An amplified graphene oxide-based fluorescence aptasensor based on target-triggered aptamer hairpin switch and strand-displacement polymerization recycling for bioassays

被引:45
|
作者
Hu, Kun [1 ]
Liu, Jinwen [1 ]
Chen, Jia [1 ]
Huang, Yong [1 ]
Zhao, Shulin [1 ]
Tian, Jianniao [1 ]
Zhang, Guohai [1 ]
机构
[1] Guangxi Normal Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Chem & Mol Engn Med Resources, Guilin 541004, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Aptamer; Graphene oxide; Strand-displacement polymerization; Amplified fluorescence assay; Interferon-gamma; HIGHLY SENSITIVE DETECTION; PROTEIN-DETECTION; NUCLEIC-ACID; RESONANCE; DNA; ASSAY; IONS; NANOPARTICLES; DNAZYME;
D O I
10.1016/j.bios.2012.11.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An amplified graphene oxide (GO) based fluorescence aptasensor based on target-triggered aptamer hairpin switch and strand-displacement polymerization recycling is developed for bioassays. The dye-labeled single-strand DNA (aptamer hairpin) was adsorbed on the surface of GO, which result in the fluorescence quenching of dye, and exhibiting minimal background fluorescence. Upon the target, primer and polymerase, the stem of the aptamer hairpin was opened, and binds with the primer to triggers the circular target strand-displacement polymerization reaction, which produces huge amounts of duplex helixes DNA and lead to strong fluorescence emission due to shielding of nucelobases within its double-helix structure. During the polymerization reaction, the primer was extended, and target was displaced. And the displaced target recognizes and hybridizes with another hairpin probe, triggering the next round of polymerization reaction, and the circle process induces fluorescence signal amplification for the detection of analyte. To test the feasibility of the aptasensor systems, interferon-gamma (IFN-gamma) was employed as a model analyte. A detection limit as low as 1.5 fM is obtained based on the GO aptasensor with a linear range of three orders of magnitude. The present method was successfully applied for the detection of IFN-gamma in human plasma. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:598 / 602
页数:5
相关论文
共 25 条
  • [21] Homogeneous Electrochemical Method for Ochratoxin A Determination Based on Target Triggered Aptamer Hairpin Switch and Exonuclease III-Assisted Recycling Amplification
    Chang Liu
    Yajing Guo
    Fang Luo
    Pingfan Rao
    Caili Fu
    Shaoyun Wang
    Food Analytical Methods, 2017, 10 : 1982 - 1990
  • [22] Fluorometric determination of agrA gene transcription in methicillin-resistant Staphylococcus aureus with a graphene oxide–based assay using strand-displacement polymerization recycling and hybridization chain reaction
    Yi Ning
    Shanquan Chen
    Jue Hu
    Ling Li
    Lijuan Cheng
    Fangguo Lu
    Microchimica Acta, 2020, 187
  • [23] Monitoring of lasR gene transcription in Pseudomonas aeruginosa via a graphene oxide-based fluorometric bioassay coupling strand displacement-triggered target recycling and exonuclease III-assisted signal amplification
    Tian, Longzhi
    Chen, Shanquan
    Ning, Yi
    MICROCHEMICAL JOURNAL, 2025, 208
  • [24] A two dimensional metal-organic framework nanosheets-based fluorescence resonance energy transfer aptasensor with circular strand-replacement DNA polymerization target-triggered amplification strategy for homogenous detection of antibiotics
    Yang, Qian
    Zhou, Lingying
    Wu, Yong-Xiang
    Zhang, Kai
    Cao, Yuting
    Zhou, You
    Wu, Dazhen
    Hu, Futao
    Gan, Ning
    ANALYTICA CHIMICA ACTA, 2018, 1020 : 1 - 8
  • [25] Nonenzymatic DNA-Based Fluorescence Biosensor Combining Carbon Dots and Graphene Oxide with Target-Induced DNA Strand Displacement for microRNA Detection
    Gao, Yuanyuan
    Yu, Hong
    Tian, Jingjing
    Xiao, Botao
    NANOMATERIALS, 2021, 11 (10)