An evaluation of some pertinent parameters that influence the dosimetric performance of synthetic diamond detectors

被引:6
|
作者
Ade, N. [1 ,2 ]
Nam, T. L. [1 ,2 ]
Mhlanga, S. H. [3 ]
机构
[1] Univ Witwatersrand, Sch Phys, Radiat & Hlth Phys Unit, ZA-2050 Johannesburg, South Africa
[2] Univ Witwatersrand, DST NRF Ctr Excellence Strong Mat, ZA-2050 Johannesburg, South Africa
[3] Charlotte Maxeke Johannesburg Acad Hosp, Dept Radiat Sci, Div Med Phys, ZA-2000 Johannesburg, South Africa
基金
新加坡国家研究基金会;
关键词
Diamond; Pre-irradiation; Dose rate dependence; Relative dose; Angular dependence; HIGH-ENERGY ELECTRON; CHEMICAL-VAPOR-DEPOSITION; DOSE-RATE DEPENDENCE; CVD-DIAMOND; PHOTON BEAMS; RADIATION-THERAPY; RADIOTHERAPY; DEFECTS; PROBE; DISTRIBUTIONS;
D O I
10.1016/j.radphyschem.2013.01.038
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Although the near-tissue equivalence of diamond allows the direct measurement of dose for clinical applications without the need for energy-corrections, it is often cited that diamond detectors require pre-irradiation, a procedure necessary to stabilize the response or sensitivity of a diamond detector before dose measurements. In addition it has been pointed out that the relative dose measured with a diamond detector requires dose rate dependence correction and that the angular dependence of a detector could be due to its mechanical design or to the intrinsic angular sensitivity of the detection process. While the cause of instability of response has not been meticulously investigated, the issue of dose rate dependence correction is uncertain as some studies ignored it but reported good results. The aims of this study were therefore to investigate, in particular (1) the major cause of the unstable response of diamond detectors requiring pre-irradiation; (2) the influence of dose rate dependence correction in relative dose measurements; and (3) the angular dependence of the diamond detectors. The study was conducted with low-energy X-rays and electron therapy beams on HPHT and CVD synthesized diamonds. Ionization chambers were used for comparative measurements. Through systematic investigations, the major cause of the unstable response of diamond detectors requiring the recommended pre-irradiation step was isolated and attributed to the presence and effects of ambient light. The variation in detector's response between measurements in light and dark conditions could be as high as 63% for a CVD diamond. Dose rate dependence parameters (Delta values) of 0.950 and 1.035 were found for the HPHT and CVD diamond detectors, respectively. Without corrections based on dose rate dependence, the relative differences between depth-doses measured with the diamond detectors and a Markus chamber for exposures to 7 and 14 MeV electron beams were within 2.5%. A dose rate dependence correction using the Delta values obtained seemed to worsen the performance of the HPHT sample (up to about 3.3%) but it had a marginal effect on the performance of the CVD sample. In addition, the angular response of the CVD diamond detector was shown to be comparable with that of a cylindrical chamber. This study concludes that once the responses of the diamond detectors have been stabilised and they are properly shielded from ambient light, pre-irradiation prior to each measurement is not required. Also, the relative dose measured with the diamond detectors do not require dose rate dependence corrections as the required correction is only marginal and could have no dosimetric significance. (C) 2013 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:42 / 51
页数:10
相关论文
共 50 条
  • [31] INFLUENCE OF OREGANO EXTRACT ON THE INTESTINE, SOME PLASMA PARAMETERS AND GROWTH PERFORMANCE IN CHICKENS
    Levkut, M.
    Marcin, A.
    Revajova, Viera
    Lenhardt, L'
    Danielovic, I
    Hecl, J.
    Blanar, J.
    Levkutova, Maria
    Pistl, J.
