Levels and health risk assessments of particulate matters (PM2.5 and PM10) in indoor/outdoor air of waterpipe cafes in Tehran, Iran

被引:47
|
作者
Heydari, Gholamreza [1 ]
Taghizdeh, Farhad [2 ]
Fazlzadeh, Mehdi [3 ,4 ]
Jafari, Ahmad Jonidi [2 ,5 ]
Asadgol, Zahra [2 ]
Mehrizi, Ehsan Abouee [2 ,6 ]
Moradi, Masoud [7 ]
Arfaeinia, Hossein [8 ,9 ]
机构
[1] Shahid Beheshti Univ Med Sci, Natl Res Inst TB & Lung Dis, Tobacco Prevent & Control Res Ctr, Tehran, Iran
[2] Iran Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[3] Ardabil Univ Med Sci, Social Determinants Hlth Res Ctr, Ardebil, Iran
[4] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[5] Iran Univ Med Sci, Res Ctr Environm Hlth Technol, Tehran, Iran
[6] Shahid Sadoughi Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Yazd, Iran
[7] Kermanshah Univ Med Sci, Res Ctr Environm Determinants Hlth, Kermanshah, Iran
[8] Bushehr Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Bushehr, Iran
[9] Bushehr Univ Med Sci, Persian Gulf Biomed Sci Res Inst, Syst Environm Hlth & Energy Res Ctr, Bushehr, Iran
关键词
Air quality; PM2.5; PM10; Waterpipe cafes; Risk assessment; Tehran; INDOOR AIR; SMOKING; BTEX; TOBACCO; PIPE;
D O I
10.1007/s11356-019-04202-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the concentration of particulate matters (PM2.5 and PM10), 36 samples were collected from indoor/outdoor air of hookah cafes (HS), cigarette cafes (CS), both hookah and cigarette (HCS), and no-smoking building (NS) in Tehran City from December 2017 to March 2018. The mean +/- SD of PM10 concentration in the indoor air of the cafes in terms of HS, CS, HCS, and NS sites has been 702.35, 220.20, 1156.60, and 60.12g/m(3), while for PM2.5, the values have been 271.92, 111.80, 619.10, and 22.25g/m(3), respectively. It was also found that the PM concentration inside the cafes was higher during weekend session (with a higher number of active smokers), than during the weekday sessions. Moreover, the PM levels in the indoor air of the cafes were considerably higher than those of the outdoors (p<0.05). Based on path analysis, the number of active smokers had the highest influence on production of PM inside the cafes, followed by the tobacco type. Finally, the mean excess lifetime cancer risk (ELCR) for PM2.5 in the indoor air of cafes was observed in the range of 0.64x10(-5)-14.98x10(-5). Also, the mean of hazard quotient (HQ) for PM2.5 and PM10 was calculated in range of 0.82-18.4 and 0.16-3.28, respectively, which corresponds to an unacceptably high risk for human health. The PM levels in the indoor air of smoking cafes in Tehran are significantly high, such that it can cause serious risks for the health of both the customers and personnel. Thus, it is necessary that suitable controlling strategies be adopted for this public health threat.
引用
收藏
页码:7205 / 7215
页数:11
相关论文
共 50 条
  • [41] Health risk assessment of heavy metals in PM2.5 and PM10 in Sarajevo air, Bosnia and Herzegovina
    Trako, Nejira
    Masic, Ferida
    Ajanovic, Faruk
    Merdan, Samra
    Huremovic, Jasna
    Zero, Sabina
    Masic, Adnan
    Gojak-Salimovic, Sabina
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2023, 58 (13): : 1039 - 1045
  • [42] Correlation of ambient particulate matters (PM10, PM2.5) with respiratory hospital admissions: a case-crossover study in Urmia, Iran
    Shakerkhatibi, Mohammad
    Seifipour, Hajar
    Sabeti, Zahra
    Kahe, Danian
    Asghari Jafarabadi, Mohammad
    Zoroufchi Benis, Khaled
    Hajaghazadeh, Mohammad
    HUMAN AND ECOLOGICAL RISK ASSESSMENT, 2021, 27 (08): : 2184 - 2201
  • [43] Assessment of ambient air PM10 and PM2.5 and characterization of PM10 in the city of Kanpur, India
    Sharma, M
    Maloo, S
    ATMOSPHERIC ENVIRONMENT, 2005, 39 (33) : 6015 - 6026
  • [44] Influences of wind and precipitation on different-sized particulate matter concentrations (PM2.5, PM10, PM2.5–10)
    Boen Zhang
    Limin Jiao
    Gang Xu
    Suli Zhao
    Xin Tang
    Yue Zhou
    Chen Gong
    Meteorology and Atmospheric Physics, 2018, 130 : 383 - 392
  • [45] Characterization of PAHs and metals in indoor/outdoor PM10/PM2.5/PM1 in a retirement home and a school dormitory
    Hassanvand, Mohammad Sadegh
    Naddafi, Kazem
    Faridi, Sasan
    Nabizadeh, Ramin
    Sowlat, Mohammad Hossein
    Momeniha, Fatemeh
    Gholampour, Akbar
    Arhami, Mohammad
    Kashani, Homa
    Zare, Ahad
    Niazi, Sadegh
    Rastkari, Noushin
    Nazmara, Shahrokh
    Ghani, Maryam
    Yunesian, Masud
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 527 : 100 - 110
  • [46] Indoor and outdoor particulate matter (PM2.5 and PM10) concentrations in classrooms in Umm Al-Qura University, Makkah, Saudi Arabia
    Khalafalla, Mutasim Mohamed
    Pasha, Tariq Sultan Ul haq
    BIOSCIENCE RESEARCH, 2023, 20 (01): : 232 - 238
  • [47] Exposure to high levels of PM2.5 and PM10 in the metropolis of Tehran and the associated health risks during 2016-2017
    Yunesian, Masud
    Rostami, Roohollah
    Zarei, Ahmad
    Fazlzadeh, Mehdi
    Janjani, Hosna
    MICROCHEMICAL JOURNAL, 2019, 150
  • [48] Sources of PM10 and PM2.5 in Cairo's ambient air
    Abu-Allaban, M.
    Lowenthal, D. H.
    Gertler, A. W.
    Labib, M.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 133 (1-3) : 417 - 425
  • [49] The Effect of Meteorological Conditions on PM10 and PM2.5 Pollution of the Air
    Radzka, Elzbieta
    Rymuza, Katarzyna
    ROCZNIK OCHRONA SRODOWISKA, 2019, 21 (01): : 611 - 628
  • [50] Sources of PM10 and PM2.5 in Cairo’s ambient air
    M. Abu-Allaban
    D. H. Lowenthal
    A. W. Gertler
    M. Labib
    Environmental Monitoring and Assessment, 2007, 133 : 417 - 425