Levels and health risk assessments of particulate matters (PM2.5 and PM10) in indoor/outdoor air of waterpipe cafes in Tehran, Iran

被引:47
|
作者
Heydari, Gholamreza [1 ]
Taghizdeh, Farhad [2 ]
Fazlzadeh, Mehdi [3 ,4 ]
Jafari, Ahmad Jonidi [2 ,5 ]
Asadgol, Zahra [2 ]
Mehrizi, Ehsan Abouee [2 ,6 ]
Moradi, Masoud [7 ]
Arfaeinia, Hossein [8 ,9 ]
机构
[1] Shahid Beheshti Univ Med Sci, Natl Res Inst TB & Lung Dis, Tobacco Prevent & Control Res Ctr, Tehran, Iran
[2] Iran Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[3] Ardabil Univ Med Sci, Social Determinants Hlth Res Ctr, Ardebil, Iran
[4] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[5] Iran Univ Med Sci, Res Ctr Environm Hlth Technol, Tehran, Iran
[6] Shahid Sadoughi Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Yazd, Iran
[7] Kermanshah Univ Med Sci, Res Ctr Environm Determinants Hlth, Kermanshah, Iran
[8] Bushehr Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Bushehr, Iran
[9] Bushehr Univ Med Sci, Persian Gulf Biomed Sci Res Inst, Syst Environm Hlth & Energy Res Ctr, Bushehr, Iran
关键词
Air quality; PM2.5; PM10; Waterpipe cafes; Risk assessment; Tehran; INDOOR AIR; SMOKING; BTEX; TOBACCO; PIPE;
D O I
10.1007/s11356-019-04202-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the concentration of particulate matters (PM2.5 and PM10), 36 samples were collected from indoor/outdoor air of hookah cafes (HS), cigarette cafes (CS), both hookah and cigarette (HCS), and no-smoking building (NS) in Tehran City from December 2017 to March 2018. The mean +/- SD of PM10 concentration in the indoor air of the cafes in terms of HS, CS, HCS, and NS sites has been 702.35, 220.20, 1156.60, and 60.12g/m(3), while for PM2.5, the values have been 271.92, 111.80, 619.10, and 22.25g/m(3), respectively. It was also found that the PM concentration inside the cafes was higher during weekend session (with a higher number of active smokers), than during the weekday sessions. Moreover, the PM levels in the indoor air of the cafes were considerably higher than those of the outdoors (p<0.05). Based on path analysis, the number of active smokers had the highest influence on production of PM inside the cafes, followed by the tobacco type. Finally, the mean excess lifetime cancer risk (ELCR) for PM2.5 in the indoor air of cafes was observed in the range of 0.64x10(-5)-14.98x10(-5). Also, the mean of hazard quotient (HQ) for PM2.5 and PM10 was calculated in range of 0.82-18.4 and 0.16-3.28, respectively, which corresponds to an unacceptably high risk for human health. The PM levels in the indoor air of smoking cafes in Tehran are significantly high, such that it can cause serious risks for the health of both the customers and personnel. Thus, it is necessary that suitable controlling strategies be adopted for this public health threat.
引用
收藏
页码:7205 / 7215
页数:11
相关论文
共 50 条
  • [1] Levels and health risk assessments of particulate matters (PM2.5 and PM10) in indoor/outdoor air of waterpipe cafés in Tehran, Iran
    Gholamreza Heydari
    Farhad Taghizdeh
    Mehdi Fazlzadeh
    Ahmad Jonidi Jafari
    Zahra Asadgol
    Ehsan Abouee Mehrizi
    Masoud Moradi
    Hossein Arfaeinia
    Environmental Science and Pollution Research, 2019, 26 : 7205 - 7215
  • [2] INDOOR PM1, PM2.5, PM10 AND OUTDOOR PM2.5 CONCENTRATIONS IN PRIMARY SCHOOLS IN SARI, IRAN
    Mohammadyan, Mahmoud
    Shabankhani, Bijan
    ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2013, 64 (03): : 371 - 377
  • [3] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    Tsai, FC
    Smith, KR
    Vichit-Vadakan, N
    Ostro, BD
    Chestnut, LG
    Kungskulniti, N
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (01): : 15 - 26
  • [4] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    FENG C TSAI
    KIRK R SMITH
    NUNTAVARN VICHIT-VADAKAN
    BART D OSTRO
    LAURAINE G CHESTNUT
    NIPAPUN KUNGSKULNITI
    Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 15 - 26
  • [5] Indoor and outdoor PM2.5 and PM10 concentrations in the air during a dust storm
    Kuo, Hsien-Wen
    Shen, Huna-Yi
    BUILDING AND ENVIRONMENT, 2010, 45 (03) : 610 - 614
  • [6] Chemical Characterization of Indoor and Outdoor Particulate Matter (PM2.5, PM10) in Doha, Qatar
    Saraga, Dikaia
    Maggos, Thomas
    Sadoun, Eman
    Fthenou, Eleni
    Hassan, Hala
    Tsiouri, Vasiliki
    Karavoltsos, Sotirios
    Sakellari, Aikaterini
    Vasilakos, Christos
    Kakosimos, Konstantinos
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (05) : 1156 - 1168
  • [7] Indoor air concentrations of particulate matter (PM10 and PM2.5) in German schools
    Fromme, H.
    Dietrich, S.
    Twardella, D.
    Heitmann, D.
    Schierl, R.
    Kiranoglu, M.
    Liebl, B.
    Air Pollution XIV, 2006, 86 : 393 - 399
  • [8] The contribution of outdoor particulate matter (PM1, PM2.5, PM10) to school indoor environment
    Zwozdziak, A.
    Sowka, I.
    Worobiec, A.
    Zwozdziak, J.
    Nych, A.
    INDOOR AND BUILT ENVIRONMENT, 2015, 24 (08) : 1038 - 1047
  • [9] Comfort Parameters and Particulate Matter (PM10 and PM2.5) in School Classrooms and Outdoor Air
    Alves, Celia
    Nunes, Teresa
    Silva, Joana
    Duarte, Marcio
    AEROSOL AND AIR QUALITY RESEARCH, 2013, 13 (05) : 1521 - 1535
  • [10] Air Pollution by Fraction Particulate Matters PM10, PM2.5 in the Site of Algiers Centers
    Yahiaoui, F.
    Benrachedi, K.
    Belamri, M.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (03) : 1033 - 1037