Wide 3-Dimensional Macular Ganglion Cell Complex Imaging with Spectral-Domain Optical Coherence Tomography in Glaucoma

被引:32
|
作者
Morooka, Satoshi [1 ]
Hangai, Masanori [1 ]
Nukada, Masayuki [1 ]
Nakano, Noriko [1 ]
Takayama, Kohei [1 ]
Kimura, Yugo [1 ]
Akagi, Tadamichi [1 ]
Ikeda, Hanako Ohashi [1 ]
Nonaka, Atsushi [1 ]
Yoshimura, Nagahisa [1 ]
机构
[1] Kyoto Univ, Dept Ophthalmol & Visual Sci, Grad Sch Med, Sakyo Ku, Kyoto 6068507, Japan
基金
日本学术振兴会;
关键词
NERVE-FIBER LAYER; HUMAN EYES; PREPERIMETRIC GLAUCOMA; THICKNESS; VOLUME; NEUROPATHY; DIAGNOSIS; RETINA; DAMAGE; OCT;
D O I
10.1167/iovs.12-9870
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine whether measurement of ganglion cell complex (GCC) thickness over a wide area (8-mm diameter) can improve the glaucoma-discriminating ability of spectral-domain optical coherence tomography (SD-OCT) compared to that in the standard macular area (6-mm diameter). METHODS. Ninety-three subjects were enrolled, including 46 healthy eyes of 46 volunteers and 47 eyes of 47 glaucoma patients (23 eyes with preperimetric glaucoma [PPG] and 24 eyes with early glaucoma [EG]). All patients underwent SD-OCT raster scanning over a 9 mmx9 mm square area centered on the fovea. Areas under the receiver operating characteristic curves (AROCs) were compared between wide sector (1-8-mm ring) and standard-size sector (1-6-mm ring) charts. RESULTS. AROCs for average GCC thickness in the wide chart were significantly greater than those of the standard chart in eyes with PPG (0.928 vs. 0.891; P = 0.038), EG (0.912 vs. 0.861; P = 0.003), and both (0.920 vs. 0.876; P = 0.004). Overall, the AROCs of regional GCC thicknesses were nearly comparable between the middle ring (4-6 mm) and outer ring (6-8 mm). Coefficients of variation were 0.68% and 0.97% in the standard and wide sector charts, respectively, in eyes with PPG, and 0.45% and 0.72% in the standard and wide sector charts, respectively, in eyes with EG. CONCLUSIONS. Addition of the GCC thickness outside the macula to the standard macular GCC thickness significantly increased the glaucoma-discriminating ability of SD-OCT. (Invest Ophthalmol Vis Sci. 2012;53:4805-4812) DOI: 10.1167/iovs.12-9870
引用
收藏
页码:4805 / 4812
页数:8
相关论文
共 50 条
  • [1] Macular Ganglion Cell Imaging Study: Glaucoma Diagnostic Accuracy of Spectral-Domain Optical Coherence Tomography
    Jeoung, Jin Wook
    Choi, Yun Jeong
    Park, Ki Ho
    Kim, Dong Myung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4422 - 4429
  • [2] Macular Ganglion Cell Imaging Study: Glaucoma Diagnostic Accuracy of Spectral-Domain Optical Coherence Tomography
    Jeoung, Jin Wook
    Choi, Yun Jeong
    Kim, Seok Hwan
    Park, Ki Ho
    Kim, Dong Myung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] Analysis of macular ganglion cell complex (GCC) with spectral-domain optical coherence tomography (SD-OCT) in glaucoma
    Renard, J. -P.
    Fenolland, J. -R.
    El Chehab, H.
    Francoz, M.
    Marill, A. -M.
    Messaoudi, R.
    Delbarre, M.
    Marechal, M.
    Michel, S.
    Giraud, J. -M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2013, 36 (04): : 299 - 309
  • [4] Macular Imaging for Glaucoma Using Spectral-domain Optical Coherence Tomography: A Review
    Wong, Jessica J.
    Chen, Teresa C.
    Shen, Lucy Q.
    Pasquale, Louis R.
    SEMINARS IN OPHTHALMOLOGY, 2012, 27 (5-6) : 160 - 166
  • [5] Effect of Axial Length on Macular Ganglion Cell Complex Thickness and on Early Glaucoma Diagnosis by Spectral-Domain Optical Coherence Tomography
    Nakanishi, Hideo
    Akagi, Tadamichi
    Hangai, Masanori
    Kimura, Yugo
    Suda, Kenji
    Hasegawa, Tomoko
    Yamada, Hiroshi
    Yoshikawa, Munemitsu
    Morooka, Satoshi
    Ikeda, Hanako Ohashi
    Yoshimura, Nagahisa
    JOURNAL OF GLAUCOMA, 2016, 25 (05) : E481 - E490
  • [6] Three-Dimensional Imaging of Macular Inner Structures in Glaucoma by Using Spectral-Domain Optical Coherence Tomography
    Kotera, Yuriko
    Hangai, Masanori
    Hirose, Fumitaka
    Mori, Satoshi
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1412 - 1421
  • [7] Macular Ganglion Cell Imaging Study: Covariate Effects on the Spectral Domain Optical Coherence Tomography for Glaucoma Diagnosis
    Jeong, Jae Hoon
    Choi, Yun Jeong
    Park, Ki Ho
    Kim, Dong Myung
    Jeoung, Jin Wook
    PLOS ONE, 2016, 11 (08):
  • [8] Clinical Validity of Macular Ganglion Cell Complex by Spectral Domain-Optical Coherence Tomography in Advanced Glaucoma
    Sung, Mi-Sun
    Kang, Byung-Wan
    Kim, Hwang-Gyun
    Heo, Hwan
    Park, Sang-Woo
    JOURNAL OF GLAUCOMA, 2014, 23 (06) : 341 - 346
  • [9] Prevalence and type of artefact with spectral domain optical coherence tomography macular ganglion cell imaging in glaucoma surveillance
    Awadalla, Mona S.
    Fitzgerald, Jude
    Andrew, Nicholas H.
    Zhou, Tiger
    Marshall, Henry
    Qassim, Ayub
    Hassell, Mark
    Casson, Robert J.
    Graham, Stuart L.
    Healey, Paul R.
    Agar, Ashish
    Galanopoulos, Anna
    Phipps, Simon
    Chappell, Angela
    Landers, John
    Craig, Jamie E.
    PLOS ONE, 2018, 13 (12):
  • [10] Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography
    Ng, Dorothy S. K.
    Gupta, Preeti
    Tham, Yih Chung
    Peck, Chye Fong
    Wong, Tien Yin
    Ikram, Mohammad Kamran
    Cheung, Carol Y.
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015