Volar versus dorsal plating in the management of intra-articular distal radius fractures

被引:169
|
作者
Ruch, DS [1 ]
Papadonikolakis, A [1 ]
机构
[1] Duke Univ, Med Ctr, Div Orthopaed Surg, Durham, NC 27710 USA
来源
关键词
distal; dorsal; fractures; plating; radius; volar;
D O I
10.1016/j.jhsa.2005.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the complications and functional and radiographic outcomes of volar and dorsal plating of intra-articular distal radius fractures. Methods: This retrospective review included 34 patients found by searching a database of 350 patients treated for distal radius fractures. Inclusion criteria were (1) at least 1 year of follow-up data and (2) open reduction and internal fixation of a multifragmentary fragment intra-articular distal radius fracture with either a nonlocking volar or dorsal plate. Twenty patients were treated with a dorsal plate and 14 patients were treated with a volar nonlocking plate. Objective and subjective outcome parameters were compared between the 2 groups. Objective evaluations included wrist range of motion, grip strength, and preoperative and postoperative radiographic parameters (radial inclination, palmar tilt, ulnar variance, fracture pattern). Subjective evaluations were performed using the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score and the Gartland and Werley score. Results: Volar plating resulted in a significantly better Gartland-Werley score compared with dorsal plating. There were no significant differences in the DASH score.Volar collapse was documented in 5 of the 20 patients in the dorsal plating group, which resulted in a mild loss of pronation compared with the volar plating group. No collapse occurred in the volar plating group. In addition the difference in the percentage of wrist range of motion compared with the contralateral wrist was not significant. Dorsal plating was associated with a ruptured extensor indicis tendon in 1 patient; secondary surgical procedures were required in 4 patients (tenolyses and radial styloidectomy). Volar plating was associated with median nerve neuropathy in 2 patients and intersection syndrome in one. Conclusions: Although both groups of patients had similar DASH scores the functional outcome in terms of Gartland and Werley scores was better in the volar plating group. In addition there was a higher rate of volar collapse and late complications in the dorsal plating group compared with the volar plating group.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [31] Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures with Volar Lunate Facet Fragments Distal to the Watershed Line
    Nanno, Mitsuhiko
    Kodera, Norie
    Tomori, Yuji
    Takai, Shinro
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2020, 87 (01) : 24 - 31
  • [32] Combined Plating of Intra-Articular Distal Radius Fractures, a Consecutive Series of 74 Cases
    Sagerfors, Marcus
    Lundqvist, Eva
    Bjorling, Patrik
    JOURNAL OF WRIST SURGERY, 2020, 09 (05) : 388 - 395
  • [33] The Safety of the Volar Intraarticular Extended Window (VIEW) Approach for Intra-articular Distal Radius Fractures
    Kamal, Robin N.
    Gomez, Giselle I.
    Schultz, Emily A.
    Shapiro, Lauren M.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023,
  • [34] Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures
    Kumar, Sanjay
    Khan, A. N.
    Sonanis, S. V.
    JOURNAL OF ORTHOPAEDICS, 2016, 13 (04) : 376 - 382
  • [35] Rotational Fluoroscopy Assists in Detection of Intra-Articular Screw Penetration During Volar Plating of the Distal Radius
    Tweet, Matthew L.
    Calfee, Ryan P.
    Stern, Peter J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (04): : 619 - 627
  • [36] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178
  • [37] Retraction Note to: Single volar locking plating for the intra- and extra-articular distal radius fractures with dorsal metaphyseal comminution
    Xue-yang Gui
    Zhao-hui Cheng
    Hong-fei Shi
    Yi-xin Chen
    Jin Xiong
    Jun-fei Wang
    Xu-sheng Qiu
    Zi-tao Zhang
    Journal of Orthopaedic Surgery and Research, 17
  • [38] RETRACTED ARTICLE: Single volar locking plating for the intra- and extra-articular distal radius fractures with dorsal metaphyseal comminution
    Xue-yang Gui
    Zhao-hui Cheng
    Hong-fei Shi
    Yi-xin Chen
    Jin Xiong
    Jun-fei Wang
    Xu-sheng Qiu
    Zi-tao Zhang
    Journal of Orthopaedic Surgery and Research, 16
  • [39] Volar locking compression plating versus dorsal plating for fractures of the distal radius. A prospective, randomized study
    Zettl, R. P.
    Clauberg, E.
    Nast-Kolb, D.
    Ruchholtz, S.
    Kuehne, C. A.
    UNFALLCHIRURG, 2009, 112 (08): : 712 - +
  • [40] Anatomical reduction of intra-articular fractures of the distal radius
    Hems, TEJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03): : 460 - 460