Energy efficiency of wastewater treatment plant through aeration system

被引:3
|
作者
Aziz, Nurul Farhana Azis [1 ]
Ramli, Nor Azuana [1 ]
Abd Hamid, Mohd Fairuz [1 ]
机构
[1] Univ Kuala Lumpur, Elect Engn Sect, British Malaysian Inst, Batu 8,Jalan Sungai Pusu, Gombak 53100, Selangor, Malaysia
关键词
Wastewater treatment plant; Energy efficiency; Energy management; Aeration system;
D O I
10.5004/dwt.2019.24134
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
High energy consumption affects the wastewater industry especially in our country since the utility bills for sewer services is subsidized by the government. It has been identified as a highest electricity energy contributed to the operational expenditure cost bare by the licensee operator company. Hence, a proper and effective solution is needed to reduce the amount of bill need to be paid by the company by decreasing the consumption of energy during operation. Through the energy audit conducted earlier, the auditor identified that there are several equipment or machine consume high energy. Energy consumption varies considerably between wastewater unit processes and facilities, but several other trends are also exist. Eventually, aeration seem to be proven as an element that consumes more energy compared to the other based on the energy audit report. In order to reduce the energy consumption in the aeration system, High Speed Turbo compressor is proposed to replace the existing roots blower. From the analysis that has been gathered from the case study which has been applied in one of the wastewater treatment plant in Malaysia, through the usage of High Speed Turbo compressor, it has been proven that the energy consumption might reduce up to 42% compared to the usage of roots blower. As per calculation, the expected return of capital expenditure will be within the period of 1.22 y which proved that the proposed system will not only affecting the cost efficiency, but also generates revenue in short period of time.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 50 条
  • [21] Aeration control of a wastewater treatment plant using hybrid NMPC
    Cristea, S.
    de Prada, C.
    Sarabia, D.
    Gutierrez, G.
    COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (04) : 638 - 650
  • [22] Economic Linear Parameter Varying Model Predictive Control of the Aeration System of a Wastewater Treatment Plant
    Nejjari, Fatiha
    Khoury, Boutrous
    Puig, Vicenc
    Quevedo, Joseba
    Pascual, Josep
    de Campos, Sergi
    SENSORS, 2022, 22 (16)
  • [23] OAHU WASTEWATER TREATMENT PLANT EFFICIENCY
    YOUNG, RHF
    CHAN, PL
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1970, 42 (12): : 2052 - &
  • [24] Appliclation of a system with automatic control of aeration time to the intermittent-aeration activated sludge process in an existing wastewater treatment plant
    Hamamoto, Y.
    Ideshita, Y.
    Nonaka, H.
    Proceedings of the International Association on Water Pollution Research and Control (IAWPRC) Workshop, 1990,
  • [25] Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant
    Zhou, Xiaohong
    Wu, Yuanyuan
    Shi, Hanchang
    Song, Yanqing
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2013, 25 (02) : 295 - 301
  • [26] The influence of industrial wastewater on the energy consumption and the efficiency of technological processes in municipal wastewater treatment plant
    Remiszewska-Skwarek, Anna
    Fudala-Ksiazek, Sylwia
    Luczkiewicz, Aneta
    ROCZNIK OCHRONA SRODOWISKA, 2016, 18 : 110 - 121
  • [27] Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant
    Xiaohong Zhou
    Yuanyuan Wu
    Hanchang Shi
    Yanqing Song
    Journal of Environmental Sciences, 2013, 25 (02) : 295 - 301
  • [28] The Enhancement of Energy Efficiency in a Wastewater Treatment Plant through Sustainable Biogas Use: Case Study from Poland
    Maslon, Adam
    Czarnota, Joanna
    Szaja, Aleksandra
    Szulzyk-Cieplak, Joanna
    Lagod, Grzegorz
    ENERGIES, 2020, 13 (22)
  • [29] Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant
    Xiaohong Zhou
    Yuanyuan Wu
    Hanchang Shi
    Yanqing Song
    Journal of Environmental Sciences, 2013, (02) : 295 - 301
  • [30] SUBMERGED AERATION SYSTEM FOR SECONDARY WASTEWATER-TREATMENT
    不详
    FOOD PRODUCTION/MANAGEMENT, 1977, 99 (10): : 14 - 15