Assessment of Radiation Exposure Dose for Nuclear Medicine Workers from 18F-FDG, 99mTc MDP, and 99mTc

被引:4
|
作者
Al-esaei, Abdulrahman M. [1 ]
Khalil, Magdy M. [5 ,6 ]
El Shazly, Raed M. [1 ]
Kany, Amr M. I. [1 ]
Saleh, Emran Eisa [2 ,3 ,7 ,8 ]
Elmaghraby, Sharif [4 ]
机构
[1] Al Azhar Univ, Fac Sci, Dept Phys, Cairo, Egypt
[2] Univ Aden, Fac Sci, Dept Phys, Aden, Yemen
[3] Ain Shams Univ, Fac Sci, Phys Dept, Cairo, Egypt
[4] Cairo Univ, Fac Med, Dept Oncol, Giza, Egypt
[5] Badr Univ Cairo, Sch Biotechnol, Cairo, Egypt
[6] Helwan Univ, Fac Sci, Dept Phys, Helwan, Cairo, Egypt
[7] Univ Aden, Fac Sci, Phys Dept, Aden, Yemen
[8] Ain Shams Univ, Fac Sci, Phys Dept, Cairo, Egypt
关键词
Nuclear medicine; PET; CT; Tc-99; radiation dose; patients; F18-FDG; PET;
D O I
10.2174/1874471015666220413114927
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Nuclear medicine or diagnostic radiology personnel are always exposed to low-level radiation from radionuclides used in medical diagnostics, which lead to potential biological hazards or effects. Objective: External exposure for workers in two nuclear medicine centers was measured by recruiting 120 patients. Methods: Three nuclear medicine examinations were performed using F18-FDG PET/CT, Tc-99m-MDP bones scan, and Tc-99m thyroid scan by a digital radiation dosimeter. Results: The average received accumulative radiation dose for workers was found to be 0.838 +/- 0.17, 0.527 +/- 0.11, and 0.270 +/- 0.05 mu Sv for F18-FDG PET/CT, Tc-99m-MDP bones scan, and Tc-99m thyroid scan, respectively. The annual effective dose for workers was estimated to be 2.09 +/- 0.42, 1.34 +/- 0.27, and 0.68 +/- 0.14 mSv, respectively. Moreover, the average patient-to-staff dose coefficients were found to be 0.024 +/- 0.005, 0.003 +/- 0.001, and 0.007 +/- 0.002 mu Sv m(2)/MBq h for F18-FDG PET/CT, Tc-99m-MDP bones scan, and Tc-99m thyroid scan, respectively. Conclusion: It is clear from the results that the radiation doses received by workers during the nuclear medicine imaging examinations were less than the doses recommended by the International Commission on Radiological Protection (ICRP) for such examinations.
引用
收藏
页码:320 / 326
页数:7
相关论文
共 50 条
  • [41] Incidental 99mTc MDP uptake in the intestines and intravenous CT contrast
    Kim, Soo J.
    Choi, Joon Y.
    Lee, Joo H.
    Hyun, Seung H.
    Cho, Young S.
    Moon, Seung H.
    Choe, Yearn S.
    Lee, Kyung-Han
    Kim, Byung-Tae
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2016, 55 (04): : 166 - 171
  • [42] 99mTc—MDP软组织显像一例
    单丽萍
    王刚
    周艳丽
    内蒙古医学杂志, 2004, (10) : 788 - 788
  • [43] Unexpected Pyelonephritis Incidentally Revealed on 99mTc MDP Bone Scintigraphy
    Zhao, Xiaofei
    Zhao, Ruifang
    Wu, Ha
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (12) : 978 - 979
  • [44] Assessment of radionuclidic impurities in cyclotron produced 99mTc
    Lebeda, Ondrej
    van Lier, Erik J.
    Stursa, Jan
    Ralis, Jan
    Zyuzin, Alexander
    NUCLEAR MEDICINE AND BIOLOGY, 2012, 39 (08) : 1286 - 1291
  • [45] Comprehensive functional evaluation of the spectrum of progressive nuclear palsy with 18F-FDG PET/CT and 99MTC TRODAT-1 SPECT
    Verma, Ritu
    Ranjan, Rajeev
    Seniaray, Nikhil
    Belho, Ethel
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2021, 429 : 338 - 339
  • [46] Implementing [18F]fluorocholine PET/CT leads to a reduced effective patient dose compared to standard [99mTc]-sestamibi and [99mTc]-pertechnetate scintigraphy SPECT/CT
    Rode, M.
    Moeller, H. Reilev
    Oestergaard, L. Lange
    Holdgaard, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S311 - S311
  • [47] Nanotamoxifen as a Therapeutic Option: Assessment by Labeling With 99mTc
    Shukla, J.
    Arora, G.
    Bandopadhyaya, G. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S336 - S337
  • [48] Designing of sophisticated automatic lead shielding to reduce radiation dose of 99mTc
    Zia, Najama
    Fakhar-E-Alam, M.
    Atif, M.
    Farooq, W. A.
    Aziz, M. Hammad
    Nadeem, Afzal
    Shad, Naveed Akhtar
    Zia-Ul-Haq
    Baig, M. R.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2014, 16 (3-4): : 443 - 450
  • [49] HYNIC a bifunctional prosthetic group for the labelling of peptides with 99mTc and 18FDG
    Sepideh Khoshbakht
    Farzad Kobarfard
    Davood Beiki
    Omid Sabzevari
    Mohsen Amini
    Faramarz Mehrnejad
    Kimia Tabib
    Soraya Shahhosseini
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 1125 - 1134
  • [50] Diagnostic value of 18F-FDG PET in the assessment of myocardial viability in coronary artery disease: A comparative study with 99mTc SPECT and echocardiography
    Al Moudi, Mansour
    Sun, Zhong-Hua
    JOURNAL OF GERIATRIC CARDIOLOGY, 2014, 11 (03) : 229 - 236