Study on Arcless Switching Experiments of Hybrid On-Load Tap Changer in Transformers

被引:0
|
作者
Gao Fei
Zhang Shuqi
Yan Kuo
Li Jinzhong
Zheng Shirui
Ding Benping
机构
关键词
on-load tap changer; model prototype; thyristor modules; passive trigger; circuit of Extinction; switching experiment; EXPERIENCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The arc of traditional on-load tap changer in transformer during swithing period can significantly reduce contact's lifetime and accelerate the deterioration of transformer oil in switching process. In order to solve the above problems, this paper proposes a new principle of hybrid on-load tap changer, and the trial of the laboratory prototype model, using telescopic movement moving contacts to ensure switching sequence, mechanical components to achieve passive trigger of thyristor modules, assisting machinery with thyristor to achieve extinction in the process of switching. Establish a standard low-voltage switching test circuit, switching tests were under resistive load and inductive load conditions. Experimental results show that the process of switching thyristor in a trigger would be four times, twice during the current zero crossing off the natural, and twice turned off by bypass of mechanical switch. Experimental results validate shows the effectiveness of the hybrid arcless on-load tap switching method.
引用
收藏
页码:1287 / 1292
页数:6
相关论文
共 50 条
  • [21] Remote Monitoring of On-Load Tap Changer Switching Cycle Based on Acoustic Sensing
    Ralchev, Martin
    Mateev, Valentin
    Ivanov, Georgi
    Marinova, Iliana
    2021 13TH ELECTRICAL ENGINEERING FACULTY CONFERENCE (BULEF), 2021,
  • [22] Application vibroacoustic in the diagnosis of on-load tap changer
    Raclaw, Marcin
    Gielniak, Jaroslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (10): : 126 - 129
  • [23] Study on the condition of reverse control action of tap changer in a single on-load tap changer power system
    Yorino, Naoto, 1600, Scripta Technica Inc, New York, NY, United States (114):
  • [24] Vibration Characteristic Comparison Between Vacuum Arcing On-load Tap-changer and Oil Blast On-load Tap-changer
    Wang F.
    Fan J.
    Zheng Y.
    He W.
    Qian Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (09): : 2834 - 2841
  • [25] ON-LOAD TAP CHANGING FOR DISTRIBUTION TRANSFORMERS
    GROSU, S
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1972, 119 (04): : 467 - &
  • [26] Optimal sizing and placement of energy storage systems and on-load tap changer transformers in distribution networks
    Iria, Jose
    Heleno, Miguel
    Cardoso, Goncalo
    APPLIED ENERGY, 2019, 250 : 1147 - 1157
  • [27] A STUDY ON THE CONDITION OF REVERSE CONTROL ACTION OF TAP CHANGER IN A SINGLE ON-LOAD TAP CHANGER POWER-SYSTEM
    YORINO, N
    FUNAHASHI, A
    SASAKI, H
    KUBOKAWA, J
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (07) : 44 - 55
  • [28] Research on Oil Chamber Flow in On-load Tap-changer Switching Process with CFD
    Zhou, Haibin
    Liu, Guanwei
    Yan, Xiaojiang
    2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252
  • [29] On-load tap changer diagnosis with dynamic resistance measurements
    Jongen, Rogier
    Seitz, Paul P.
    Strehl, Thomas
    Smit, Johan
    Leich, Rory
    Gulski, Edward
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 485 - 488
  • [30] Protection Considerations for an Improperly Installed On-Load Tap Changer
    Rangel, Alex
    2021 74TH CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2021,