Esophageal temperature during radiofrequency-catheter ablation of left atrium: A three-dimensional computer modeling study

被引:28
|
作者
Hornero, F
Berjano, EJ
机构
[1] Univ Polytecn Valencia, Ctr Res & Innovat Bioengn, Valencia 46022, Spain
[2] Univ Valencia, Gen Hosp, Dept Cardiac Surg, E-46003 Valencia, Spain
关键词
computer model; esophagus; left atrium; radiofrequency ablation;
D O I
10.1111/j.1540-8167.2006.00404.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Modeling for Esophageal Temperature Evolution. Introduction: There is current interest in finding a way to minimize thermal injury in the esophagus during radiofrequency-catheter ablation of the left atrium. Despite the fact that the esophageal temperature is now being monitored during ablation, the influence of different anatomic and technical factors on the temperature rise remains unknown. Methods and Results: We implemented a three-dimensional computational model that included atrial tissue, epicardial fat, esophagus, aorta, and lung, all linked by connective tissue. The finite-element method was used to calculate the esophageal temperature distribution during a procedure of constant-temperature ablation with an 8-mm electrode, under different tissue conditions. Results showed that the distance between electrode and esophagus was the most important anatomic factor in predicting the esophageal temperature rise, the composition of the different tissues being of lesser importance. The measurement of the esophageal temperature in different sites of the lumen offered differences up to 3.7 degrees C, especially for a short electrode-esophagus distance (5 mm). The difference in the convective cooling by circulating blood around electrode and endocardium did not show a significant influence on the esophageal temperature rise. Conclusion: Computer results suggest that (1) the electrode-esophagus distance is the most important anatomic factor; (2) the incorrect positioning of an esophageal temperature probe could give a low reading for the maximum temperature reached in the esophagus; and (3) the different cooling effect of the circulating blood flow at different atrial sites has little impact on the esophageal temperature rise.
引用
收藏
页码:405 / 410
页数:6
相关论文
共 50 条
  • [21] What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis
    Berjano, EJ
    Hornero, F
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) : 837 - 848
  • [22] Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: Implications for catheter ablation of atrial fibrillation
    Malchano, Zachary J.
    Neuzil, Petr
    Cury, Ricardo C.
    Holmvang, Godtfred
    Weichet, Jiri
    Schmidt, Ehud J.
    Ruskin, Jeremy N.
    Reddy, Vivek Y.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (11) : 1221 - 1229
  • [23] Virtual ablation for atrial fibrillation in personalized in-silico three-dimensional left atrial modeling: Comparison with clinical catheter ablation
    Hwang, Minki
    Kwon, Soon-Sung
    Wi, Jin
    Park, Mijin
    Lee, Hyun-Seung
    Park, Jin-Seo
    Lee, Young-Seon
    Shim, Eun Bo
    Pak, Hui-Nam
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2014, 116 (01): : 40 - 47
  • [24] Use of three-dimensional catheter guidance and trans-esophageal echocardiography to eliminate fluoroscopy in catheter ablation of left-sided accessory pathways
    Clark, John
    Bockoven, J. R.
    Lane, John
    Patel, C. R.
    Smith, Grace
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (03): : 283 - 289
  • [25] Combined use of three-dimensional rotational angiogram of left atrium and circular multi-electrode ablation catheter for pulmonary vein isolation
    Charalampos Kriatselis
    Sotiris Nedios
    Mathias Roser
    Stephan Goetze
    Eckard Fleck
    Jin-Hong Gerds-Li
    中华医学杂志(英文版), 2012, (01) : 144 - 148
  • [26] Combined use of three-dimensional rotational angiogram of left atrium and circular multi-electrode ablation catheter for pulmonary vein isolation
    Tang Min
    Kriatselis, Charalampos
    Nedios, Sotiris
    Roser, Mathias
    Goetze, Stephan
    Fleck, Eckard
    Gerds-Li, Jin-Hong
    CHINESE MEDICAL JOURNAL, 2012, 125 (01) : 144 - 148
  • [27] Three-dimensional rotational angiography of the left atrium during adenosine-induced asystole: relevance for pulmonary vein ablation
    Kriatselis, C.
    Tang, M.
    Roser, M.
    Gerds-Li, H.
    Fleck, E.
    EUROPEAN HEART JOURNAL, 2008, 29 : 290 - 290
  • [28] Different Responses of Left Atrium and Left Atrial Appendage to Radiofrequency Catheter Ablation of Atrial Fibrillation: a Follow Up MRI study
    Yun Gi Kim
    Jaemin Shim
    Suk-Kyu Oh
    Hee-Soon Park
    Kwang-No Lee
    Sung Ho Hwang
    Jong-Il Choi
    Young-Hoon Kim
    Scientific Reports, 8
  • [29] Different Responses of Left Atrium and Left Atrial Appendage to Radiofrequency Catheter Ablation of Atrial Fibrillation: a Follow Up MRI study
    Kim, Yun Gi
    Shim, Jaemin
    Oh, Suk-Kyu
    Park, Hee-Soon
    Lee, Kwang-No
    Hwang, Sung Ho
    Choi, Jong-Il
    Kim, Young-Hoon
    SCIENTIFIC REPORTS, 2018, 8
  • [30] Fate of left atrial function as determined by real-time three-dimensional echocardiography study after radiofrequency catheter ablation for the treatment of atrial fibrillation
    Delgado, Victoria
    Vidal, Barbara
    Sitges, Marta
    Tamborero, David
    Mont, Lluis
    Berruezo, Antonio
    Azqueta, Manuel
    Pare, Carles
    Brugada, Josep
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (09): : 1285 - 1290