RISK MITIGATION THROUGH THE APPLICATION OF NEW POWER UMBILICAL TECHNOLOGY

被引:0
|
作者
Dobson, Alan [1 ]
Frazer, Steven [1 ]
机构
[1] Technip, Newcastle Upon Tyne, Tyne & Wear, England
关键词
D O I
暂无
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
This paper describes the substantial service life improvements that can be achieved through a new, high technology solution developed for deep water electrical power umbilical and cable applications. The new design represents an enabling technology for power cable projects in the deepest and most dynamic waters, provides a lower risk solution for risers in highly stressed conditions and can give a technically improved solution for the range of electrical power umbilical application. The significant advantages of aluminum alloy cable bundles over traditional copper cable bundles under static and dynamic loading associated with a typical deep water floating installation are presented. A design case study is used to illustrate improvements in structural response and fatigue life associated with the aluminum alloy cable cores against conventional technologies. The paper concludes with an overview of the associated risk reduction through the implementation of the aluminum alloy cables in the form of a failure mode and effect analysis.
引用
收藏
页码:741 / 747
页数:7
相关论文
共 50 条
  • [41] Application of Wireless Power Transmission Technology
    Ma, Yuncong
    [J]. ADVANCES IN MATERIALS, MACHINERY, ELECTRONICS III, 2019, 2073
  • [42] Power application of superconductivity technology in China
    Han, Z
    Hu, XH
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2006, 19 (03): : S109 - S113
  • [43] Power-hammering through Glitch Amplification - Attacks and Mitigation
    Matas, Kaspar
    Tuan Minh La
    Khoa Dang Pham
    Koch, Dirk
    [J]. 28TH IEEE INTERNATIONAL SYMPOSIUM ON FIELD-PROGRAMMABLE CUSTOM COMPUTING MACHINES (FCCM), 2020, : 65 - 69
  • [44] Mitigation of power system collapse through active dyanamic buffers
    Weaver, WW
    Krein, PT
    [J]. PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 1080 - 1084
  • [45] Voltage Harmonics Mitigation through Hybrid Active Power Filer
    Sahito, Anwar Ali
    Tunio, Shah Murad
    Khizer, Arbab Nighat
    [J]. MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2016, 35 (01) : 101 - 110
  • [46] Decreasing the time-to-market through virtual risk assessment and risk mitigation
    Pecht, MG
    McCluskey, PF
    West, NW
    Azarm, S
    Pecht, J
    [J]. 1997 21ST INTERNATIONAL CONFERENCE ON MICROELECTRONICS - PROCEEDINGS, VOLS 1 AND 2, 1997, : 25 - 30
  • [47] Opportunities through new technology
    Schwan, R
    [J]. METALL, 1999, 53 (06): : 300 - 300
  • [48] Risk Mitigation Strategies for Emergency Power Upgrades in Critical Facilities
    Chow, Philip
    Walker, Matthew
    [J]. 2019 IEEE/IAS 55TH INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2019, : 181 - 186
  • [49] Security constrained optimal power shutoff for wildfire risk mitigation
    Rhodes, Noah
    Coffrin, Carleton
    Roald, Line
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2024,
  • [50] Emergency Power Upgrades in Critical Facilities: Strategies for Risk Mitigation
    Chow, Philip
    Walker, Matthew
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2020, 26 (04) : 14 - 21