treatment of calcified aortic stenosis, this new technology has rapidly evolved to become clinical routine. Today it may be considered standard treatment for inoperable patients with superior outcomes compared to best medical therapy. Furthermore, it represents an alternative therapeutic option compared to surgical aortic valve replacement in high-risk patients. According to current international guidelines and expert consensus statements, TAVI should be performed as a joint effort by an interdisciplinary heart team to ensure input from multiple skill sets for optimal patient outcome. Major safety concerns include neurologic complications, acute kidney injury, access site complications, procedure-related conduction disturbances, paravalvular leakage valve durability. At present, only one device for transapical TAVI is in widespread clinical use: the Edwards Sapien transcatheter valve (Edwards Lifesciences, Irvine, CA, USA). Recently, however, a number of second generation devices for transapical TAVI have been developed in order to address some of the limitations of first generation valves. In this paper, current data on second generation devices for transapical TAVI will be reviewed and ongoing trials discussed.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 50 条
  • [31] Clinical and Hemodynamic Outcomes of Transapical Aortic Valve Implantation: Two Years Experience in 155 Patients
    D'Onofrio, Augusto
    Fusari, Melissa
    Abbiate, Nicola
    Zanchettin, Chiara
    Bianco, Roberto
    Fabbri, Alessandro
    Salvador, Loris
    Polesel, Elvio
    Biglioli, Paolo
    Gerosa, Gino
    CIRCULATION, 2010, 122 (21)
  • [32] Aortic valve prosthesis tracking for transapical aortic valve implantation
    M. E. Karar
    D. R. Merk
    C. Chalopin
    T. Walther
    V. Falk
    O. Burgert
    International Journal of Computer Assisted Radiology and Surgery, 2011, 6 : 583 - 590
  • [33] Transapical transcatheter aortic valve replacement for aortic regurgitation with a second-generation heart valve
    Liu, Huan
    Yang, Ye
    Wang, Wenshuo
    Zhu, Da
    Wei, Lai
    Guo, Kefang
    Zhao, Weipeng
    Yang, Xue
    Zhu, Liming
    Guo, Yingqiang
    Wang, Wei
    Wang, Chunsheng
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (01): : 106 - 116
  • [34] Transapical Aortic Valve Implantation: 6 and 12 Months Results From a Multicenter Study Using the JenaValve Second Generation Transcatheter Aortic Valve Implantation System
    Treede, Hendrik
    Baldus, Stephan
    Rastan, Ardawan
    Figulla, Hans
    Ferrari, Markus
    Ensminger, Stephan
    Arnold, Martin
    Walther, Thomas
    Kempfert, Joerg
    Bleiziffer, Sabine
    Mohr, Friedrich
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B32 - B32
  • [35] Concomitant Transapical Transcatheter Aortic Valve Implantation and Transapical Mitral Valve Repair With NeoChord Implantation
    Stelzmueller, Marie-Elisabeth
    Zilberszac, Robert
    Heinrich, Nikolaus
    Mora, Bruno
    Laufer, Guenther
    Wisser, Wilfried
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (06) : 564 - 568
  • [36] The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation
    Silaschi, Miriam
    Conradi, Lenard
    Wendler, Olaf
    Schlingloff, Friederike
    Kappert, Utz
    Rastan, Ardawan J.
    Baumbach, Hardy
    Holzhey, David
    Eichinger, Walter
    Bader, Ralf
    Treede, Hendrik
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (07) : 1345 - 1351
  • [37] Transaortic Transcatheter Aortic Valve Implantation as a second choice over the Transapical access
    Ropponen, J.
    Vainikka, T.
    Sinisalo, J.
    Rapola, J.
    Laine, M.
    Ihlberg, L.
    SCANDINAVIAN JOURNAL OF SURGERY, 2016, 105 (01) : 35 - 41
  • [38] Rescue valve-in-valve implantations in second generation transapical transcatheter aortic valve prostheses
    Van Linden, Arnaud
    Blumenstein, Johannes
    Walther, Thomas
    Moellmann, Helge
    Kim, Won Keun
    Hamm, Christian
    Kempfert, Joerg
    CLINICAL RESEARCH IN CARDIOLOGY, 2013, 102 (03) : 241 - 243
  • [39] Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation
    Gutierrez, Marcos
    Rodes-Cabau, Josep
    Bagur, Rodrigo
    Doyle, Daniel
    DeLarochelliere, Robert
    Bergeron, Sebastien
    Lemieux, Jerome
    Villeneuve, Jacques
    Cote, Melanie
    Bertrand, Olivier F.
    Poirier, Paul
    Clavel, Marie-Annick
    Pibarot, Philippe
    Dumont, Eric
    AMERICAN HEART JOURNAL, 2009, 158 (02) : 302 - 308
  • [40] Successful Transapical Aortic Valve Implantation in a Congenital Bicuspid Aortic Valve
    Ferrari, Enrico
    Locca, Didier
    Sulzer, Christopher
    Marcucci, Carlo
    Rizzo, Elena
    Tozzi, Piergiorgio
    von Segesser, Ludwig K.
    ANNALS OF THORACIC SURGERY, 2010, 90 (02): : 630 - 632