Estimation of Stroke Volume and Aortic Valve Area in Patients with Aortic Stenosis: A Comparison of Echocardiography versus Cardiovascular Magnetic Resonance

被引:31
|
作者
Guzzetti, Ezequiel [1 ]
Capoulade, Romain [2 ]
Tastet, Lionel [1 ]
Garcia, Julio [3 ,4 ,5 ]
Le Ven, Florent [6 ]
Arsenault, Marie [1 ]
Bedard, Elisabeth [1 ]
Larose, Eric [1 ]
Clavel, Marie-Annick [1 ]
Pibarot, Philippe [1 ]
机构
[1] Laval Univ, Inst Univ Cardiol & Pneumol Quebec, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[2] UNIV Nantes, Inst Thorax, CHU Nantes, CNRS,INSERM, Nantes, France
[3] Univ Calgary, Stephenson Cardiac Imaging Ctr, Dept Cardiac Sci & Radiol, Calgary, AB, Canada
[4] Univ Calgary, Stephenson Cardiac Imaging Ctr, Libin Cardiovasc Inst Alberta, Calgary, AB, Canada
[5] Alberta Childrens Prov Gen Hosp, Res Inst, Calgary, AB, Canada
[6] CHU Brest, Brest, France
基金
加拿大健康研究院;
关键词
Aortic stenosis; Stroke volume; Aortic valve area; Doppler echocardiography; Cardiovascular magnetic resonance; Left ventricular outflow tract; EFFECTIVE ORIFICE AREA; EUROPEAN ASSOCIATION; LOW-GRADIENT; AMERICAN SOCIETY; CARDIAC-OUTPUT; DOPPLER; IMPACT; FLOW; RECOMMENDATIONS; QUANTIFICATION;
D O I
10.1016/j.echo.2020.03.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In aortic stenosis, accurate measurement of left ventricular stroke volume (SV) is essential for the calculation of aortic valve area (AVA) and the assessment of flow status. Current American Society of Echocardiography and European Association of Cardiovascular Imaging guidelines suggest that measurements of left ventricular outflow tract diameter (LVOTd) at different levels (at the annulus vs 5 or 10 mm below) yield similar measures of SV and AVA. The aim of this study was to assess the effect of the location of LVOTd measurement on the accuracy of SV and AVA measured on transthoracic echocardiography (TTE) compared with cardiovascular magnetic resonance (CMR). Methods: One hundred six patients with aortic stenosis underwent both TTE and CMR. SV was estimated on TTE using the continuity equation with LVOTd measurements at four locations: at the annulus and 2, 5, and 10 mm below annulus. SV was also determined on CMR using phase contrast acquired in the aorta (SVCMR-PC), and a hybrid AVA(CMR-PC) was calculated by dividing SVCMR-PC by the transthoracic echocardiographic Doppler aortic velocity-time integral. Comparison between methods was made using Bland-Altman analysis. Results: Compared with the referentmethod of phase-contrast CMR for the estimation of SVCMR-PC and AVA(CMR-PC) (SVCMR-PC 83616 mL, AVA(CMR-PC) 1.2760.35cm(2)), the best agreement was obtained by measuring LVOTd at the annulus or 2 mm below (P = NS), whereas measuring 5 and 10 mm below the annulus resulted in significant underestimation ofSVandAVAbyup to 15.9617.3mLand 0.2460.28cm(2), respectively (P<.01 for all). Accuracy for classification of low flow was best at the annulus (86%) and 2 mm below (82%), whereas measuring 5 and 10 mm below the annulus significantly underperformed (69% and 61%, respectively, P <.001). Conclusions: Measuring LVOTd at the annulus or very close to it provides the most accurate measures of SV and AVA, whereas measuring LVOTd 5 or 10 mm below significantly underestimates these parameters and leads to significant overestimation of the severity of aortic stenosis and prevalence of low-flow status.
