Quantitation of glutathione and its oxidation products in erythrocytes by multiple-label stable-isotope dilution

被引:14
|
作者
Reinbold, Julia [1 ]
Koehler, Peter [1 ]
Rychlik, Michael [2 ,3 ]
机构
[1] German Res Ctr Food Chem, Leibniz Inst, D-85354 Freising Weihenstephan, Germany
[2] Tech Univ Munich, D-85350 Freising Weihenstephan, Germany
[3] Tech Univ Munich, ZIEL Res Ctr Nutr & Food Sci, D-85354 Freising Weihenstephan, Germany
关键词
Artifact monitoring; Erythrocytes; Glutathione; LC-MS/MS; Multiple isotope labeling; Stable isotope dilution assay; RED-BLOOD-CELLS; PERFORMANCE LIQUID-CHROMATOGRAPHY; OXIDIZED GLUTATHIONE; REDUCED GLUTATHIONE; QUANTIFICATION; DISULFIDE; HPLC;
D O I
10.1016/j.ab.2013.09.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multiple-label stable isotope dilution assay for quantifying glutathione (GSH), glutathione disulfide (GSSG), and glutathione sulfonic acid in erythrocytes was developed. As the internal standards, [C-13(3),N-15]glutathione, [C-13(4),N-15(2)]glutathione disulfide, and [C-13(3),N-15]glutathione sulfonic acid were used. Analytes and internal standards were detected by LC-MS/MS after derivatization of GSH with iodoacetic acid and dansylation of all compounds under study. The calibration functions for all analytes relative to their respective isotopologic standards revealed slopes close to 1.0 and negligible intercepts. As various labelings of the standards for GSH and GSSG were used, their simultaneous quantitation was possible, although GSH was partly oxidized to its disulfide during analysis. The degree of this artifact formation of GSSG was calculated from the abundance of the mixed disulfide formed from unlabeled GSH and its respective standard. Thus, the detected GSSG amount could be corrected for the artifact amount. In this way, the amount of GSSG in erythrocytes was found to be less than 0.5% of the GSH concentration. Similar to GSSG, the detected amount of glutathione sulfonic acid was found to be formed at least in part during the analytical process, but the degree could not be quantified. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 37 条
  • [1] Stable-isotope dilution analysis of galactose metabolites in human erythrocytes
    Schadewaldt, P
    Kamalanathan, L
    Hammen, HW
    Wendel, U
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (24) : 2833 - 2838
  • [2] QUANTITATION OF POTENT ODORANTS OF VIRGIN OLIVE OIL BY STABLE-ISOTOPE DILUTION ASSAYS
    GUTH, H
    GROSCH, W
    [J]. JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1993, 70 (05) : 513 - 518
  • [3] Mycotoxins in cereal products: Quantitation by stable isotope dilution assays
    Rychlik, M
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U69 - U69
  • [4] Quantitation of folates and their catabolites in blood plasma, erythrocytes, and urine by stable isotope dilution assays
    Moench, Sabine
    Netzel, Michael
    Netzel, Gabriele
    Rychlik, Michael
    [J]. ANALYTICAL BIOCHEMISTRY, 2010, 398 (02) : 150 - 160
  • [5] Simultaneous Quantitation of Cellular Cysteine, Homsteine, And Glutathione by Stable Isotope Dilution LC-MS
    Khartulyari, Stefanie
    Wei, Cong
    Whitehead, A. Steven
    Blair, Ian A.
    [J]. CHEMICAL RESEARCH IN TOXICOLOGY, 2008, 21 (12) : 2448 - 2448
  • [6] Development of a stable isotope dilution assay for the quantitation of glycidamide and its application to foods and model systems
    Granvogl, Michael
    Koehler, Peter
    Latzer, Larissa
    Schieberle, Peter
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (15) : 6087 - 6092
  • [7] Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices
    Jiří Kohoutek
    Tereza Procházková
    Ondřej Adamovský
    Miroslava Palíková
    Klára Hilscherová
    [J]. Analytical and Bioanalytical Chemistry, 2019, 411 : 5267 - 5275
  • [8] Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices
    Kohoutek, Jiri
    Prochazkova, Tereza
    Adamovsky, Ondrej
    Palikova, Miroslava
    Hilscherova, Klara
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (20) : 5267 - 5275
  • [9] Quantitative analysis quantitation of 2-n-nonyl-1,3-dioxolane by stable-isotope dilution gas chromatography mass spectrometry
    Zhong, WZ
    Sanders, PE
    Hauer, MJ
    Vrbanac, JJ
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 705 (01): : 39 - 45
  • [10] Quantitation of type B-trichothecene mycotoxins in foods and feeds by a multiple stable isotope dilution assay
    Stefan Asam
    Michael Rychlik
    [J]. European Food Research and Technology, 2007, 224 : 769 - 783