Extinction Limit of Diesel Pool Fires Suppressed by Water Mist

被引:12
|
作者
Cong Beihua [1 ,2 ]
Liao Guangxuan [2 ]
Huang Zhen [1 ]
机构
[1] Shanghai Jiao Tong Univ, Minist Educ, Key Lab Power Mach & Engn, Shanghai 200030, Peoples R China
[2] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
关键词
water mist; diesel pool fires; extinction limit; fire suppression and intensification;
D O I
10.1177/0734904108095337
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work describes an experimental and theoretical investigation of extinction limit of diesel pool fires suppressed by water mist. A downward-directed nozzle produced a fine water spray over small-scale opposed diesel pool fires. The fire extinction limit is obtained from minimum nozzle injection pressure or maximum fire size when the fire extinguishment took place. For the conditions tested, it is observed that there are two distinct regions in the relationship between the injection pressure and fire size, i.e., a fire suppression region and a fire intensification region. The transition of the two regions is dependent on the effective water flux and the plume-spray thrust ratio. It is also revealed that the fuel surface cooling is the dominant mechanism for diesel pool fires at extinction limit in the tests. The failure to cause fire extinction is mainly due to the insufficient water flux applied to remove enough heat from the fuel surface.
引用
收藏
页码:5 / 26
页数:22
相关论文
共 50 条
  • [31] Water Mist Extinguishment of Horizontal Exhaust Duct Fires
    Hong-Zeng Yu
    Fire Technology, 2022, 58 : 1333 - 1362
  • [32] Fire suppression mechanisms of solid fires with water mist
    State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230026, China
    Ranshao Kexue Yu Jishu, 2007, 1 (40-44):
  • [33] Numerical studies on extinguishing solid fires by water mist
    Cong, B.
    Liao, G.
    Yao, B.
    Qin, J.
    Chow, W.
    Journal of Applied Fire Science, 2008, 18 (03): : 241 - 270
  • [34] A review on studying extinguishing room fires by water mist
    Chow, W.K.
    Li, Y.F.
    Journal of Applied Fire Science, 2002, 11 (04): : 367 - 403
  • [35] Preliminary burning tests on PVC fires with water mist
    Liu, YM
    Yao, B
    Qin, J
    POLYMER TESTING, 2005, 24 (05) : 583 - 587
  • [36] A numerical study of water mist mitigation of tunnel fires
    Nmira, F.
    Consalvi, J. L.
    Kaiss, A.
    Fernandez-Pello, A. C.
    Porterie, B.
    FIRE SAFETY JOURNAL, 2009, 44 (02) : 198 - 211
  • [37] Water Mist Extinguishment of Horizontal Exhaust Duct Fires
    Yu, Hong-Zeng
    FIRE TECHNOLOGY, 2022, 58 (03) : 1333 - 1362
  • [38] The effects of droplet size and injection orientation on water mist suppression of low and high boiling point liquid pool fires
    Ndubizu, CC
    Ananth, R
    Tatem, PA
    COMBUSTION SCIENCE AND TECHNOLOGY, 2000, 157 (1-6) : 63 - +
  • [39] Experimental and numerical study on attenuation of thermal radiation from large-scale pool fires by water mist curtain
    Zhu, Pei
    Wang, Xishi
    Wang, Zhigang
    Cong, Haiyong
    Ni, Xiaomin
    JOURNAL OF FIRE SCIENCES, 2015, 33 (04) : 269 - 289
  • [40] EXTINCTION OF FIRES IN LIQUIDS BY COOLING WITH WATER SPRAYS
    RASBASH, DJ
    ROGOWSKI, ZW
    COMBUSTION AND FLAME, 1957, 1 (04) : 453 - 466