An improved fabric-phase sorptive extraction protocol for the determination of seven parabens in human urine by HPLC-DAD

被引:29
|
作者
Rigkos, Georgios [1 ]
Alampanos, Vasileios [1 ]
Kabir, Abuzar [2 ]
Furton, Kenneth G. [2 ]
Roje, Zeljka [3 ]
Vrcek, Ivana Vinkovic [4 ]
Panderi, Irene [5 ]
Samanidou, Victoria [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Lab Analyt Chem, GR-54124 Thessaloniki, Greece
[2] Florida Int Univ, Dept Chem & Biochem, Int Forens Res Inst, Miami, FL 33199 USA
[3] Univ Hosp Dubrava, Dept Plast Reconstruct & Aesthet Surg, Zagreb, Croatia
[4] Inst Med Res & Occupat Hlth, Zagreb, Croatia
[5] Natl & Kapodistrtian Univ Athens Panepistimiopoli, Div Pharmaceut Chem, Lab Pharmaceut Anal, Fac Pharm, Athens, Greece
关键词
bioanalytical chemistry; fabric-phase sorptive extraction (FPSE); parabens; sample preparation; urine; LIQUID-LIQUID MICROEXTRACTION; SAMPLE PREPARATION; MASS-SPECTROMETRY; CHROMATOGRAPHY; EXPOSURE; ESTERS; MILK;
D O I
10.1002/bmc.4974
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved fabric-phase sorptive extraction (FPSE) protocol has been developed and validated herein for the simple, fast, sensitive and green determination of seven parabens-methyl paraben, ethyl paraben, propyl paraben, butyl paraben, isopropyl paraben, isobutyl paraben and benzyl paraben-in human urine samples by HPLC-DAD. The mobile phase consisted of ammonium acetate (0.05m) and acetonitrile, while total analysis time was 13.2 min. Sol-gel poly (tetrahydrofuran) coated FPSE membrane resulted in optimum extraction sensitivity for the seven parabens. The novel FPSE medium as well as the improved and faster sample preparation procedure resulted in lower limit of detection and quantitation values in comparison with previously reported methods. The separation was carried out using an RP-HPLC method with a Spherisorb C(18)column and a flow rate of 1.4 ml/min. The validation of the analytical method was carried out by means of linearity, precision, accuracy, selectivity, sensitivity and robustness. For all seven parabens, the limits of detection and quantitation were 0.003 and 0.01 mu g/ml, respectively. Relative recovery rates were between 86.3 and 104%, while RSD values were <12.6 and 19.3% for within- and between-day repeatability, respectively. The method was subsequently applied to real human urine samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Determination of commonly used herbicides in surface water using solid-phase extraction and dual-column HPLC-DAD
    Özhan, G
    Özden, S
    Alpertunga, B
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2005, 40 (06) : 827 - 840
  • [42] Determination of Intact Parabens in the Human Plasma of Cancer and Non-Cancer Patients Using a Validated Fabric Phase Sorptive Extraction Reversed-Phase Liquid Chromatography Method with UV Detection
    Parla, Anthi
    Zormpa, Eirini
    Paloumpis, Nikolaos
    Kabir, Abuzar
    Furton, Kenneth G.
    Roje, Zeljka
    Samanidou, Victoria
    Vrcek, Ivana Vinkovic
    Panderi, Irene
    MOLECULES, 2021, 26 (06):
  • [43] Magnetic Solid-Phase Extraction Followed by HPLC-DAD for Highly Sensitive Determination of Phthalate Esters in Edible Vegetable Oils
    Zhao, Yuanli
    Zhu, Zhenbao
    Liu, Jianghua
    Liu, Jichao
    Li, Guoliang
    FOOD ANALYTICAL METHODS, 2021, 14 (11) : 2375 - 2385
  • [44] Fabric phase sorptive extraction of monomers released from dental resins in alcoholic beverages prior to their HPLC-UV determination
    Nikolaou, Charalampia
    Kalogiouri, Natasa P.
    Mourouzis, Petros
    Kabir, Abuzar
    Furton, Kenneth
    Samanidou, Victoria F.
    MICROCHEMICAL JOURNAL, 2023, 191
  • [45] Fast SPE and HPLC-DAD determination of brucine in human urine using multi-walled carbon nanotubes modified with magnetic nanoparticles
    Feng, Zufei
    Yang, Rong
    Du, Baozhong
    JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 72 (08) : 862 - 869
  • [46] Solvent bar microextraction combined with HPLC-DAD and multivariate optimization for simultaneous determination of three antiarrhythmic drugs in human urine and plasma samples
    AL-Hashimi, Nabil N.
    Al-Degs, Yahya S.
    Al Momany, Enaam M. A.
    El-Sheikh, Amjad H.
    Alqudah, Abdelrahim M. A.
    Oqal, Muna K. A.
    Abdelghani, Jafar I.
    TALANTA OPEN, 2022, 6
  • [47] Salt-Induced Homogeneous Liquid-Liquid Microextraction of Piroxicam and Meloxicam from Human Urine Prior to Their Determination by HPLC-DAD
    Manousi, Natalia
    Tsiona, Sotiria, V
    Zacharis, Constantinos K.
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [48] Functionalized Multi Walled Carbon Nanotubes-Reinforced Hollow Fiber Solid/Liquid Phase Microextraction and HPLC-DAD for Determination of Phenazopyridine in Urine
    AL-Hashimi, Nabil N.
    Awwad, Anas, I
    AL-Hashimi, Aqeel N.
    Mansi, Man A.
    Shahin, Rand O.
    Hamed, Saja H.
    CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (05) : 447 - 455
  • [49] Sol-gel-graphene-based fabric-phase sorptive extraction for cow and human breast milk sample cleanup for screening bisphenol A and residual dental restorative material before analysis by HPLC with diode array detection
    Samanidou, Victoria
    Filippou, Olga
    Marinou, Eirini
    Kabir, Abuzar
    Furton, Kenneth G.
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (12) : 2612 - 2619
  • [50] Fabric phase sorptive extraction combined with high performance liquid chromatography for the determination of favipiravir in human plasma and breast milk
    Tiris, Gizem
    Gazioglu, Isil
    Furton, Kenneth G.
    Kabir, Abuzar
    Locatelli, Marcello
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 223