An improved fabric-phase sorptive extraction protocol for the determination of seven parabens in human urine by HPLC-DAD

被引:29
|
作者
Rigkos, Georgios [1 ]
Alampanos, Vasileios [1 ]
Kabir, Abuzar [2 ]
Furton, Kenneth G. [2 ]
Roje, Zeljka [3 ]
Vrcek, Ivana Vinkovic [4 ]
Panderi, Irene [5 ]
Samanidou, Victoria [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Lab Analyt Chem, GR-54124 Thessaloniki, Greece
[2] Florida Int Univ, Dept Chem & Biochem, Int Forens Res Inst, Miami, FL 33199 USA
[3] Univ Hosp Dubrava, Dept Plast Reconstruct & Aesthet Surg, Zagreb, Croatia
[4] Inst Med Res & Occupat Hlth, Zagreb, Croatia
[5] Natl & Kapodistrtian Univ Athens Panepistimiopoli, Div Pharmaceut Chem, Lab Pharmaceut Anal, Fac Pharm, Athens, Greece
关键词
bioanalytical chemistry; fabric-phase sorptive extraction (FPSE); parabens; sample preparation; urine; LIQUID-LIQUID MICROEXTRACTION; SAMPLE PREPARATION; MASS-SPECTROMETRY; CHROMATOGRAPHY; EXPOSURE; ESTERS; MILK;
D O I
10.1002/bmc.4974
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved fabric-phase sorptive extraction (FPSE) protocol has been developed and validated herein for the simple, fast, sensitive and green determination of seven parabens-methyl paraben, ethyl paraben, propyl paraben, butyl paraben, isopropyl paraben, isobutyl paraben and benzyl paraben-in human urine samples by HPLC-DAD. The mobile phase consisted of ammonium acetate (0.05m) and acetonitrile, while total analysis time was 13.2 min. Sol-gel poly (tetrahydrofuran) coated FPSE membrane resulted in optimum extraction sensitivity for the seven parabens. The novel FPSE medium as well as the improved and faster sample preparation procedure resulted in lower limit of detection and quantitation values in comparison with previously reported methods. The separation was carried out using an RP-HPLC method with a Spherisorb C(18)column and a flow rate of 1.4 ml/min. The validation of the analytical method was carried out by means of linearity, precision, accuracy, selectivity, sensitivity and robustness. For all seven parabens, the limits of detection and quantitation were 0.003 and 0.01 mu g/ml, respectively. Relative recovery rates were between 86.3 and 104%, while RSD values were <12.6 and 19.3% for within- and between-day repeatability, respectively. The method was subsequently applied to real human urine samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Fabric phase sorptive extraction for the isolation of five common antidepressants from human urine prior to HPLC-DAD analysis
    Lioupi, Artemis
    Kabir, Abuzar
    Furton, Kenneth G.
    Samanidou, Victoria
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1118 : 171 - 179
  • [2] Мagnet integrated fabric phase sorptive extraction (MI-FPSE) for the selective isolation of seven sulfonamides from human urine prior to HPLC-DAD analysis
    Tsompanopoulou, Glykeria N.
    Kabir, Abuzar
    Furton, Kenneth G.
    Kalogiouri, Natasa P.
    Samanidou, Victoria F.
    MICROCHEMICAL JOURNAL, 2024, 206
  • [3] Simultaneous determination of phenytoin and dextromethorphan in urine by solid-phase extraction and HPLC-DAD
    Santagati, NA
    Gotti, R
    Ronsisvalle, G
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (11) : 1157 - 1162
  • [4] Poly(tetrahydrofuran)-based fabric phase sorptive extraction combined with HPLC-UV for the determination of antihistamines in human urine
    Papadouli, Kyriaki
    Ntorkou, Marianna
    Manousi, Natalia
    Kabir, Abuzar
    Zacharis, Constantinos K.
    MICROCHEMICAL JOURNAL, 2023, 192
  • [5] Trace determination of parabens in cosmetics and personal care products using fabric-phase sorptive extraction and high-performance liquid chromatography with UV detection
    Kaur, Ramandeep
    Heena
    Kaur, Ripneel
    Grover, Aman
    Rani, Susheela
    Malik, Ashok Kumar
    Kabir, Abuzar
    Furton, Kenneth G.
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (13) : 2626 - 2635
  • [6] Molecularly imprinted pipette-tip solid phase extraction for selective determination of fluoroquinolones in human urine using HPLC-DAD
    de Oliveira, Hanna Leijoto
    Anacleto, Sara da Silva
    Maria da Silva, Anny Talita
    Pereira, Arnaldo Cesar
    Borges, Warley de Souza
    Figueiredo, Eduardo Costa
    Borges, Keyller Bastos
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 : 27 - 39
  • [7] Magnet integrated fabric phase sorptive extraction as a stand-alone extraction device for the monitoring of benzoyl urea insecticides in water samples by HPLC-DAD
    Manousi, Natalia
    Alampanos, Vasileios
    Ferracane, Antonio
    Efstratiadis, Georgios
    Kabir, Abuzar
    Furton, Kenneth G.
    Tranchida, Peter Q.
    Zachariadis, George A.
    Mondello, Luigi
    Rosenberg, Erwin
    Samanidou, Victoria F.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1672
  • [8] Fabric Phase Sorptive Extraction Combined with HPLC-UV for the Quantitation of Amphotericin B in Human Urine
    Asimakopoulou, Evmorfia
    Manousi, Natalia
    Anaxagorou, Nikoleta
    Kabir, Abuzar
    Furton, Kenneth G. G.
    Zacharis, Constantinos K. K.
    CHEMOSENSORS, 2022, 10 (12)
  • [9] Magnet Integrated Fabric Phase Sorptive Extraction for the Extraction of Resin Monomers from Human Urine Prior to HPLC Analysis
    Antoniou, Georgios
    Alampanos, Vasileios
    Kabir, Abuzar
    Zughaibi, Torki
    Furton, Kenneth G.
    Samanidou, Victoria
    SEPARATIONS, 2023, 10 (04)
  • [10] Simultaneous determination of seven phthallates and four parabens in cosmetic products using HPLC-DAD and GC-MS methods
    Shen, Hao-Yu
    Jiang, Hai-Liang
    Mao, Hong-Lei
    Pan, Gang
    Zhou, Lu
    Cao, Yun-Feng
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (01) : 48 - 54