    ACTA VETERINARIA-BEOGRAD, 2011, 61 (2-3): : 215 - 225
  • [32] AN EVALUATION OF PHYSIOLOGICAL-PARAMETERS AND THEIR INFLUENCE ON DOSES CALCULATED FROM 2 ALTERNATIVE DOSIMETRIC MODELS FOR THE GASTROINTESTINAL-TRACT
    LESSARD, ET
    SKRABLE, KW
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1983, 10 (01): : 53 - 54
  • [33] 3D-printed boluses for radiotherapy: influence of geometrical and printing parameters on dosimetric characterization and air gap evaluation
    Gugliandolo, Simone Giovanni
    Pillai, Shabarish Purushothaman
    Rajendran, Shankar
    Vincini, Maria Giulia
    Pepa, Matteo
    Pansini, Floriana
    Zaffaroni, Mattia
    Marvaso, Giulia
    Alterio, Daniela
    Vavassori, Andrea
    Durante, Stefano
    Volpe, Stefania
    Cattani, Federica
    Jereczek-Fossa, Barbara Alicja
    Moscatelli, Davide
    Colosimo, Bianca Maria
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 347 - 359
  • [34] On the influence of synthetic parameters on the properties and aldol condensation performance of the MgAl mixed oxides and rehydrated hydrotalcites
    Korolova, Valeriia
    Dubnova, Lada
    Vesely, Martin
    Lhotka, Miloslav
    Kikhtyanin, Oleg
    Kubicka, David
    APPLIED CLAY SCIENCE, 2024, 249
  • [35] A multimetric evaluation method for comprehensively assessing the influence of the icosahedral diamond grid quality on SCNN performance
    Duan, Yuanzheng
    Zhao, Xuesheng
    Sun, Wenbin
    Liu, Qingping
    Qin, Mengmeng
    INTERNATIONAL JOURNAL OF DIGITAL EARTH, 2024, 17 (01)
  • [36] INFLUENCE OF THE SURGICAL MASK ON THE PERCEPTION OF EFFORT AND SOME PHYSIOLOGICAL PARAMETERS IN THE PERFORMANCE OF AN INCREMENTAL TEST
    Tonguino-Rosero, S.
    Portuguez-Jaramillo, N.
    Pineros-Alvarez, J.
    Murillo, M.
    Rosero-Carvajal, H.
    CHEST, 2022, 161 (06) : 596A - 596A
  • [37] Evaluation of the biodegradation effectiveness of a persistent xenobiotic compound: Study of the influence of some process parameters
    Hemidouche, Sabra
    Favier, Lidia
    Amrane, Abdeltif
    Sadaoui, Zahra
    JOURNAL OF BIOTECHNOLOGY, 2017, 256 : S61 - S61
  • [38] EVALUATION OF THE INFLUENCE OF EXPERIMENTAL PARAMETERS ON THE PHOTOGALVANIC POTENTIAL OF SOME PHOTOSENSITIVE CHEMICAL-SYSTEMS
    SIMEONOV, V
    ALJANABI, K
    NOVKIRISHKA, M
    MARKOV, P
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (03): : 266 - 268
  • [39] EVALUATION OF SOME PARAMETERS OF RESPIRATORY FUNCTIONALITY IN 960 STUDENTS - INFLUENCE OF FAMILY AND AMBIENT FACTORS
    BERNARDI, F
    VILLA, MP
    MARANI, P
    POLLACCI, G
    TESTI, S
    REGGIANI, L
    TURA, A
    MESSINA, E
    CARLOZZO, BM
    MARTELLI, M
    SOLLAZZO, T
    CACCIARI, E
    RIVISTA ITALIANA DI PEDIATRIA-ITALIAN JOURNAL OF PEDIATRICS, 1985, 11 (05): : 575 - 575
  • [40] Evaluation of some parameters which influence the ESR measurements for the fading study of alanine dosimeters
    J. M. Dolo
    E. Pichot
    V. Feaugas
    Applied Magnetic Resonance, 1998, 15 : 269 - 277