Simulation-based reconstruction of absolute activities from the 99mTc/111In dual-isotope SPECT/CT: phantom experiments and imaging of neuroendocrine tumors

被引:3
|
作者
Shcherbinin, S. [1 ]
Chamoiseau, S. [2 ]
Celler, A. [1 ]
机构
[1] Univ British Columbia, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
[2] Ctr Hosp Bigorre, Serv Med Nucl, F-65013 Tarbes, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 10期
关键词
MONTE-CARLO; SCATTER CORRECTION; METASTASES; INFECTION; ENERGY;
D O I
10.1088/0031-9155/58/10/3339
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigate the quantitative accuracy of the reconstruction of absolute Tc-99m and In-111 activities from Tc-99m/In-111 dual-isotope SPECT studies. The separate reconstruction of two images is achieved by applying Monte Carlo simulation-based corrections for self-scatter and cross-talk between energy windows. For method evaluation, a series of Tc-99m/In-111 physical phantom experiments was performed using a clinical SPECT/CT camera. The containers were filled with different ratios of Tc-99m and In-111 activities to create cross-talk with varying severity levels. In addition, we illustrate the performance of our method by reconstructing images from four simultaneous Tc-99m/In-111 SPECT/CT studies of neuroendocrine patients. Similarly to the phantom experiments, clinical cases provide examples with different severity of cross-talk. Phantom experiments showed that Monte Carlo simulation-based corrections improved both quantitative accuracy and visual properties of Tc-99m and In-111 images. While the errors of absolute activities for both tracers in six containers ranged from 16% to 75% if no corrections for self-scatter and cross-talk were applied, these errors decreased to below 10% when images were reconstructed with the aforementioned corrections. These activities were measured using regions of interest larger than the true sizes of the containers in order to account for the spill-out effect. Analysis of patient studies confirmed that accurate simulation-based compensations improved resolution and contrast for both Tc-99m and In-111 images.
引用
收藏
页码:3339 / 3357
页数:19
相关论文
共 30 条
  • [21] Molecular imaging of angiogenesis after myocardial infarction by 111In-DTPA-cNGR and 99mTc-sestamibi dual-isotope myocardial SPECT
    Geert Hendrikx
    Marijke De Saint-Hubert
    Ingrid Dijkgraaf
    Matthias Bauwens
    Kim Douma
    Roel Wierts
    Ivo Pooters
    Nynke MS Van den Akker
    Tilman M Hackeng
    Mark J Post
    Felix M Mottaghy
    EJNMMI Research, 5
  • [22] Simultaneous 99mTc/201Tl dual-isotope SPECT with Monte Carlo-based down-scatter correction.
    de Jong, HW
    Beekman, FJ
    Viergever, MA
    van Rijk, PP
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 53P - 53P
  • [23] Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal SPECT-PET/CT system
    Takayuki Shibutani
    Masahisa Onoguchi
    Takayuki Kanno
    Seigo Kinuya
    Physical and Engineering Sciences in Medicine, 2024, 47 : 135 - 142
  • [24] Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal SPECT-PET/CT system
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Kanno, Takayuki
    Kinuya, Seigo
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (01) : 135 - 142
  • [25] Simultaneous 166Ho/99mTc dual-isotope SPECT with Monte Carlo-based downscatter correction for automatic liver dosimetry in radioembolization
    R. van Rooij
    A. J. A. T. Braat
    H. W. A. M. de Jong
    M. G. E. H. Lam
    EJNMMI Physics, 7
  • [26] Simultaneous 166Ho/99mTc dual-isotope SPECT with Monte Carlo-based downscatter correction for automatic liver dosimetry in radioembolization
    van Rooij, R.
    Braat, A. J. A. T.
    de Jong, H. W. A. M.
    Lam, M. G. E. H.
    EJNMMI PHYSICS, 2020, 7 (01)
  • [27] Scatter correction based on an artificial neural network for99mTc and123I dual-isotope SPECT in myocardial and brain imaging
    Jingming Bai
    Jun Hashimoto
    Koichi Ogawa
    Tadaki Nakahara
    Takayuki Suzuki
    Atsushi Kubo
    Annals of Nuclear Medicine, 2007, 21
  • [28] Fast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging
    Ouyang, Jinsong
    El Fakhri, Georges
    Moore, Stephen C.
    Kijewski, Marie F.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2251 - 2256
  • [29] Simultaneous dual-isotope 123I/99mTc acquisition using CZT-based cameras: Toward a one-stop-shop SPECT in heart failure patients
    Blaire, T.
    Bailliez, A.
    Ben Bouallegue, F.
    Bellevre, D.
    Agostini, D.
    Manrique, A.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2018, 42 (01): : 3 - 8
  • [30] SIMULTANEOUS 99mTc AND 123I DUAL-ISOTOPE BRAIN STRIATAL PHANTOM SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY: VALIDATION OF 99mTc-TRODAT-1 AND 123I-IBZM SIMULTANEOUS DOPAMINE SYSTEM BRAIN IMAGING
    Kao, Pan-Fu
    Wey, Shiaw-Pyng
    Yang, An-Shoei
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2009, 25 (11): : 601 - 606