Three-Dimensional Imaging of Macular Inner Structures in Glaucoma by Using Spectral-Domain Optical Coherence Tomography

被引:83
|
作者
Kotera, Yuriko [1 ]
Hangai, Masanori [1 ]
Hirose, Fumitaka [1 ]
Mori, Satoshi [1 ]
Yoshimura, Nagahisa [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
基金
日本学术振兴会;
关键词
NERVE-FIBER LAYER; OPEN-ANGLE GLAUCOMA; THICKNESS MEASUREMENTS; FIELD LOSS; HUMAN EYES; ONSET; DISK; JAPANESE; VOLUME; OCT;
D O I
10.1167/iovs.10-5572
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To profile macular thickness changes in glaucoma by using three-dimensional spectral-domain optical coherence tomography (3D-SD-OCT). METHODS. The study included 30 eyes with suspected glaucoma and preperimetric glaucoma (SGPPG) and 35 healthy eyes. The macular thickness, including those of the total retina, nerve fiber layer (NFL), and combined inner retinal layers (IRLs)-NFL+ganglion cell layer (GCL)+inner plexiform layer (IPL)-was measured by 3D-SD-OCT raster scans in a 6 mm(2) region. The average and sectoral thicknesses were calculated on an Early Treatment of Diabetic Retinopathy Study (ETDRS) chart and a ETDRS chart with a 450 rotation (glaucoma sector chart, GSC). RESULTS. The mean IRL thickness was significantly less in the SGPPG eyes than in the healthy eyes, but the mean total retinal and macular NFL thicknesses were not. In the SGPPG eyes, the IRLs were thinner in the outer macula than in the inner macula, in the inferior hemisphere than in the superior hemisphere, and in the temporal hemisphere than in the nasal hemisphere. The significantly thinned sectors were nearly identical on the GSC but only slightly overlapped on the ETDRS chart. The Has in the inferior temporal outer sector (GSC) had the greatest area under the receiver operating characteristic curve, which was significantly greater than those for the IRLs over the entire macula, inferior hemiretinal region, and inferior outer hemicircular region (macular subfields), and that for the circumpapillary NFL in the inferior sectors (P = 0.001-0.036). CONCLUSIONS. Macular IRL thickness measured by using 3D-SD-OCT is useful for profiling macular atrophy in SGPPG. (Invest Ophthalmol Vis Sci 2011;52:1412-1421) DOI:10.1167/iovs.10-5572
引用
收藏
页码:1412 / 1421
页数:10
相关论文
共 50 条
  • [1] Three-Dimensional Imaging of the Macular Retinal Nerve Fiber Layer in Glaucoma with Spectral-Domain Optical Coherence Tomography
    Sakamoto, Atsushi
    Hangai, Masanori
    Nukada, Masayuki
    Nakanishi, Hideo
    Mori, Satoshi
    Kotera, Yuriko
    Inoue, Ryo
    Yoshimura, Nagahisa
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (10) : 5062 - 5070
  • [2] Macular Imaging for Glaucoma Using Spectral-domain Optical Coherence Tomography: A Review
    Wong, Jessica J.
    Chen, Teresa C.
    Shen, Lucy Q.
    Pasquale, Louis R.
    [J]. SEMINARS IN OPHTHALMOLOGY, 2012, 27 (5-6) : 160 - 166
  • [3] Three-Dimensional Evaluation of the Lamina Cribrosa Using Spectral-Domain Optical Coherence Tomography in Glaucoma
    Lee, Eun Ji
    Kim, Tae-Woo
    Weinreb, Robert N.
    Suh, Min Hee
    Kang, Myungjoo
    Park, Ki Ho
    Kim, Seok Hwan
    Kim, Dong Myung
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) : 198 - 204
  • [4] Three-Dimensional Spectral-Domain Optical Coherence Tomography Data Analysis for Glaucoma Detection
    Xu, Juan
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Bilonick, Richard A.
    Folio, Lindsey S.
    Nadler, Zach
    Kagemann, Larry
    Schuman, Joel S.
    [J]. PLOS ONE, 2013, 8 (02):
  • [5] Intraoperative Use of Three-Dimensional Spectral-Domain Optical Coherence Tomography
    Ide, Takeshi
    Wang, Jianhua
    Tao, Aizhu
    Leng, Theodore
    Kymionis, George D.
    O'Brien, Terrence P.
    Yoo, Sania H.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (02) : 250 - 254
  • [6] Analyzing the impact of glaucoma on the macular architecture using spectral-domain optical coherence tomography
    Unterlauft, Jan D.
    Rehak, Matus
    Boehm, Michael R. R.
    Rauscher, Franziska G.
    [J]. PLOS ONE, 2018, 13 (12):
  • [7] Automated Assessment of Drusen Using Three-Dimensional Spectral-Domain Optical Coherence Tomography
    Iwama, Daisuke
    Hangai, Masanori
    Ooto, Sotaro
    Sakamoto, Atsushi
    Nakanishi, Hideo
    Fujimura, Takashi
    Domalpally, Amitha
    Danis, Ronald P.
    Yoshimura, Nagahisa
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (03) : 1576 - 1583
  • [8] Imaging patients with glaucoma using spectral-domain optical coherence tomography and optical microangiography
    Auyeung, Kris
    Auyeung, Kelsey
    Kono, Rei
    Chen, Chieh-Li
    Zhang, Qinqin
    Wang, Ruikang K.
    [J]. DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS XII, 2015, 9322
  • [9] Detecting glaucoma progression using optic nerve volume scans with three-dimensional spectral-domain optical coherence tomography
    Ratanawongphaibul, Kitiya
    Chen, Teresa C.
    Tsikata, Edem
    Zemplenyi, Michele
    Lee, Hang
    Margeta, Milica
    Ondeck, Courtney
    Kim, Janice
    Pan, Billy
    Petrakos, Paul
    Coleman, Anne L.
    Yu, Fei
    de Boer, Johannes
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [10] Spectral-domain Optical Coherence Tomography Measurement of Macular Volume for Diagnosing Glaucoma
    Mori, Satoshi
    Hangai, Masanori
    Sakamoto, Atsushi
    Yoshimura, Nagahisa
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (08) : 528 - 534