Experimental assessment of the Advanced Collapsed-cone Engine for scalp brachytherapy treatments

被引:6
|
作者
Cawston-Grant, Brie [1 ]
Morrison, Hali [1 ,2 ]
Sloboda, Ron S. [1 ,2 ]
Menon, Geetha [1 ,2 ]
机构
[1] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[2] Cross Canc Inst, Dept Med Phys, Edmonton, AB, Canada
关键词
ACE; Dosimetry calculations; Scalp; High-dose-rate (HDR); DOSE-RATE IR-192; TG-43; FORMALISM; FILM DOSIMETRY; BODY-TISSUES; MODEL; GEOMETRIES; PHANTOM;
D O I
10.1016/j.brachy.2017.10.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To experimentally assess the performance of the Advanced Collapsed-cone Engine (ACE) for Ir-192 high-dose-rate brachytherapy treatment planning of nonmelanoma skin cancers of the scalp. METHODS AND MATERIALS: A layered slab phantom was designed to model the head (skin, skull, and brain) and surface treatment mold using tissue equivalent materials. Six variations of the phantom were created by varying skin thickness, skull thickness, and size of air gap between the mold and skin. Treatment planning was initially performed using the Task Group 43 (TG-43) formalism with CT images of each phantom variation. Doses were recalculated using standard and high accuracy modes of ACE. The plans were delivered to Gafchromic EBT3 film placed between different layers of the phantom. RESULTS: Doses calculated by TG-43 and ACE and those measured by film agreed with each other at most locations within the phantoms. For a given phantom variation, average TG-43- and ACE-calculated doses were similar, with a maximum difference of (3 +/- 12)% (k = 2). Compared to the film measurements, TG-43 and ACE overestimated the film-measured dose by (13 +/- 12)% (k = 2) for one phantom variation below the skull layer. CONCLUSIONS: TG-43- and ACE-calculated and film-measured doses were found to agree above the skull layer of the phantom, which is where the tumor would be located in a clinical case. ACE appears to underestimate the attenuation through bone relative to that measured by film; however, the dose to bone is below tolerance levels for this treatment. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:489 / 499
页数:11
相关论文
共 16 条
  • [1] Investigations of the Advanced Collapsed-cone Engine for HDR Brachytherapy Scalp Treatments
    Cawston-Grant, Brie
    Morrison, Hali
    Sloboda, Ron
    Menon, Geetha
    [J]. MEDICAL PHYSICS, 2016, 43 (08) : 4936 - 4937
  • [2] Implementation and initial assessment of the advanced collapsed-cone engine for ocular brachytherapy dosimetry
    Morrison, Hali
    Menon, Geetha
    Larocque, Matthew P.
    Weis, Ezekiel
    Sloboda, Ron S.
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4400 - 4400
  • [3] Experimental verification of Advanced Collapsed-cone Engine for use with a multichannel vaginal cylinder applicator
    Cawston-Grant, Brie
    Morrison, Hali
    Menon, Geetha
    Sloboda, Ron S.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03): : 16 - 27
  • [4] An experimental verification of the Advanced Collapsed cone Engine for HDR skin brachytherapy
    Stansbridge, R.
    Caines, R.
    Lee, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1561 - S1562
  • [5] Commissioning of Advanced Collapsed Cone Engine Algorithm for Brachytherapy
    Swamidas, J.
    Parida, S.
    Joshi, K.
    Phurailatpam, R.
    Panda, S.
    Pradhan, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E447 - E447
  • [6] Evaluation of the Advanced Collapsed-cone Engine dose calculation algorithm for COMS eye plaques
    Morrison, H.
    Menon, G.
    Larocque, M.
    Weis, E.
    Sloboda, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S191 - S192
  • [7] A planning study evaluating the Advanced Collapsed cone Engine in HDR skin brachytherapy
    Stansbridge, R.
    Caines, R.
    Lee, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1569 - S1569
  • [8] Evaluation of the Advanced Collapsed Cone Engine (ACE) for Ir-192 brachytherapy treatment planning
    Eason, L.
    Mason, J.
    Bownes, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1239 - S1240
  • [9] Modeling of the direction modulated brachytherapy tandem applicator using the Oncentra Brachy advanced collapsed cone engine
    Safigholi, Habib
    van Veelen, Bob
    Niatsetski, Yury
    Song, William Y.
    [J]. BRACHYTHERAPY, 2018, 17 (06) : 1030 - 1036
  • [10] Evaluation of a collapsed-cone convolution algorithm for esophagus and surface mold 192Ir brachytherapy treatment planning
    Eason, Luke
    Mason, Josh
    Cooper, Rachel
    Radhakrishna, Ganesh
    Bownes, Peter
    [J]. BRACHYTHERAPY, 2021, 20 (02) : 393 - 400