Postoperative Intracochlear Electrocochleography in Pediatric Cochlear Implant Recipients: Association to Audiometric Thresholds and Auditory Performance

被引:14
|
作者
Attias, Joseph [1 ,2 ]
Ulanovski, David [3 ,4 ]
Hilly, Ohad [3 ,4 ]
Greenstein, Tally [2 ]
Sokolov, Merav [3 ,4 ]
HabibAllah, Suhail [1 ]
Mormer, Hen [1 ]
Raveh, Eyal [3 ,4 ]
机构
[1] Univ Haifa, Dept Commun Sci & Disorders, 199 Aba Khoushy Ave, IL-3498838 Haifa, Israel
[2] Schneider Childrens Med Ctr Israel, Inst Audiol & Clin Neurophysiol, Petah Tiqwa, Israel
[3] Schneider Childrens Med Ctr Israel, Dept Otorhinolaryngol, Petah Tiqwa, Israel
[4] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
来源
EAR AND HEARING | 2020年 / 41卷 / 05期
关键词
Auditory neuropathy; Children; Cochlear microphonics responses; Congenital; Electrocochleography; Residual hearing; ROUND WINDOW ELECTROCOCHLEOGRAPHY; ELECTRICAL-STIMULATION; HEARING-PRESERVATION; RESIDUAL HEARING; CHILDREN; NERVE; NEUROPATHY; SPEECH; PERCEPTION; DIAGNOSIS;
D O I
10.1097/AUD.0000000000000833
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: The aim of this study was to compare intracochlear-recorded cochlear microphonics (CM) responses to behavioral audiometry thresholds in young children, with congenital hearing loss, 2 to 5 years after cochlear implantation early in life. In addition, differences in speech and auditory outcomes were assessed among children with and without residual hearing. Design: The study was conducted at a tertiary, university-affiliated, pediatric medical center. CM responses by intracochlear electrocochleography technique were recorded from 102 implanted ears of 60 children and those responses correlated to behavioral audiometry thresholds at 0.125 to 2 kHz frequencies. All children had received Advanced Bionics cochlear implant with High Focus J1 or MidScala electrodes, along with extensive auditory rehabilitation before and after implantation, including the use of conventional hearing aids. Speech Spatial and Hearing Qualities, Category of Auditory Performance scale, and educational settings information were obtained for each participant. Those cochlear implantation (CI) outcomes were compared between children with or without residual CM responses. Results: Two distinctive CM responses patterns were found among the implanted children. Of all ears diagnosed with cochlear hearing loss (n = 88), only in 29 ears, clear CM responses were obtained. In all other ears, no CM responses were obtained at the maximum output levels. The CM responses were highly correlated with coefficients ranging from 0.7 to 0.83 for the audiometric behavioral thresholds at 0.125 to 2 kHz frequency range. Of all ears diagnosed with auditory neuropathy syndrome disorder (n = 14), eight ears had residual hearing and recordable CM postimplantation. The other six ears showed no recordable CM responses at maximum output levels for all tested frequencies. Those showed supposedly better CM responses than the behavioral audiometry threshold, however with poor correlations with tested frequency thresholds. Children with residual hearing showed significantly better auditory outcomes with CI, compared with those without residual hearing. Conclusions: In children with congenital cochlear hearing loss, the objective CM intracochlear responses can reliably predict the residual audiometric threshold. However, in children with auditory neuropathy syndrome disorder, the CM thresholds did not match the behavioral audiometric responses. Postoperatively, children with recordable CM responses, showing preserved residual hearing, demonstrated better CI outcomes.
引用
收藏
页码:1135 / 1143
页数:9
相关论文
共 50 条
  • [11] Clinical Applications of Intracochlear Electrocochleography in Cochlear Implant Users With Residual Acoustic Hearing
    Kim, Jeong-Seo
    JOURNAL OF AUDIOLOGY AND OTOLOGY, 2024, 28 (02): : 100 - 106
  • [12] Systematic Review of Auditory Training in Pediatric Cochlear Implant Recipients
    Rayes, Hanin
    Al-Malky, Ghada
    Vickers, Deborah
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2019, 62 (05): : 1574 - 1593
  • [13] Intraoperative Round Window Electrocochleography and Speech Perception Outcomes in Pediatric Cochlear Implant Recipients
    Formeister, Eric J.
    McClellan, Joseph H.
    Merwin, William H., III
    Iseli, Claire E.
    Calloway, Nathan H.
    Teagle, Holly F. B.
    Buchman, Craig A.
    Adunka, Oliver F.
    Fitzpatrick, Douglas C.
    EAR AND HEARING, 2015, 36 (02): : 249 - 260
  • [14] Intracochlear Electrocochleography: Influence of Scalar Position of the Cochlear Implant Electrode on Postinsertion Results
    Riggs, William J.
    Dwyer, Robert T.
    Holder, Jourdan T.
    Mattingly, Jameson K.
    Ortmann, Amanda
    Noble, Jack H.
    Dawant, Benoit M.
    Valenzuela, Carla V.
    O'Connell, Brendan P.
    Harris, Michael S.
    Litvak, Leonid M.
    Koka, Kanthaiah
    Buchman, Craig A.
    Labadie, Robert F.
    Adunka, Oliver F.
    OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : E503 - E510
  • [15] Real-Time Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant
    Harris, Michael S.
    Riggs, William Jason
    Koka, Kanthaiah
    Litvak, Leonid M.
    Malhotra, Prashant
    Moberly, Aaron C.
    O'Connell, Brendan P.
    Holder, Jourdan
    Alberto Di Lella, Federico
    Mario Boccio, Carlos
    Wanna, George B.
    Labadie, Robert F.
    Adunka, Oliver F.
    OTOLOGY & NEUROTOLOGY, 2017, 38 (06) : E107 - E113
  • [16] Systematic Review of Intracochlear Measurements and Effect on Postoperative Auditory Outcomes after Cochlear Implant Surgery
    Hasan, Zubair
    Key, Seraphina
    Lee, Michael
    Da Cruz, Melville
    OTOLOGY & NEUROTOLOGY, 2024, 45 (01) : E1 - E17
  • [17] The Relationship Between EABR and Auditory Performance and Speech Intelligibility Outcomes in Pediatric Cochlear Implant Recipients
    Wang, Yu
    Pan, Tao
    Deshpande, Shruti Balvalli
    Ma, Furong
    AMERICAN JOURNAL OF AUDIOLOGY, 2015, 24 (02) : 226 - 234
  • [18] Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea
    Haumann, Sabine
    Timm, Max E.
    Buechner, Andreas
    Lenarz, Thomas
    Salcher, Rolf B.
    TRENDS IN HEARING, 2024, 28
  • [19] Promontory Electrocochleography Recordings to Predict Speech-Perception Performance in Cochlear Implant Recipients
    Walia, Amit
    Shew, Matthew A.
    Lee, David S.
    Lefler, Shannon M.
    Kallogjeri, Dorina
    Wick, Cameron C.
    Durakovic, Nedim
    Fitzpatrick, Douglas C.
    Ortmann, Amanda J.
    Herzog, Jacques A.
    Buchman, Craig A.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (08) : 915 - 923
  • [20] Performance with an Auditory Brainstem Implant and Contralateral Cochlear Implant in Pediatric Patients
    Friedmann, David R.
    Asfour, Leena
    Shapiro, William H.
    Roland, J. Thomas, Jr.
    Waltzman, Susan B.
    AUDIOLOGY AND NEURO-OTOLOGY, 2018, 23 (04) : 216 - 221