Chromatic X-ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

被引:106
|
作者
Bellazzini, R. [1 ,2 ]
Spandre, G. [1 ]
Brez, A. [1 ]
Minuti, M. [1 ]
Pinchera, M. [1 ]
Mozzo, P. [2 ]
机构
[1] INFN Pisa, I-56127 Pisa, Italy
[2] INFN Pisa, PIXIRAD Imaging Counters srl, I-56127 Pisa, Italy
来源
JOURNAL OF INSTRUMENTATION | 2013年 / 8卷
关键词
Solid state detectors; X-ray detectors; Pixelated detectors and associated VLSI electronics; X-ray radiography and digital radiography (DR); READOUT CHIP; DETECTOR; WORKING; MODE;
D O I
10.1088/1748-0221/8/02/C02028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An innovative X-ray imaging sensor based on Chromatic Photon Counting technology with intrinsic digital characteristics is presented. The system counts individually the incident X-ray photons and selects them according to their energy to produce two color images per exposure. The energy selection occurs in real time and at radiographic imaging speed (GHz global counting rate). Photon counting, color mode and a very fine spatial resolution (more than 10 LP/mm at MTF50) allow to obtain a high ratio between image quality and absorbed dose. The individual building block of the imaging system is a two-side buttable semiconductor radiation detector made of a thin pixellated CdTe crystal coupled to a large area VLSI CMOS pixel ASIC. Modules with 1, 2, 4, and 8 block units have been built. The largest module has 25 x 2.5 cm(2) sensitive area. Results and images obtained from testing different modules are presented.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Two-transistor active pixel sensor for high resolution large area digital X-ray imaging
    Taghibakhsh, Farhad
    Karim, Karim S.
    2007 IEEE INTERNATIONAL ELECTRON DEVICES MEETING, VOLS 1 AND 2, 2007, : 1011 - 1014
  • [42] Soft X-ray sensitivity of a photon-counting hybrid pixel detector with a silicon sensor matrix
    Fornaini, A
    Calvet, D
    Visschers, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01): : 142 - 145
  • [43] Active pixel sensor for X-ray imaging spectroscopy
    Lechner, P
    Hartmann, R
    Holl, P
    Johannes, T
    Klein, P
    Kollmer, J
    Lutz, G
    Richter, RH
    Strüder, L
    Fischer, P
    Trimpl, M
    Ulrici, J
    Wermes, N
    Castoldi, A
    Gatti, E
    Rehak, P
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 15 - 19
  • [44] Sphinx 1: Spectrometric Photon Counting and Integration Pixel for X-Ray Imaging with a 100 Electron LSB
    Habib, Amr
    Arques, Marc
    Dupont, Bertrand
    Rohr, Pierre
    Sicard, Gilles
    Tchagaspanian, Michael
    Verger, Loick
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [45] X-ray imaging with sub-micron resolution using large-area photon counting detectors Timepix
    Dudak, J.
    Karch, J.
    Holcova, K.
    Zemlicka, J.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [46] Development of a CdTe pixel detector with a window comparator ASIC for high energy X-ray applications
    Hirono, T.
    Toyokawa, H.
    Furukawa, Y.
    Honma, T.
    Ikeda, H.
    Kawase, M.
    Koganezawa, T.
    Ohata, T.
    Sato, M.
    Sato, G.
    Takagaki, M.
    Takahashi, T.
    Watanabe, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01): : 88 - 91
  • [47] Two-dimensional CdTe photon counting imager for hard X-ray
    Aoki, Toru
    Morii, Hisashi
    Ohashi, Gosuke
    Tomita, Yasuhiro
    Hatanaka, Yoshinori
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND PENETRATING RADIATION SYSTEMS VIII, 2006, 6319
  • [48] Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors
    Amendolia, S. R.
    Bisogni, M. G.
    Delogu, P.
    Fantacci, M. E.
    Paternoster, G.
    Rosso, V.
    Stefanini, A.
    MEDICAL PHYSICS, 2009, 36 (04) : 1330 - 1339
  • [49] X-ray detector with on-pixel amplification for large area diagnostic medical imaging
    Karim, KS
    Nathan, A
    Rowlands, JA
    Kasap, SO
    IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 2003, 150 (04): : 267 - 273
  • [50] Evaluation of Kyoto's event-driven X-ray astronomical SOI pixel sensor with a large imaging area
    Hayashi, Hideki
    Tsuru, Takeshi Go
    Tanaka, Takaaki
    Uchida, Hiroyuki
    Matsumura, Hideaki
    Tachibana, Katsuhiro
    Harada, Sodai
    Takeda, Ayaki
    Mori, Koji
    Nishioka, Yusuke
    Takebayashi, Nobuaki
    Yokoyama, Shoma
    Fukuda, Kohei
    Arai, Yasuo
    Kurachi, Ikuo
    Kawahito, Shoji
    Kagawa, Keiichiro
    Yasutomi, Keita
    Shrestha, Sumeet
    Nakanishi, Syunta
    Kamehama, Hiroki
    Kohmura, Takayoshi
    Hagino, Kouichi
    Negishi, Kousuke
    Oono, Kenji
    Yarita, Keigo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 400 - 403