Frequency doubling technology perimetry with the Humphrey Matrix 30-2 test

被引:40
|
作者
Brusini, P
Salvetat, ML
Zeppieri, M
Parisi, L
机构
[1] Santa Maria Misericordia Hosp, Dept Ophthalmol, I-33100 Udine, Italy
[2] Univ Udine, Dept Ophthalmol, I-33100 Udine, Italy
关键词
frequency doubling technology; Humphrey Matrix; standard automated perimetry; primary open-angle glaucoma; ocular hypertension;
D O I
10.1097/00061198-200604000-00001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the Humphrey Matrix 30-2 test in detecting functional glaucomatous damage. Patients and Methods: One eye in each of 60 healthy individuals, 108 patients with ocular hypertension (OHT), and 150 patients with preperimetric (48) or perimetric (102) high-tension primary open-angle glaucoma (POAG) were considered. Visual fields were assessed by the standard automated perimetry (SAP) Humphrey Field Analyzer 30-2, frequency doubling technology (FDT) N-30, and Humphrey Matrix 30-2 tests. Significantly abnormal points in the pattern deviation probability plot, testing time, sensitivity, specificity, and area tinder the receiver operating characteristic curve of the FDT tests were evaluated. Results: FDT revealed a significantly greater percentage of depressed points than did SAP in OHT and preperimetric POAG eyes. The FDT-N-30 test showed a significantly greater percentage of areas with P < 5% in the OHT, preperimetric POAG, and early POAG groups. The Matrix-30-2 test provided an area under the receiver operating characteristic curve slightly lower than the FDT-N-30 test in the preperimetric POAG group, and significantly greater in the perimetric POAG group. Conclusions: FDT perimetry appeared more sensitive than SAP in detecting early glaucomatous VF loss. The FDT-N-30 test showed a slightly higher ability to detect early glaucomatous damage in patients at risk for the development of glaucoma, whereas the Matrix-30-2 test provided a more detailed characterization of the glaucomatous VF loss pattern, although it required 30% more time.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 50 条
  • [41] Mechanisms isolated by frequency-doubling technology perimetry
    Anderson, AJ
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (02) : 398 - 401
  • [42] Variability components of standard automated perimetry and frequency-doubling technology perimetry
    Spry, PGD
    Johnson, CA
    McKendrick, AM
    Turpin, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (06) : 1404 - 1410
  • [43] Comparison of 30-2 Standard and Fast programs of Swedish Interactive Threshold Algorithm of Humphrey Field Analyzer for perimetry in patients with intracranial tumors
    Singh, Manav Deep
    Jain, Kanika
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (11) : 1198 - 1202
  • [44] Standard Automated Perimetry versus Matrix Frequency Doubling Technology Perimetry in Subjects with Ocular Hypertension and Healthy Control Subjects
    Lamparter, Julia
    Aliyeva, Shakhsanam
    Schulze, Andreas
    Berres, Manfred
    Pfeiffer, Norbert
    Hoffmann, Esther M.
    PLOS ONE, 2013, 8 (02):
  • [45] Spatial relationship of defects in frequency doubling technology perimetry and standard achromatic perimetry
    Pascual, JP
    Sample, PA
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U489 - U489
  • [46] Diagnostic accuracy of the Matrix 24-2 and original N-30 frequency-doubling technology tests compared with standard automated perimetry
    Racette, Lyne
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Ng, Diana
    Weinreb, Robert N.
    Sample, Pamela A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (03) : 954 - 960
  • [47] Humphrey matrix frequency doubling technology perimetry and optical coherence tomography measurement of the retinal nerve fiber layer thickness in both normal and ocular hypertensive subjects
    Mastropasqua, Leonardo
    Brusini, Paolo
    Carpineto, Paolo
    Ciancaglini, Marco
    Di Antonio, Luca
    Zeppieri, Marco W.
    Parisi, Lucia
    JOURNAL OF GLAUCOMA, 2006, 15 (04) : 328 - 335
  • [48] Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma
    Artes, PH
    Hutchison, DM
    Nicolela, MT
    LeBlanc, RP
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2451 - 2457
  • [49] Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice
    Wadood, AC
    Azuara-Blanco, A
    Aspinall, P
    Taguri, A
    King, AJW
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (03) : 327 - 332
  • [50] Frequency doubling technology perimetry 2 (24-2) in the evaluation of homonymous hemianopias
    Taravati, P
    Woodward, K
    Carolan, JA
    Huang, CQ
    Redline, DE
    Keltner, JL
    Wall, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U317 - U317