The Contribution of a Frequency-Compression Hearing Aid to Contralateral Cochlear Implant Performance

被引:19
|
作者
Perreau, Ann E. [1 ,2 ]
Bentler, Ruth A. [2 ]
Tyler, Richard S. [2 ,3 ]
机构
[1] Augustana Coll, Dept Commun Sci & Disorders, Rock Isl, IL USA
[2] Univ Iowa, Dept Commun Sci & Disorders, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
关键词
Cochlear implant; frequency compression; frequency lowering; hearing aid; LINGUALLY DEAFENED ADULTS; SPEECH-PERCEPTION; BIMODAL HEARING; ACOUSTIC HEARING; OPPOSITE EARS; MELODY RECOGNITION; INTERAURAL LEVEL; LOCALIZATION; BENEFITS; STIMULATION;
D O I
10.3766/jaaa.24.2.4
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background: Frequency-lowering signal processing in hearing aids has re-emerged as an option to improve audibility of the high frequencies by expanding the input bandwidth. Few studies have investigated the usefulness of the scheme as an option for bimodal users (i.e., combined use of a cochlear implant and a contralateral hearing aid). In this study, that question was posed. Purpose: The purposes of this study were (1) to determine if frequency compression was a better bimodal option than conventional amplification and (2) to determine the impact of a frequency-compression hearing aid on speech recognition abilities. Research Design: There were two separate experiments in this study. The first experiment investigated the contribution of a frequency-compression hearing aid to contralateral cochlear implant (CI) performance for localization and speech perception in noise. The second experiment assessed monaural consonant and vowel perception in quiet using the frequency-compression and conventional hearing aid without the use of a contralateral Cl or hearing aid. Study Sample: Ten subjects fitted with a cochlear implant and hearing aid participated in the first experiment. Seventeen adult subjects with a cochlear implant and hearing aid or two hearing aids participated in the second experiment. To be included, subjects had to have a history of postlingual deafness, a moderate or moderate-to-severe hearing loss, and have not worn this type of frequency-lowering hearing aid previously. Data Collection and Analysis: In the first experiment, performance using the frequency-compression and conventional hearing aids was assessed on tests of sound localization, speech perception in a background of noise, and two self-report questionnaires. In the second experiment, consonant and vowel perception in quiet was assessed monaurally for the two conditions. In both experiments, subjects alternated daily between a frequency-compression and conventional hearing aid for 2 mo. The parameters of frequency compression were set individually for each subject, and audibility was measured for the frequency compression and conventional hearing aid programs by comparing estimations of the Speech Intelligibility Index (SII) using a modified algorithm (Bentler et al, 2011). In both experiments, the outcome measures were administered following the hearing aid fitting to assess performance at baseline and after 2 mo of use. Results: For this group of subjects, the results revealed no significant difference between the frequency-compression and conventional hearing aid on tests of localization and consonant recognition. Spondee-in-noise and vowel perception scores were significantly higher with the conventional hearing aid compared to the frequency-compression hearing aid after 2 mo of use. Conclusions: These results suggest that, for the subjects in this study, frequency compression is not a better bimodal option than conventional amplification. In addition, speech perception may be negatively influenced by frequency compression because formant frequencies are too severely compressed and can no longer be distinguished.
引用
收藏
页码:105 / 120
页数:16
相关论文
共 50 条
  • [31] Hearing aid optimization in the evaluation of cochlear implant candidacy
    Newall, P
    Oliver, J
    [J]. UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 281 - 283
  • [32] Sound Localization and Binaural Hearing in Children with a Hearing Aid and a Cochlear Implant
    Beijen, J.
    Snik, A. F. M.
    Straatman, L. V.
    Mylanus, E. A. M.
    Mens, L. H. M.
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2010, 15 (01) : 36 - 43
  • [33] Clinical Application of Spectral Modulation Detection: Speech Recognition Benefit for Combining a Cochlear Implant and Contralateral Hearing Aid
    Kessler, David M.
    Wolfe, Jace
    Blanchard, Michelle
    Gifford, Rene H.
    [J]. JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2020, 63 (05): : 1561 - 1571
  • [34] An Analysis of Hearing Aid Fittings in Adults Using Cochlear Implants and Contralateral Hearing Aids
    Harris, Michael S.
    Hay-McCutcheon, Marcia
    [J]. LARYNGOSCOPE, 2010, 120 (12): : 2484 - 2488
  • [35] Residual Hearing Affects Contralateral Routing of Signals in Cochlear Implant Users
    Stronks, H. Christiaan
    Briaire, Jeroen J.
    Frijns, Johan H. M.
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2022, 27 (01) : 75 - 82
  • [36] Cochlear Implant and Hearing Aid: Objective Measures of Binaural Benefit
    Balkenhol, Tobias
    Wallhaeusser-Franke, Elisabeth
    Rotter, Nicole
    Servais, Jerome J.
    [J]. FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [37] Sound separation with a cochlear implant and a hearing aid in opposite ears
    Department of Otolaryngology, University of Melbourne, Melbourne, Vic., Australia
    [J]. Acoustics Australia, 2001, 29 (01) : 9 - 12
  • [38] Quality of life after intervention with a cochlear implant or hearing aid
    Contrera, Kevin J.
    Betz, Joshua
    Li, Lingsheng
    Blake, Caitlin R.
    Sung, Yoon K.
    Choi, Janet S.
    Lin, Frank R.
    [J]. LARYNGOSCOPE, 2016, 126 (09): : 2110 - 2115
  • [39] The body image in hearing aid and cochlear implant users in Turkey
    Ozturk, Seda
    Ciprut, Ayca A.
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5199 - 5206
  • [40] The body image in hearing aid and cochlear implant users in Turkey
    Seda Ozturk
    Ayça A. Çiprut
    [J]. European Archives of Oto-Rhino-Laryngology, 2022, 279 : 5199 - 5206