CONSIDERATIONS IN THE PRACTICAL APPLICATION OF THE MULTISENSOR CONDUCTIVITY PROBE FOR TWO-PHASE FLOW

被引:3
|
作者
Bernard, Matt [1 ]
Worosz, Ted [1 ]
Kim, Seungjin [1 ]
Hoxie, Chris [2 ]
机构
[1] Penn State Univ, Dept Mech & Nucl Engn, University Pk, PA 16802 USA
[2] US Nucl Regulatory Commiss, Rockville, MD 20852 USA
关键词
conductivity probe; two-phase flow; sensitivity; INTERFACIAL AREA CONCENTRATION; BUBBLY FLOW; PARAMETERS;
D O I
10.13182/NT14-70
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study investigates two issues in the practical application of the local conductivity probe for two-phase flow measurements. First, the effects of signal "ghosting," an electrical interference inherent to multiplexing data acquisition systems, on the measured two-phase flow parameters are examined. A revised conductivity probe circuit is proposed to remove the effects of ghosting. The characteristics of signal ghosting are investigated experimentally with a specialized conductivity probe that enables concurrent acquisition of ghosted and unghosted signals within the same flow condition. It is demonstrated that ghosting causes bubble velocity measurements that are artificially high and, consequently, artificially low interfacial area concentration measurements that depend on sampling frequency and sensor impedance. The revised circuit successfully eliminates this variability. Second, the sensitivity of measured two-phase flow parameters to increasing data acquisition sampling frequency is investigated experimentally. Measurements are acquired at incrementally increasing sampling frequencies with a four-sensor conductivity probe in 13 vertical-upward air-water two-phase flow conditions with superficial liquid and gas velocities ranging from 1.00 to 5.00 m/s and 0.17 to 2.0 m/s, respectively. It is found that the void fraction and average bubble velocity are insensitive to the sampling frequency, while the detected number of bubbles and interfacial area concentration can demonstrate a strong dependence. Considerations for selecting appropriate sampling frequencies in different flow conditions are discussed.
引用
下载
收藏
页码:225 / 235
页数:11
相关论文
共 50 条
  • [31] Two-phase microfluid flow based on AC electric field and conductivity gradient
    Jiang, Hong-Yuan
    Ren, Yu-Kun
    Ramos, A.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2011, 43 (02): : 109 - 113
  • [32] TWO-PHASE LOW CONDUCTIVITY FLOW IMAGING USING MAGNETIC INDUCTION TOMOGRAPHY
    Wei, H. -Y.
    Soleimani, M.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2012, 131 : 99 - 115
  • [33] Application of Equidensitometry for Diagnosis of a Two-Phase Flow and a Flow of Low Density.
    Schweiger, G.
    Wanders, K.
    Wiegand, H.
    1600, : 73 - 2
  • [34] Application of oscillation flow to horizontal gas-particle two-phase flow
    Dong, Lin
    Ding, Mingjie
    Rinoshika, Akira
    Wang, Yongli
    Yuan, Chunping
    POWDER TECHNOLOGY, 2022, 406
  • [35] In search of two-phase flow
    Hewitt, GF
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 518 - 527
  • [36] Managing two-phase flow
    不详
    TCE, 2004, (760): : 22 - 22
  • [37] IVESTIGATION OF TWO-PHASE FLOW
    Otahal, Jan
    EXPERIMENTAL FLUID MECHANICS 2008, PROCEEDINGS, 2008, : 13 - 20
  • [38] Turbulent two-phase flow
    vanWijngaarden, L
    ADVANCES IN TURBULENCES VI, 1996, 36 : 535 - 541
  • [39] Two-phase flow patterns
    Marshall, Rebekkah
    CHEMICAL ENGINEERING, 2006, 113 (12) : 55 - 55
  • [40] Two-phase flow in microchannels
    Serizawa, A
    Feng, ZP
    Kawara, Z
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2002, 26 (6-7) : 703 - 714