High magnetic field test of bismuth Hall sensors for ITER steady state magnetic diagnostic

被引:23
|
作者
Duran, I. [1 ]
Entler, S. [1 ]
Kohout, M. [2 ]
Kocan, M. [3 ]
Vayakis, G. [3 ]
机构
[1] CAS, Inst Plasma Phys, Za Slovankou 3, Prague 18200 8, Czech Republic
[2] CAS, Inst Phys, Na Slovance 1992-2, Prague 18221 8, Czech Republic
[3] ITER Org, Route Vinon Sur Verdon, F-13076 St Paul Les Durance, France
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 11期
关键词
FUSION-REACTORS; PERFORMANCE;
D O I
10.1063/1.4964435
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Performance of bismuth Hall sensors developed for the ITER steady state magnetic diagnostic was investigated for high magnetic fields in the range +/- 7 T. Response of the sensors to the magnetic field was found to be nonlinear particularly within the range +/- 1 T. Significant contribution of the planar Hall effect to the sensors output voltage causing undesirable cross field sensitivity was identified. It was demonstrated that this effect can be minimized by the optimization of the sensor geometry and alignment with the magnetic field and by the application of "current-spinning technique." Published by AIP Publishing.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Test-bench for characterization of steady state magnetic sensors parameters in wide temperature range
    Kovarik, Karel
    Duran, Ivan
    Sentkerestiova, Jana
    Sestak, David
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 1319 - 1322
  • [22] Planar Hall Effect Magnetic Sensors with Extended Field Range
    Lahav, Daniel
    Schultz, Moty
    Amrusi, Shai
    Grosz, Asaf
    Klein, Lior
    SENSORS, 2024, 24 (13)
  • [23] Magnetic field detection limits for ultraclean graphene Hall sensors
    Brian T. Schaefer
    Lei Wang
    Alexander Jarjour
    Kenji Watanabe
    Takashi Taniguchi
    Paul L. McEuen
    Katja C. Nowack
    Nature Communications, 11
  • [24] Magnetic field detection limits for ultraclean graphene Hall sensors
    Schaefer, Brian T.
    Wang, Lei
    Jarjour, Alexander
    Watanabe, Kenji
    Taniguchi, Takashi
    McEuen, Paul L.
    Nowack, Katja C.
    NATURE COMMUNICATIONS, 2020, 11 (01)
  • [25] Novel Hall sensors developed for magnetic field imaging systems
    Cambel, Vladimir
    Karapetrov, Goran
    Novosad, Valentyn
    Bartolome, Elena
    Gregusova, Dagmar
    Fedor, Jan
    Kudela, Robert
    Soltys, Jan
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2007, 316 (02) : 232 - 235
  • [26] Design of the ITER high-frequency magnetic diagnostic coils
    Toussaint, M.
    Testa, D.
    Baluc, N.
    Chavan, R.
    Fournier, Y.
    Lister, J. B.
    Maeder, T.
    Marmillod, P.
    Sanchez, F.
    Stoeck, M.
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 1248 - 1251
  • [27] Assessment of the ITER high-frequency magnetic diagnostic set
    Testa, D.
    Carfantan, H.
    Toussaint, M.
    Chavan, R.
    Fournier, Y.
    Guterl, J.
    Lister, J. B.
    Maeder, T.
    Moret, J. -M.
    Perez, A.
    Sanchez, F.
    Schaller, B.
    Slater, C.
    Stoeck, M.
    Tonetti, G.
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 1149 - 1152
  • [28] Bilayer v=2 quantum Hall state in parallel high magnetic field
    Sawada, A
    Ezawa, ZF
    Ohno, H
    Horikoshi, Y
    Kumada, N
    Ohno, Y
    Kishimoto, S
    Matsukura, F
    Nagahama, S
    PHYSICA E, 2000, 6 (1-4): : 615 - 618
  • [29] Development and test of the static magnetic field test facility for the ITER Tokamak building
    Wang, Shusheng
    Gao, Ge
    Wang, Linsen
    Jiang, Qian
    FUSION ENGINEERING AND DESIGN, 2023, 191
  • [30] Magnetic coil design of steady magnetic field test facility for Tokamak complex
    Jiang, Li
    Lei, Hong
    Huang, Ya
    ENERGY REPORTS, 2021, 7 : 998 - 1008