3D Intra-cardiac flow estimation using speckle tracking: a feasibility study in synthetic ultrasound data

被引:8
|
作者
Gao, Hang [1 ]
Heyde, Brecht [1 ]
D'hooge, Jan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Lab Cardiovasc Imaging & Dynam, Leuven, Belgium
关键词
PARTICLE IMAGE VELOCIMETRY;
D O I
10.1109/ULTSYM.2013.0018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In recent years, echo particle image velocimetry (EPIV) has been proposed to characterize intra-cardiac flow fields noninvasively. To date, these methods remain two dimensional (2D). As volumetric cardiac ultrasound has become more readily available and as this may avoid some of the problems inherent to 2D imaging (i.e. out-of-plane flow), the aim of this study was to test whether EPIV could be extended to three dimensions using synthetic data sets. A typical inflow velocity profile and a dynamic LV volume change profile combined with a three-dimensional (3D) anatomical model of the LV were used to build a realistic computational fluid dynamics (CFD) flow vector field (Fluent 12.1, ANSYS). 3D B-mode image sequences were acquired using a fast ultrasound simulator (COLE) of virtual contrast bubbles moving along this 3D flow field (frequency = 4.5MHz; sampling frequency = 50MHz; 50x50 degrees opening angle; frame rate = 113 Hz; image size 120x60x60mm). Inter-frame motion during diastasis was estimated by volumetric speckle tracking (kernel 0.65x6.70x6.70mm; search region 4.96x9.71x8.85mm; overlap 40%x90%x90%) using 3D normalized cross-correlation as a similarity metric. Cubic spline interpolation was embedded for subsample motion estimation prior to median filtering (6.34x4.73x4.75mm) of the resulting velocity vector field. Regression and correlation coefficients as well as the estimate error of the tracking velocity field with the CFD reference ground truth were calculated. The relative point-wise velocity vector error averaged over the period of E wave, A wave and systole were 14.66 +/- 2.66%, 12.61 +/- 1.15%, 14.00 +/- 7.60% respectively. The flow field obtained through speckle tracking agreed well with the ones measured from CFD when the velocity amplitude was below 0.35 m/s. However, for larger velocities, the regional motion was underestimated.
引用
收藏
页码:68 / 71
页数:4
相关论文
共 50 条
  • [1] Image Thickness Correction for Navigation with 3D Intra-cardiac Ultrasound Catheter
    Zhong, Hua
    Kanade, Takeo
    Schwartzman, David
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 485 - 492
  • [2] Fusion of 3D Ultrasound and Cardiac-MRI Shows Motional Intra-Cardiac Blood Flow In the Whole Cardiac Cycle
    Sughimoto, Koichi
    Shimamura, Yoshiaki
    Liu, Hao
    Tsubota, Ken'ichi
    Miyaji, Kagami
    Yoshii, Takeshi
    Torii, Shinzo
    Kitamura, Tadashi
    Hirata, Mitsuhiro
    Mishima, Toshiaki
    Horai, Tetsuya
    Haneishi, Hideaki
    CARDIOLOGY, 2016, 134 (02) : 224 - 225
  • [3] 3D Characterization of corneal deformation using ultrasound speckle tracking
    Clayson, Keyton
    Pavlatos, Elias
    Ma, Yanhui
    Liu, Jun
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (06)
  • [4] STRAIN ANALYSIS OF CARDIAC TISSUES FROM 3D ULTRASOUND IMAGES USING SNAKES AND SPECKLE TRACKING
    Lanconelli, Nico
    Masetti, Simone
    Nardinocchi, Paola
    Teresi, Luciano
    Puddu, Paolo Emilio
    Torromeo, Concetta
    Giglio, Vincenzo
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (02)
  • [5] 3D Ocular Ultrasound Using Gaze Tracking on the Contralateral Eye: A Feasibility Study
    Afsham, Narges
    Najafi, Mohammad
    Abolmaesumi, Purang
    Rohling, Robert
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 65 - 72
  • [6] Strain analysis of cardiac tissues from 3D ultrasound images through speckle tracking
    Lanconelli, Nico
    Masetti, Simone
    Nardinocchi, Paola
    Teresi, Luciano
    Puddu, Paolo Emilio
    Torromeo, Concetta
    Giglio, Vincenzo
    2013 8TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS (ISPA), 2013, : 477 - +
  • [7] Intra-cardiac 2D US to 3D CT image registration
    Huang, Xishi
    Hill, Nicholas A.
    Ren, Jing
    Guiraudon, Gerard
    Peters, Terry M.
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [8] Iterative neuronavigation using 3D ultrasound - a feasibility study
    Lindner, D
    Trantakis, C
    Schmidtgen, A
    Grunst, G
    Arnold, S
    Meixensberger, E
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 619 - 624
  • [9] Enhancement of intra-cardiac flow-field data using adaptive Kernel filtering
    Shataneek Banerjee
    Amardip Ghosh
    Prasanta Pal
    Scientific Reports, 13 (1)
  • [10] Enhancement of intra-cardiac flow-field data using adaptive Kernel filtering
    Banerjee, Shataneek
    Ghosh, Amardip
    Pal, Prasanta
    SCIENTIFIC REPORTS, 2023, 13 (01):