3D Intra-cardiac flow estimation using speckle tracking: a feasibility study in synthetic ultrasound data

被引:8
|
作者
Gao, Hang [1 ]
Heyde, Brecht [1 ]
D'hooge, Jan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Lab Cardiovasc Imaging & Dynam, Leuven, Belgium
关键词
PARTICLE IMAGE VELOCIMETRY;
D O I
10.1109/ULTSYM.2013.0018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In recent years, echo particle image velocimetry (EPIV) has been proposed to characterize intra-cardiac flow fields noninvasively. To date, these methods remain two dimensional (2D). As volumetric cardiac ultrasound has become more readily available and as this may avoid some of the problems inherent to 2D imaging (i.e. out-of-plane flow), the aim of this study was to test whether EPIV could be extended to three dimensions using synthetic data sets. A typical inflow velocity profile and a dynamic LV volume change profile combined with a three-dimensional (3D) anatomical model of the LV were used to build a realistic computational fluid dynamics (CFD) flow vector field (Fluent 12.1, ANSYS). 3D B-mode image sequences were acquired using a fast ultrasound simulator (COLE) of virtual contrast bubbles moving along this 3D flow field (frequency = 4.5MHz; sampling frequency = 50MHz; 50x50 degrees opening angle; frame rate = 113 Hz; image size 120x60x60mm). Inter-frame motion during diastasis was estimated by volumetric speckle tracking (kernel 0.65x6.70x6.70mm; search region 4.96x9.71x8.85mm; overlap 40%x90%x90%) using 3D normalized cross-correlation as a similarity metric. Cubic spline interpolation was embedded for subsample motion estimation prior to median filtering (6.34x4.73x4.75mm) of the resulting velocity vector field. Regression and correlation coefficients as well as the estimate error of the tracking velocity field with the CFD reference ground truth were calculated. The relative point-wise velocity vector error averaged over the period of E wave, A wave and systole were 14.66 +/- 2.66%, 12.61 +/- 1.15%, 14.00 +/- 7.60% respectively. The flow field obtained through speckle tracking agreed well with the ones measured from CFD when the velocity amplitude was below 0.35 m/s. However, for larger velocities, the regional motion was underestimated.
引用
收藏
页码:68 / 71
页数:4
相关论文
共 50 条
  • [21] Atrial septal defect tracking in 3D cardiac ultrasound
    Linguraru, Marius George
    Vasilyev, Nikolay V.
    del Nido, Pedro J.
    Howe, Robert D.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 596 - 603
  • [22] Model-based estimation of intra-cardiac blood flow velocities using an unscented Kalman filter
    Hogenes, Jakob
    Wigen, Morten
    Nyrnes, Siri Ann
    Segers, Patrick
    Swillens, Abigail
    Lovstakken, Lasse
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [23] 3D Tendon Strain Estimation Using High-frequency Volumetric Ultrasound Images: A Feasibility Study
    Carvalho, Catarina
    Slagmolen, Pieter
    Bogaerts, Stijn
    Scheys, Lennart
    D'hooge, Jan
    Peers, Koen
    Maes, Frederik
    Suetens, Paul
    ULTRASONIC IMAGING, 2018, 40 (02) : 67 - 83
  • [24] The role of 3D and speckle tracking echocardiography in cardiac amyloidosis: a case report
    Nucci, E. M.
    Lisi, M.
    Cameli, M.
    Baldi, L.
    Puccetti, L.
    Mondillo, S.
    Favilli, R.
    Lunghetti, S.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2014, 18 (01) : 74 - 77
  • [25] Mitral valve analysis using a novel 3D holographic display: a feasibility study of 3D ultrasound data converted to a holographic screen
    Jan Otto Beitnes
    Lars Gunnar Klæboe
    Jørn Skaarud Karlsen
    Stig Urheim
    The International Journal of Cardiovascular Imaging, 2015, 31 : 323 - 328
  • [26] Mitral valve analysis using a novel 3D holographic display: a feasibility study of 3D ultrasound data converted to a holographic screen
    Beitnes, Jan Otto
    Klaeboe, Lars Gunnar
    Karlsen, Jorn Skaarud
    Urheim, Stig
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (02): : 323 - 328
  • [27] Guidance of cardiac pacemaker leads using real time 3D ultrasound: Feasibility studies
    Smith, SW
    Booi, RC
    Light, ED
    Merdes, CL
    Wolf, PD
    ULTRASONIC IMAGING, 2002, 24 (02) : 119 - 128
  • [28] Real-Time Noninvasive Intra-Cardiac Pressure Estimation Using Subharmonic Signals From Ultrasound Contrast Agents
    Esposito, Cara
    Machado, Priscilla
    McDonald, Maureen
    Mehrotra, Praveen
    Savage, Michael P.
    Fischman, David L.
    Cohen, Ira
    Ruggiero, Nicholas J.
    Walinsky, Paul
    Vishnevsky, Oleg
    Boyle, Andrew
    Davis, Marguerite
    Forsberg, Flemming
    Dickie, Kristopher
    Dave, Jaydev K.
    CIRCULATION, 2019, 140
  • [29] Optimization of 3D ultrasound scan spacing using speckle statistics
    Smith, WL
    Fenster, A
    MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 : 56 - 67
  • [30] Feasibility study of 3D cardiac imaging using a portable conebeam scanner
    Petrov, Ivailo
    Helm, Patrick A.
    Drangova, Maria
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313