Error detection thresholds for routine real time in vivo dosimetry in HDR prostate brachytherapy

被引:10
|
作者
Mason, Josh [1 ,2 ]
Henry, Ann [1 ,3 ]
Bownes, Peter [1 ]
机构
[1] Leeds Canc Ctr, Leeds, W Yorkshire, England
[2] Imperial Coll Healthcare NHS Trust, London, England
[3] Univ Leeds, Leeds, W Yorkshire, England
关键词
In vivo dosimetry; Prostate brachytherapy; DOSE-RATE BRACHYTHERAPY; VERIFICATION; CANCER;
D O I
10.1016/j.radonc.2020.04.058
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Routine real time in vivo dosimetry (IVD) is performed in HDR prostate brachytherapy to independently verify dose delivery. This study investigates impact of position uncertainty on error detection thresholds for IVD. Methods: IVD is implemented using a microMOSFET placed centrally in the prostate using an additional needle. 144 IVD measurements were made for 15 Gy or 19 Gy single fraction treatments. Needle insertion and treatment planning used real-time trans-rectal ultrasound. Source-MOSFET position thresholds of +/- 1, +/- 2 and +/- 3 mm were used to calculate per-needle and total plan error detection thresholds for the measured dose using an uncertainty analysis based on the treatment plan data. Results: The median dose difference from 144 total plan measurements was -5.2% (range +7.4% to - 17.3%). 3 plans measured outside the total plan error detection threshold for position threshold +/- 1 mm, no plans measured outside the total plan error detection threshold for larger position thresholds. For 2233 individual needle measurements, for position thresholds of +/- 1 mm, +/- 2mm and +/- 3 mm the number of needles outside the per-needle error detection threshold was 103, 25 and 10 respectively and the number of treatments that would have required interruption based on these thresholds for real-time IVD was 66, 16 and 8 respectively. Conclusion: IVD in HDR prostate brachytherapy using a microMOSFET provides a high level of confidence that we are correctly delivering the planned dose to our patients. A +/- 2-3 mm position threshold gives an appropriate balance between error detection and avoiding unnecessary treatment interruptions. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] Error detection thresholds for routine real time in vivo dosimetry in HDR prostate brachytherapy
    Mason, J.
    Henry, A.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S37 - S37
  • [2] Real-time in-vivo dosimetry in HDR prostate brachytherapy
    Mason, J.
    Al-Qaisieh, B.
    Henry, A.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S27 - S28
  • [3] Real-time in-vivo dosimetry for HDR prostate brachytherapy
    Mamo, A.
    Mason, J.
    Al-Qaisieh, B.
    Henry, A.
    Okkalides, D.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S85 - S86
  • [4] A scintillation dosimeter with real-time positional tracking information for in vivo dosimetry error detection in HDR brachytherapy
    Tho, Daline
    Lavallee, Marie-Claude
    Beaulieu, Luc
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (12):
  • [5] Adaptive error detection for HDR/PDR brachytherapy: Guidance for decision making during real-time in vivo point dosimetry
    Kertzscher, Gustavo
    Andersen, Claus E.
    Tanderup, Kari
    MEDICAL PHYSICS, 2014, 41 (05)
  • [6] Real-Time MOSkin In-Vivo Rectal Dosimetry for TRUS Based HDR Prostate Brachytherapy
    Poder, J.
    Howie, A.
    Brown, R.
    Bucci, J.
    Rosenfeld, A.
    Enari, K.
    Schreiber, K.
    Carrara, M.
    Malouf, D.
    Cutajar, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E842 - E843
  • [7] Real-time dosimetry for HDR brachytherapy
    Moutinho, L.
    Castro, I. F. C.
    Freitas, H.
    Silva, K. A.
    Rachinhas, P. J.
    Simoes, P. C. P. S.
    Veloso, J. F. C. A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S945 - S945
  • [8] Error Detection in HDR Prostate Brachytherapy with Plan-Specific Optimization of In-Vivo Dosimetry (IVD) Parameters
    Nunez, D. Aramburu
    Collier, M.
    Beaudry, J.
    Cohen, G.
    Damato, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [9] Real time in vivo dosimetry for cervix HDR brachytherapy - feasibility study using a MOSFET
    Mason, J.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S521 - S522
  • [10] Feasibility of real-time in vivo dosimetry for HDR gynaecological brachytherapy using a MOSFET.
    Mahmood, F.
    Mason, J.
    McLauchlan, R.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S494 - S495