Integrated quantitative susceptibility and R2* mapping for evaluation of liver fibrosis: An ex vivo feasibility study

被引:5
|
作者
Jafari, Ramin [1 ,2 ]
Hectors, Stefanie J. [1 ]
Koehne de Gonzalez, Anne K. [3 ]
Spincemaille, Pascal [1 ]
Prince, Martin R. [1 ]
Brittenham, Gary M. [4 ]
Wang, Yi [1 ,2 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[2] Cornell Univ, Meinig Sch Biomed Engn, Ithaca, NY 14853 USA
[3] Columbia Univ, Dept Pathol, Med Ctr, New York, NY 10032 USA
[4] Columbia Univ, Dept Pediat, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
liver fibrosis; magnetic resonance imaging; quantitative susceptibility mapping; ENABLED DIPOLE INVERSION; SAMPLING VARIABILITY; CHRONIC HEPATITIS; IRON; MRI; FAT; QUANTIFICATION; COLLAGEN; DISEASE; BIOPSY;
D O I
10.1002/nbm.4412
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To develop a method for noninvasive evaluation of liver fibrosis, we investigated the differential sensitivities of quantitative susceptibility mapping (QSM) and R-2* mapping using corrections for the effects of liver iron. Liver fibrosis is characterized by excessive accumulation of collagen and other extracellular matrix proteins. While collagen increases R-2* relaxation, measures of R-2* for fibrosis are confounded by liver iron, which may be present in the liver over a wide range of concentrations. The diamagnetic collagen contribution to susceptibility values measured by QSM is much less than the contribution of highly paramagnetic iron. In 19 ex vivo liver explants with and without fibrosis, QSM (chi), R-2* and proton density fat fraction (PDFF) maps were constructed from multiecho gradient-recalled echo (mGRE) sequence acquisition at 3 T. Median parameter values were recorded and differences between the MRI parameters in nonfibrotic vs. advanced fibrotic/cirrhotic samples were evaluated using Mann-Whitney U tests and receiver operating characteristic analyses. Logistic regression with stepwise feature selection was employed to evaluate the utility of combined MRI measurements for detection of fibrosis. Median R-2* increased in fibrotic vs. nonfibrotic liver samples (P= .041), while differences in chi and PDFF were nonsignificant (P= .545 andP= .395, respectively). Logistic regression identified the combination of chi and R-2* significant for fibrosis detection (logit [prediction] = -8.45 + 0.23 R-2* - 28.8 chi). For this classifier, a highly significant difference between nonfibrotic vs. advanced fibrotic/cirrhotic samples was observed (P= .002). The model exhibited an AUC of 0.909 (P= .003) for detection of advanced fibrosis/cirrhosis, which was substantially higher compared with AUCs of the individual parameters (AUC 0.591-0.784). An integrated QSM and R-2* analysis of mGRE 3 T imaging data is promising for noninvasive diagnostic assessment of liver fibrosis.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Accelerating quantitative susceptibility and R2*mapping using incoherent undersampling and deep neural network reconstruction
    Gao, Yang
    Cloos, Martijn
    Liu, Feng
    Crozier, Stuart
    Pike, G. Bruce
    Sun, Hongfu
    NEUROIMAGE, 2021, 240
  • [22] Reproducibility of R2* and quantitative susceptibility mapping (QSM) reconstruction methods in the basal ganglia of healthy subjects
    Santin, M. D.
    Didier, M.
    Valabregue, R.
    Cherif, L. Yahia
    Garcia-Lorenzo, D.
    de Sousa, P. Loureiro
    Bardinet, E.
    Lehericy, S.
    NMR IN BIOMEDICINE, 2017, 30 (04)
  • [23] Simultaneous R2* and quantitative susceptibility mapping measurement enables differentiation of thrombus hematocrit and age: an in vitro study at 3 T
    Christiansen, Spencer D.
    Liu, Junmin
    Boffa, Michael B.
    Drangova, Maria
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (11) : 1155 - +
  • [24] Assessment of MR-based R2* and quantitative susceptibility mapping for the quantification of liver iron concentration in a mouse model at 7T
    Simchick, Gregory
    Liu, Zhi
    Nagy, Tamas
    Xiong, May
    Zhao, Qun
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 2081 - 2093
  • [25] Improved Liver R2* Mapping by Averaging Decay Curves
    Xinyuan Zhang
    Jie Peng
    Changqing Wang
    Yanqiu Feng
    Qianjin Feng
    Xinzhong Li
    Wufan Chen
    Taigang He
    Scientific Reports, 7
  • [26] Improved Liver R2*Mapping by Averaging Decay Curves
    Zhang, Xinyuan
    Peng, Jie
    Wang, Changqing
    Feng, Yanqiu
    Feng, Qianjin
    Li, Xinzhong
    Chen, Wufan
    He, Taigang
    SCIENTIFIC REPORTS, 2017, 7
  • [27] R2*and R2 mapping for quantifying recruitment of superparamagnetic iron oxide-tagged endothelial progenitor cells to injured liver: tracking in vitro and in vivo
    Wang, Qingguo
    Li, Kangan
    Quan, Qimeng
    Zhang, Guixiang
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2014, 9 : 1815 - 1822
  • [28] R2 and R2*mapping for sensing cell-bound superparamagnetic nanoparticles: In vitro and murine in vivo testing
    Kuhlpeter, Rebecca
    Dahnke, Hannes
    Matuszewski, Lars
    Persigehl, Thorsten
    von Wallbrunn, Angelika
    Allkemper, Thomas
    Heindel, Walter L.
    Schaeffter, Tobias
    Bremer, Christoph
    RADIOLOGY, 2007, 245 (02) : 449 - 457
  • [29] Using IVIM-MRI and R2*Mapping to Differentiate Early Stage Liver Fibrosis in a Rat Model of Radiation-Induced Liver Fibrosis
    Liang, Jianye
    Song, Xiubao
    Xiao, Zeyu
    Chen, Hanwei
    Shi, Changzheng
    Luo, Liangping
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [30] Commissioning of Commercial Quantitative R2*Mapping Software for Clinical Use
    Taylor, B.
    Chen, H.
    Liu, H.
    Yung, J.
    Hou, P.
    Brock, K.
    Stafford, R. J.
    MEDICAL PHYSICS, 2021, 48 (06)