Subsidence of the stem after impaction bone grafting for revision hip replacement using irradiated bone

被引:27
|
作者
Hassaballa, M. [1 ]
Mehendale, S. [1 ]
Poniatowski, S. [1 ]
Kalantzis, G. [1 ]
Smith, E. [1 ]
Learmonth, I. D. [1 ]
机构
[1] Univ Bristol, Bristol, Avon, England
来源
关键词
HUMAN-IMMUNODEFICIENCY-VIRUS; GAMMA-IRRADIATION; FEMORAL STEM; MECHANICAL-PROPERTIES; ALLOGRAFTS; TRANSPLANTATION; TRANSMISSION; CEMENT; EXETER; STERILIZATION;
D O I
10.1302/0301-620X.91B1.20376
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Loss of bone stock is a major problem in revision surgery of the hip. Impaction bone grafting of the femur is frequently used when dealing with deficient bone stock. In this retrospective study a consecutive series of 68 patients ( 69 hips) who had revision of a hip replacement with femoral impaction grafting were reviewed. Irradiated bone allograft was used in all hips. Radiological measurement of subsidence of the stem, incorporation of the graft and remodelling was carried out and showed incorporation of the graft in 26 of 69 hips ( 38%). However, there was no evidence of trabecular remodelling. Moderate subsidence of 5 mm to 10 mm occurred in ten hips ( 14.5%), and massive subsidence of > 10 mm in five ( 7.2%). The results of this study are less favourable than those of others describing studies of revision of the femoral stem using impaction bone grafting. The absence of the characteristic changes of graft remodelling noted in other series raises the question as to whether irradiated bone graft may be a significant factor influencing the post-operative outcome.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [21] Impaction grafting and acetabular reinforcement in revision hip replacement
    R. P. Pitto
    G. V. Di Muria
    D. Hohmann
    International Orthopaedics, 1998, 22 : 161 - 164
  • [22] Impaction grafting and acetabular reinforcement in revision hip replacement
    Pitto, RP
    Di Muria, GV
    Hohmann, D
    INTERNATIONAL ORTHOPAEDICS, 1998, 22 (03) : 161 - 164
  • [23] Femoral revision with impaction bone grafting and a cemented polished tapered stem
    Heyligers, I. C.
    Schreurs, B. W.
    van Haaren, E. H.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2014, 26 (02): : 156 - 161
  • [24] The use of hardened bone cement as an impaction grafting extender for revision hip arthroplasty
    Ruddy, Mark
    FitzPatrick, David P.
    Stanton, Kenneth T.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 78 : 82 - 90
  • [25] Stem micromotion after femoral impaction grafting using irradiated allograft bone: A time zero in vitro study
    Costi, John J.
    Edmonds-Wilson, Rohan H.
    Howie, Donald W.
    Stamenkov, Roumen
    Field, John R.
    Stanley, Richard M.
    Hearn, Trevor C.
    Callary, Stuart A.
    McGee, Margaret A.
    CLINICAL BIOMECHANICS, 2013, 28 (07) : 770 - 776
  • [26] Femoral impaction bone allografting with an Exeter cemented collarless, polished, tapered stem in revision hip replacement
    Wraighte, P. J.
    Howard, P. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08): : 1000 - 1004
  • [27] IMPACTION BONE GRAFTING FOR SEVERE FEMORAL BONE LOSS Surgical Technique in Revision Total Hip Arthroplasty
    Astore, Franco
    Molho, Nicolas M.
    Piccaluga, Francisco
    Comba, Fernando
    Slullitel, Pablo A.
    Buttaro, Martin A.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2022, 12 (01):
  • [28] Reconstruction of Acetabular and Femoral Bone Defects With Impaction Bone Grafting in Revision Hip Arthroplasty: A Case Report
    Golnik, Vadim N.
    Peleganchuk, Vladimir A.
    Batrak, Yuriy M.
    Pavlov, Vitaliy V.
    Kirilova, Irina A.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2023, 29 (03): : 102 - 109
  • [29] Revision total hip arthroplasty using impaction bone grafting with cemented nonpolished stems and charnley cups
    Boldt, JG
    Dilawari, P
    Agarwal, S
    Drabu, KJ
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 943 - 952
  • [30] A Preclinical Study of Stem Subsidence and Graft Incorporation After Femoral Impaction Grafting Using Porous Hydroxyapatite as a Bone Graft Extender
    Howie, Donald W.
    McGee, Margaret A.
    Callary, Stuart A.
    Carbone, Angelo
    Stamenkov, Roumen B.
    Bruce, Warrick J.
    Findlay, David M.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1050 - 1056