Adjustable versus non-adjustable sutures for strabismus

被引:9
|
作者
Haridas, Anjana [1 ]
Sundaram, Venki [1 ]
机构
[1] Univ London London Sch Hyg & Trop Med, ICEH, Cochrane Eyes & Vis Grp, London WC1E 7HT, England
关键词
Suture Techniques; Strabismus [surgery; Humans; SURGERY;
D O I
10.1002/14651858.CD004240.pub3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Strabismus, or squint, can be defined as a deviation from perfect ocular alignment and can be classified in many ways according to its aetiology and presentation. Treatment can be broadly divided into medical and surgical options, with a variety of surgical techniques being available, including the use of adjustable or non-adjustable sutures for the extraocular muscles. There exists an uncertainty as to which of these techniques produces a better surgical outcome, and also an opinion that the adjustable suture technique may be of greater benefit in certain situations. Objectives To examine whether adjustable or non-adjustable sutures are associated with a more accurate long-term ocular alignment following strabismus surgery and to identify any specific situations in which it would be of benefit to use a particular method. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE, (January 1950 to January 2013), EMBASE (January 1980 to January 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (http://clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 17 January 2013. We also contacted experts in the field for further information. Selection criteria We planned to include only randomised controlled trials (RCTs) comparing adjustable to non-adjustable sutures for strabismus surgery. Data collection and analysis We did not find any studies that met the inclusion criteria for this review. Main results We did not find any studies that met the inclusion criteria for this review, therefore none were included for analysis. Results of non-randomised studies that compared these techniques are reported. Authors' conclusions No reliable conclusions could be reached regarding which technique (adjustable or non-adjustable sutures) produces a more accurate long-term ocular alignment following strabismus surgery or in which specific situations one technique is of greater benefit than the other. High quality RCTs are needed to obtain clinically valid results and to clarify these issues. Such trials should ideally a) recruit participants with any type of strabismus or specify the subgroup of participants to be studied, for example, thyroid, paralytic, non-paralytic, paediatric; b) randomise all consenting participants to have either adjustable or non-adjustable surgery prospectively; c) have at least six months of follow-up data; and d) include re-operation rates as a primary outcome measure.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Combined cataract and strabismus surgery with adjustable sutures - Reply
    Ticho, Benjamin H.
    JOURNAL OF AAPOS, 2007, 11 (01): : 73 - 73
  • [32] The use of subtenon ropivacaine in managing strabismus with adjustable sutures
    Walters, G
    Stewart, OG
    Bradbury, JA
    JOURNAL OF AAPOS, 2001, 5 (02): : 95 - 97
  • [33] Utility of Adjustable Sutures in Primary Strabismus Surgery and Reoperations
    Mireskandari, Kamiar
    Cotesta, Melissa
    Schofield, Jennifer
    Kraft, Stephen P.
    OPHTHALMOLOGY, 2012, 119 (03) : 629 - 633
  • [34] ADJUSTABLE SUTURES IN STRABISMUS SURGERY - A PERSONAL SERIES OF CASES
    AGNELLO, R
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1986, 14 (02): : 143 - 153
  • [35] VAGAL RESPONSES TO ADJUSTABLE SUTURES IN STRABISMUS CORRECTION - REPLY
    EUSTIS, HS
    EISWORTH, CC
    SMITH, DR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (01) : 125 - 126
  • [36] Current status of non-adjustable gastric banding
    Fried, M
    Kasalicky, M
    Melechovsky, D
    Kormanova, K
    OBESITY SURGERY, 2002, 12 (03) : 395 - 398
  • [37] Current Status of Non-adjustable Gastric Banding
    Martin Fried
    Mojmir Kasalicky
    David Melechovsky
    Karin Kormanova
    Obesity Surgery, 2002, 12 : 395 - 398
  • [38] Adjustable Sutures in the Treatment of Strabismus A Report by the American Academy of Ophthalmology
    Heidary, Gena
    Aakalu, Vinay K.
    Binenbaum, Gil
    Chang, Melinda Y.
    Morrison, David G.
    VanderVeen, Deborah K.
    Lambert, Scott R.
    Trivedi, Rupal H.
    Galvin, Jennifer A.
    Pineles, Stacy L.
    OPHTHALMOLOGY, 2022, 129 (01) : 100 - 110
  • [39] ADJUSTABLE SUTURES IN STRABISMUS SURGERY - A FOLLOW-UP-STUDY
    LENNERSTRAND, G
    ACTA OPHTHALMOLOGICA, 1982, 60 (05): : 717 - 728
  • [40] Adjustable Balloons for Weight Loss: A Higher Yield of Responders Compared With Non-Adjustable Balloons
    Machytka, Evzen
    Divi, Valenti Puig
    Saenger, Fernando
    Sorio, Ricardo
    Brooks, Jeffrey
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (05) : AB495 - AB495