引用
收藏
页码:953 / +
页数:16
相关论文
共 50 条
  • [31] Absolute assessment of aortic valve stenosis by planimetry using cardiovascular magnetic resonance imaging: Comparison with transoesophageal echocardiography, transthoracic echocardiography, and cardiac catheterisation
    Reant, Patricia
    Lederlin, Mathieu
    Lafitte, Stephane
    Serri, Karim
    Montaudon, Michel
    Corneloup, Olivier
    Roudaut, Raymond
    Laurent, Francois
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (02) : 276 - 283
  • [32] Ascending Aortic Diameters in Congenital Aortic Stenosis: Cardiac Magnetic Resonance versus Transthoracic Echocardiography
    van der Linde, Denise
    Rossi, Alexia
    Yap, Sing C.
    McGhie, Jackie S.
    van den Bosch, Annemien E.
    Kirschbaum, Sharon W. M.
    Russo, Brunella
    van Dijk, Arie P. J.
    Moelker, Adriaan
    Krestin, Gabriel P.
    van Geuns, Robert-Jan M.
    Roos-Hesselink, Jolien W.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (05): : 497 - 504
  • [33] Ascending Aortic Dimensions: Comparison Between Cardiac Magnetic Resonance and Transthoracic Echocardiography in Congenital Aortic Stenosis Patients
    van der Linde, D.
    Rossi, A.
    Yap, S. C.
    McGhie, J. S.
    van den Bosch, A. E.
    Kirschbaum, S. W. M.
    van Dijk, A. P. J.
    Moelker, A.
    Krestin, G. P.
    van Geuns, R. -J. M.
    Roos-Hesselink, J. W.
    CARDIOLOGY, 2012, 121 (02) : 141 - 142
  • [34] Prognostic Value of Aortic Valve Area by Doppler Echocardiography in Patients With Severe Asymptomatic Aortic Stenosis
    Marechaux, Sylvestre
    Ringle, Anne
    Rusinaru, Dan
    Debry, Nicolas
    Bohbot, Yoan
    Tribouilloy, Christophe
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (05):
  • [35] Is cardiac magnetic resonance imaging as accurate as echocardiography in the assessment of aortic valve stenosis?
    Wong, Sophia
    Spina, Roberto
    Toemoe, Sianne
    Dhital, Kumud
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (04) : 480 - 486
  • [36] Impact of stroke volume on cardiovascular risk during progression of aortic valve stenosis
    Lonnebakken, Mai Tone
    De Simone, Giovanni
    Saeed, Sahrai
    Boman, Kurt
    Rossebo, Anne B.
    Bahlmann, Edda
    Gohlke-Baerwolf, Christa
    Gerdts, Eva
    HEART, 2017, 103 (18) : 1443 - 1448
  • [37] Comparison of Magnetic Resonance Imaging and Transthoracic Echocardiography in evaluating aortic valve morphology in patients with thoracic aortic aneurysm
    Wong, Charis Huey Ling
    Joshi, Nikhil
    Dweck, Marc
    Mackillop, Graham
    Newby, David
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2011, 16 : 109 - 109
  • [38] Quantification of Congenital Aortic Valve Stenosis in Pediatric Patients: Comparison Between Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography
    Sirin, Selma
    Nassenstein, Kai
    Neudorf, Ulrich
    Jensen, Christoph J.
    Mikat, Christian
    Schlosser, Thomas
    PEDIATRIC CARDIOLOGY, 2014, 35 (05) : 771 - 777
  • [39] Comparison of magnetic resonance imaging and transthoracic echocardiography in identifying aortic valve morphology in patients with thoracic aortic aneurysm
    Wong, Charis
    Joshi, Nikhil
    Dweck, Marc
    Mackillop, Graham
    Newby, David
    CIRCULATION, 2012, 125 (19) : E815 - E815
  • [40] Comparison of the effectiveness of transcatheter aortic valve implantation in patients with pure aortic valve regurgitation versus aortic stenosis
    Munoz-Garcia, E.
    Munoz-Garcia, M.
    Munoz Garcia, A. J. Antonio Jesus
    Pinilla-Garcia, J. M.
    Carrasco-Chinchilla, F.
    Dominguez-Franco, A. J.
    Alonso-Briales, J. H.
    Hernandez-Garcia, J. M.
    Jimenez-Navarro, M. F.
    De Teresa Galvan, E.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 600 - 601