Functional design of electrolytic biosensor

被引:1
|
作者
Preethichandra, D. M. Gamage [1 ]
Ekanayake, E. M. I. Mala [1 ]
Onoda, M. [2 ]
机构
[1] Cent Queensland Univ, Sch Engn & Technol, Rochhampton Campus,Bruce Hwy, Rockhampton, Qld 4702, Australia
[2] Univ Hyogo, Grad Sch Engn, 2167 Shosha, Himeji, Hyogo 6712280, Japan
关键词
GLUCOSE-OXIDASE;
D O I
10.1088/1742-6596/924/1/012010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel amperometric biosensbased on conjugated polypyrrole (PPy) deposited on a Pt modified ITO (indium tin oxide) conductive glass substrate and their performances are described. We have presented a method of developing a highly sensitive and low-cost nano-biosensor for blood glucose measurements. The fabrication method proposed decreases the cost of production significantly as the amount of noble metals used is minimized. A nano-corrugated PPy substrate was developed through pulsed electrochemical deposition. The sensitivity achieved was 325 mA/(Mcm(2))a nd the linear range of the developed sensor was 50-60 mmol/l. Then the application of the electrophoresis helps the glucose oxidase (GO(x)) on the PPy substrate. The main reason behind this high enzyme loading is the high electric field applied across the sensor surface (working electrode) and the counter electrode where that pushes the nano-scale enzyme particles floating in the phosphate buffer solution towards the substrate. The novel technique used has provided an extremely high sensitivities and very high linear ranges for enzyme (GO(x)) and therefore can be concluded that this is a very good technique to load enzyme onto the conducting polymer substrates.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Design of Nerve Signal Biosensor
    Soulier, Fabien
    Rossel, Olivier
    Bernard, Serge
    Cathebras, Guy
    Guiraud, David
    2009 JOINT IEEE NORTH-EAST WORKSHOP ON CIRCUITS AND SYSTEMS AND TAISA CONFERENCE, 2009, : 141 - 144
  • [22] Design of acetylcholinesterases for biosensor applications
    Schulze, H
    Vorlová, S
    Villatte, F
    Bachmann, TT
    Schmid, RD
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3): : 201 - 209
  • [23] A multi-functional plasmonic biosensor
    Chang, Yun-Tzu
    Lai, Yueh-Chun
    Li, Chung-Tien
    Chen, Cheng-Kuang
    Yen, Ta-Jen
    OPTICS EXPRESS, 2010, 18 (09): : 9561 - 9569
  • [24] INTERFACE ANALYSIS IN BIOSENSOR DESIGN
    GOPEL, W
    HEIDUSCHKA, P
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (9-10): : 853 - 883
  • [25] Computational biology - Biosensor design
    DeGrado, WF
    NATURE, 2003, 423 (6936) : 132 - 133
  • [26] Functional electrospun nanofibers for biosensor applications
    Gonzalez, Edurne
    Buttaro, Larissa
    Frey, Margaret
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [27] DEVELOPMENTS IN ELECTROLYTIC CAPACITOR DESIGN.
    Harrop, Peter J.
    Electronic Engineering (London), 1975, 47 (567): : 47 - 49
  • [28] ELECTROLYTIC TANK, DESIGN AND APPLICATIONS - COMMENTS
    FARR, HK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1957, 28 (04): : 296 - 297
  • [29] FACTORS IN THE DESIGN OF ELECTROLYTIC COPPER REFINERIES
    LEDEBOER, BJ
    JOURNAL OF METALS, 1982, 35 (12): : A13 - A13
  • [30] DESIGN AND MATERIALS OF CONSTRUCTION FOR ELECTROLYTIC CELLS
    MACMULLIN, RB
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1973, 120 (04) : C135 - C143