In vitro stability of cemented and cementless femoral stems with compaction

被引:0
|
作者
Chareancholvanich, K
Bourgeault, CA
Schmidt, AH
Gustilo, RB
Lew, WD
机构
[1] Midwest Orthopaed Res Fdn, Orthopaed Biomech Lab, Minneapolis, MN 55404 USA
[2] Siriraj Hosp, Dept Orthopaed, Bangkok, Thailand
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Rigidity of initial fixation is a key factor contributing to the longevity of cemented and cementless femoral components in total hip arthroplasty. The objective of this study was to measure the initial stability of primary cemented and cementless femoral components under load when 15 pairs of cadaveric femurs were prepared by outward compaction of femoral cancellous bone in situ or by conventional extraction broaching. Three-dimensional micromotion was measured at proximal and distal locations on the femoral components using a device with spherical targets and linear variable differential transformers. External loads simulating the stance phases of level walking and stair ascent were applied to the femoral components by a materials test machine. Bone preparation method significantly affected each of the translation and rotation components of micromotion with cemented and cementless fixation. Micromotion with broaching was consistently greater than with compaction. Compared with compaction, the magnitude of the micromotion translation vector for broaching was an average of 3.9 (standard deviation, 3.1) times greater with cemented fixation, and an average of 2.3 (standard deviation, 1.4) times greater with cementless fixation. The results of this study showed the effectiveness of compaction of femoral cancellous bone in improving the initial stability of cemented and cementless femoral components in primary total hip arthroplasty.
引用
收藏
页码:290 / 302
页数:13
相关论文
共 50 条
  • [41] HEMIARTHROPLASTY FOR FEMORAL NECK FRACTURES IN THE ELDERLY: A Comparison of Cemented and Uncemented Femoral Stems
    DeRogatis, Michael J.
    Piatek, Allison Z.
    Jacob, Roshan
    Kelly, Sean C.
    Issack, Paul S.
    JBJS REVIEWS, 2020, 8 (07)
  • [42] Cemented and Press-fit Femoral Stems for the Management of Oncologic Femoral Tumors
    Su, Marie W.
    Groot, Oliver Q.
    Werenski, Joseph O.
    Sodhi, Alisha
    Merchan, Nelson
    Anderson, Megan E.
    Heincelman, Carrie
    Chang, Connie Y.
    Lozano-Calderon, Santiago A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2024, 32 (14) : e695 - e705
  • [43] Cemented versus cementless hemiarthroplasty for a displaced fracture of the femoral neck A SYSTEMATIC REVIEW AND META-ANALYSIS OF CURRENT GENERATION HIP STEMS
    Veldman, H. D.
    Heyligers, I. C.
    Grimm, B.
    Boymans, T. A. E. J.
    BONE & JOINT JOURNAL, 2017, 99B (04): : 421 - 431
  • [44] Cemented versus cementless revision femoral stems using morselized allograft - A prospektive, randomized study with 5 years follow-up
    Nesse, E
    Nielsen, EW
    Bastian, D
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2003, 141 (06): : 678 - 683
  • [45] On the biomechanical stability of cementless straight conical hip stems
    Viceconti, M.
    Pancanti, A.
    Varini, E.
    Traina, F.
    Cristofolini, L.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H3) : 473 - 480
  • [46] Clinical Performance of Ultra-Short Anatomic Cementless Versus Fourth-Generation Cemented Femoral Stems for Hip Replacement in Octogenarians
    Kim, Young-Hoo
    Park, Jang-Won
    Kim, Jun-Shik
    ORTHOPEDICS, 2018, 41 (04) : E470 - E478
  • [47] Influence of collars on the primary stability of cementless femoral stems: A finite element study using a diverse patient cohort
    Al-Dirini, Rami M. A.
    Huff, Daniel
    Zhang, Ju
    Besier, Thor
    Clement, John G.
    Taylor, Mark
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (04) : 1185 - 1195
  • [48] Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems
    B. C. H. van der Wal
    M. Vischjager
    B. Grimm
    I. C. Heyligers
    A. J. Tonino
    International Orthopaedics, 2005, 29 : 235 - 240
  • [49] Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems
    van der Wal, BCH
    Vischjager, M
    Grimm, B
    Heyligers, IC
    Tonino, AJ
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (04) : 235 - 240
  • [50] Outcomes of dual modular cementless femoral stems in revision hip arthroplasty
    Ghoz, Ali
    Broadhead, Matthew L.
    Morley, John
    Tavares, Shawn
    McDonald, David
    ORTHOPEDIC REVIEWS, 2014, 6 (01) : 43 - 47