Silicon carbide for high resolution X-ray detectors operating up to 100°C

被引:73
|
作者
Bertuccio, G
Casiraghi, R
Cetronio, A
Lanzieri, C
Nava, F
机构
[1] Politecn Milan, Dept Elect Engn & Informat Sci, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[3] Alenia Marconi Syst, I-00131 Rome, Italy
[4] Univ Modena, Dept Phys, I-41100 Modena, Italy
[5] Ist Nazl Fis Nucl, Sez Bologna, I-40126 Bologna, Italy
关键词
silicon carbides; radiation detectors; X-ray spectroscopy; high-temperature electronic devices;
D O I
10.1016/j.nima.2003.11.413
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work presents experimental results on the possibility of high resolution X-ray spectroscopy in a wide temperature range, from room temperature up to 100degreesC without any cooling system, using Silicon Carbide (SiC) detectors. This capability arises from the very low noise of SiC detectors at high temperature because of their extremely low-leakage current density (20 pA/cm(2), at 24degreesC and 1 nA/cm(2) at 107degreesC with mean electric fields of 120 kV/cm). Spectra of Am-241 acquired by a pixel SiC detector are reported with equivalent noise energies of 315 eV FWHM at 27degreesC and 797 eV FWHM at 100degreesC. The contributions of the different noise sources of the detector and of the front-end electronics are determined and analyzed. The potential for SiC X-ray detectors and open issues in SiC technology are highlighted. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:413 / 419
页数:7
相关论文
共 50 条
  • [31] High-resolution imaging silicon X-ray spectrometers
    Strüder, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (1-2): : 146 - 146
  • [32] Measurement of the Energy Resolution of Silicon X-Ray Detectors Using Absorption Edge Spectra
    S. M. Osadchii
    A. A. Petukhov
    V. B. Dunin
    [J]. Measurement Techniques, 2019, 62 : 465 - 469
  • [33] Measurement of the Energy Resolution of Silicon X-Ray Detectors Using Absorption Edge Spectra
    Osadchii, S. M.
    Petukhov, A. A.
    Dunin, V. B.
    [J]. MEASUREMENT TECHNIQUES, 2019, 62 (05) : 465 - 469
  • [34] Low-noise silicon carbide X-ray sensor with wide operating temperature range
    Bertuccio, G
    Casiraghi, R
    Cetronio, A
    Lanzieri, C
    Nava, F
    [J]. ELECTRONICS LETTERS, 2004, 40 (03) : 173 - 174
  • [35] X-ray silicon detectors for measuring hard X-ray radiation damage effects
    Wagner, D
    Halmagean, E
    Loukas, D
    Misiakos, K
    Tsoi, E
    Veron, A
    Ohanisian, M
    [J]. HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 296 - 304
  • [36] Electron-excited energy dispersive X-ray spectrometry at high speed and at high resolution: Silicon drift detectors and microcalorimeters
    Newbury, Dale E.
    [J]. MICROSCOPY AND MICROANALYSIS, 2006, 12 (06) : 527 - 537
  • [37] High-resolution phosphors as X-ray detectors for synchrotron radiation experiments
    Park, JK
    Kim, DH
    Kang, SS
    Cho, SH
    Mun, CW
    Nam, SH
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4690 - 4694
  • [38] Focal Spot Deblurring for High Resolution Direct Conversion X-ray Detectors
    Nagesh, S. V. Setlur
    Rana, R.
    Russ, M.
    Ionita, Ciprian N.
    Bednarek, D. R.
    Rudin, S.
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [39] APPLICATION OF HIGH-RESOLUTION SEMICONDUCTOR DETECTORS IN X-RAY EMISSION SPECTROGRAPHY
    BOWMAN, HR
    HYDE, EK
    THOMPSON, SG
    JARED, RC
    [J]. SCIENCE, 1966, 151 (3710) : 562 - &
  • [40] High-resolution for IAXO: MMC-based X-ray detectors
    Unger, D.
    Abeln, A.
    Enss, C.
    Fleischmann, A.
    Hengstler, D.
    Kempf, S.
    Gastaldo, L.
    [J]. JOURNAL OF INSTRUMENTATION, 2021, 16 (06)