Ultrasensitive measurement of gas refractive index using an optical nanofiber coupler

被引:68
|
作者
Li, Kaiwei [1 ]
Zhang, Nan [1 ,2 ]
Zhang, Nancy Meng Ying [1 ,2 ]
Liu, Guigen [3 ]
Zhang, Ting [1 ]
Wei, Lei [1 ,2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Nanyang Technol Univ, THALES, CNRS, CINTRA,UMI3288, Res Techno Plaza,50 Nanyang Dr, Singapore 637553, Singapore
[3] Univ Nebraska, Dept Elect & Comp Engn, Lincoln, NE 68588 USA
关键词
FABRY-PEROT-INTERFEROMETER; PHOTONIC CRYSTAL FIBER; AIR;
D O I
10.1364/OL.43.000679
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report an ultrasensitive gas refractive index (RI) sensor based on optical nanofiber couplers (ONCs). Theoretical analysis reveals that a dispersion turning point (DTP) exists when the diameter of the coupler is below 1000 nm. Leveraging this DTP, the gas RI sensitivity can be significantly improved to infinity. Then we experimentally demonstrate a DTP and achieve ultrahigh sensitivities of 46,470 nm/refractive index unit (RIU) and -45,550 nm/RIU around the DTP using an ONC with a diameter of 700 nm. More importantly, the unique twin dips/peaks interference characteristics around the DTP offers further enhancement on the sensitivity to 92,020 nm/RIU. The demonstrated sensor not only shows vast potential in ultrasensitive pressure sensing, acoustic sensing, gas sensing, and gas phase biomarker detection, but also provides a new tool for nonlinear optics, ultrafast optics, quantum optics, and ultracold atom optics. (C) 2018 Optical Society of America
引用
收藏
页码:679 / 682
页数:4
相关论文
共 50 条
  • [21] Simulations of refractive index variation in a multimode interference coupler: Application to gas sensing
    Mazingue, T.
    Kribich, R. K.
    Etienne, P.
    Moreau, Y.
    OPTICS COMMUNICATIONS, 2007, 278 (02) : 312 - 316
  • [22] Refractive-index measurement and inverse correction using optical coherence tomography
    Stritzel, Jenny
    Rahlves, Maik
    Roth, Bernhard
    OPTICS LETTERS, 2015, 40 (23) : 5558 - 5561
  • [23] Refractive index measurement of the mouse crystalline lens using optical coherence tomography
    Chakraborty, Ranjay
    Lacy, Kip D.
    Tan, Christopher C.
    Park, Han Na
    Pardue, Machelle T.
    EXPERIMENTAL EYE RESEARCH, 2014, 125 : 62 - 70
  • [24] Measurement of temperature coefficient of liquid refractive index using optical fiber interference
    Li, Zuowei
    Zhang, Wei
    Pei, Li
    Gao, Shuqin
    Wu, Xiaoli
    Jiguang Jishu/Laser Technology, 1993, 17 (01): : 50 - 52
  • [25] Measurement of Refractive Index Profile of Optical Fiber Using the Diffraction Phase Microscope
    Jafar-Fard, Mohammad R.
    Moon, Sucbei
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2012, 23 (04) : 135 - 142
  • [26] Measurement of the refractive index of an optical medium by using a white-light interferometer
    Nahm, KB
    Shin, ES
    Rhee, BK
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 1996, 29 (06) : 724 - 727
  • [27] Refractive index measurement of the isolated crystalline lens using optical coherence tomography
    Uhlhorn, Stephen R.
    Borja, David
    Manns, Fabrice
    Parel, Jean-Marie
    VISION RESEARCH, 2008, 48 (27) : 2732 - 2738
  • [28] Refractive index measurement of silicon thin films using slab optical waveguides
    Takezawa, N
    Kato, I
    Nojima, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (02): : 920 - 925
  • [29] Refractive index measurement using an optical cavity based biosensor with a differential detection
    Cho, SaiHim
    Brake, Joshua H.
    Joy, Cody
    Kim, Seunghyun
    OPTICAL DIAGNOSTICS AND SENSING XV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2015, 9332
  • [30] Refractive index measurement of silicon thin films using slab optical waveguides
    Waseda Univ, Tokyo, Japan
    Jpn J Appl Phys Part 1 Regul Pap Short Note Rev Pap, 2 (920-925):