Controller for an axial flow blood pump

被引:50
|
作者
Konishi, H
Antaki, JF
Amin, DV
Boston, JR
Kerrigan, JP
Mandarino, WA
Litwak, P
Yamazaki, K
Macha, M
Butler, KC
Borovetz, HS
Kormos, RL
机构
[1] UNIV PITTSBURGH,MED CTR,PRESBYTERIAN UNIV HOSP,DIV CARDIOTHORAC SURG,PITTSBURGH,PA 15213
[2] UNIV PITTSBURGH,SCH MED,ARTIFICIAL HEART & LUNG PROGRAM,PITTSBURGH,PA
[3] UNIV PITTSBURGH,SCH ENGN,ARTIFICIAL HEART & LUNG PROGRAM,PITTSBURGH,PA
[4] NIMBUS INC,RANCHO CORDOVA,CA
关键词
axial flow blood pump; noninvasive pump regulation;
D O I
10.1111/j.1525-1594.1996.tb04491.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A rotary blood pump inherently provides only one noninvasive ''observable'' parameter (motor current) and allows for only one ''controllable'' parameter (pump speed). To maintain the systemic circulation properly, the pump speed must be controlled to sustain appropriate outlet flows and perfusion pressure while preventing pulmonary damage caused by extremes in preload. Steady-state data were collected at repeated intervals during chronic trials of the Nimbus AxiPump (Nimbus, Inc., Rancho Cordova, California, U.S.A.) in sheep (n = 7) and calves (n = 12). For each data set, the pump speed was increased at increments of 500 rpm until left ventricular and left atrial emptying was observed by left atrial pressure diminishing to zero. The effect of decreasing preload was evaluated perioperatively by inferior vena cava occlusion at a constant pump speed. Fourier analysis established a relationship between changes in the pump preload and the power spectra of the pump current waveform. Based on these results, a control method was devised to avoid ventricular collapse and maintain the preload within a physiologic range. The objective of this controller is the minimization of the second and third harmonic of the periodic current waveform. This method is intended to provide a noninvasive regulation of the pump by eliminating the need for extraneous transducers.
引用
收藏
页码:618 / 620
页数:3
相关论文
共 50 条
  • [21] A mechanically non-contact axial flow blood pump
    不详
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 878 - 878
  • [22] Sealing properties of mechanical seals for an axial flow blood pump
    Tomioka, J
    Mori, T
    Yamazaki, K
    Koyanagi, H
    [J]. ARTIFICIAL ORGANS, 1999, 23 (08) : 708 - 711
  • [23] Mechanical axial flow blood pump to support cavopulmonary circulation
    Throckmorton, A. L.
    Kapadia, J.
    Madduri, D.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (11): : 970 - 982
  • [24] A compact magnetic bearing system for axial flow blood pump
    Lim Tau Meng
    Cheng Shanbao
    Zhang Dongsheng
    [J]. IMECS 2007: INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, VOLS I AND II, 2007, : 1591 - +
  • [25] Unique ECG finding in a patient with an axial blood flow pump
    Jin, XY
    Westaby, S
    Robson, D
    Catarino, P
    Saito, S
    Banning, A
    [J]. CIRCULATION, 2001, 104 (08) : 970 - 971
  • [26] Assessment of Hemolysis in a Ventricular Assist Axial Flow Blood Pump
    Gouskov A.M.
    Lomakin V.O.
    Banin E.P.
    Kuleshova M.S.
    [J]. Biomedical Engineering, 2016, 50 (4) : 233 - 236
  • [27] Simulation of Blood Flow Dynamics Changes through Implantable Axial Flow Pump
    Petukhov D.S.
    Telyshev D.V.
    [J]. Biomedical Engineering, 2015, 48 (6) : 336 - 340
  • [28] Development of an axial flow blood pump: Characteristics of a magnetic fluid seal
    Sekine K.
    Asakawa M.
    Mitamura Y.
    [J]. Journal of Artificial Organs, 2001, 4 (3) : 245 - 251
  • [29] Proposal of hemodynamically improved design of an axial flow blood pump for LVAD
    Vikas Kannojiya
    Arup Kumar Das
    Prasanta Kumar Das
    [J]. Medical & Biological Engineering & Computing, 2020, 58 : 401 - 418
  • [30] The Discrete-Continuous, Global Optimisation of an Axial Flow Blood Pump
    Krzysztof Tesch
    Katarzyna Kaczorowska-Ditrich
    [J]. Flow, Turbulence and Combustion, 2020, 104 : 777 - 793