Modeling of the direction modulated brachytherapy tandem applicator using the Oncentra Brachy advanced collapsed cone engine

被引:9
|
作者
Safigholi, Habib [1 ]
van Veelen, Bob [2 ]
Niatsetski, Yury [2 ]
Song, William Y. [3 ]
机构
[1] Islamic Azad Univ, Dept Elect Engn, Shiraz Branch, Shiraz 74731719870, Iran
[2] Elekta Brachytherapy, Veenendaal, Netherlands
[3] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA USA
关键词
Direction modulated brachytherapy; Oncentra Brachy; Advanced collapsed cone engine; Model-based dose calculation algorithms; Cervical cancer; GUIDED ADAPTIVE BRACHYTHERAPY; CERVICAL-CANCER; DOSE CALCULATION; IR-192; INTRACAVITARY; PROTOCOL; YB-169; ENERGY; CO-60; AAPM;
D O I
10.1016/j.brachy.2018.08.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: The direction modulated brachytherapy (DMBT) magnetic resonance-compatible tandem applicator, made from a tungsten alloy rod, has six symmetric peripheral grooves, designed specifically to enhance intensity modulation capacity through achieving directional radiation dose profiles. In this work, the directional dose distributions of the DMBT tandem were modeled and calculated with the Oncentra Brachy advanced collapsed cone engine (ACE), which was validated against Monte Carlo (MC) calculations. METHODS AND MATERIAL: The prototype 3D tandem applicator model was created for use in the Oncentra Brachy treatment planning system. The Ir-192 source was placed inside a DMBT tandem in one and six channels as a single dwell position (DP) per channel with the same index length, as well as 1 DP in a standard tandem. Dose distributions were calculated in a water medium by both ACE and MC and compared. RESULTS: For 1DP/6DP inside the DMBT and 1DP inside the standard tandem, respectively, the mean dose differences were 3.5/3.3% and <2.8% with the range of 0.1%-6.5%/0.2%-5% and 0.1%-5%, between ACE and MC, respectively. CONCLUSIONS: The DMBT tandem is successfully modeled in a commercial treatment planning system. The ACE algorithm is capable of accurately calculating highly directional dose distributions generated by a dense tungsten alloy contained within the DMBT tandem, with agreements achieved within <3.5%. (C) 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1030 / 1036
页数:7
相关论文
共 32 条
  • [1] Validation of a Commercial Oncentra Brachy TPS Using the Advanced Collapse Cone Engine (ACE) Algorithm for Direction Modulated Brachytherapy (DMBT) Tandem Applicator
    Safigholi, H.
    Niatsetski, Y.
    Song, W.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E400 - E401
  • [2] Validation of the Oncentra Brachy Advanced Collapsed cone Engine for a commercial 192Ir source using heterogeneous geometries
    Ma, Yunzhi
    Lacroix, Frederic
    Lavallee, Marie-Claude
    Beaulieu, Luc
    [J]. BRACHYTHERAPY, 2015, 14 (06) : 939 - 952
  • [3] Source Position Localization for ICBT Tandem & Ovoid Applicators Utilizing Oncentra Brachy Applicator Modeling
    Kemp, J.
    Price, M.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3777 - 3777
  • [4] Commissioning of Advanced Collapsed Cone Engine Algorithm for Brachytherapy
    Swamidas, J.
    Parida, S.
    Joshi, K.
    Phurailatpam, R.
    Panda, S.
    Pradhan, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E447 - E447
  • [5] A Benchmark Study On BrachyVision ACUROS TPS in Modeling a Direction Modulated Brachytherapy Tandem Applicator
    Meftahi, M.
    Song, W.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E825 - E826
  • [6] A Novel Multi -Channel Tandem Applicator for Direction Modulated Brachytherapy
    Meftahi, M.
    Song, W. Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E534 - E534
  • [7] An experimental verification of the Advanced Collapsed cone Engine for HDR skin brachytherapy
    Stansbridge, R.
    Caines, R.
    Lee, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1561 - S1562
  • [8] Quantitative CT assessment of a novel direction-modulated brachytherapy tandem applicator
    Elzibak, Alyaa H.
    Kager, Petronella M.
    Soliman, Abraam
    Paudel, Moti R.
    Safigholi, Habib
    Han, Dae Yup
    Karotki, Aliaksandr
    Ravi, Ananth
    Song, William Y.
    [J]. BRACHYTHERAPY, 2018, 17 (02) : 465 - 475
  • [9] A planning study evaluating the Advanced Collapsed cone Engine in HDR skin brachytherapy
    Stansbridge, R.
    Caines, R.
    Lee, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1569 - S1569
  • [10] Investigations of the Advanced Collapsed-cone Engine for HDR Brachytherapy Scalp Treatments
    Cawston-Grant, Brie
    Morrison, Hali
    Sloboda, Ron
    Menon, Geetha
    [J]. MEDICAL PHYSICS, 2016, 43 (08) : 4936 - 4937