Location estimation of coating defects and mitigation of induced AC voltages along buried gas pipeline

被引:8
|
作者
Kamar, Ahmed R. [1 ]
Abd-Elhady, Amr M. [2 ]
Sabiha, Nehmdoh A. [2 ]
Izzularab, Mohamed A. [2 ]
机构
[1] Egyptian Nat Gas Co Gasco, Cairo, Egypt
[2] Minoufiya Univ, Dept Elect Engn, Fac Engn, Shibin Al Kawm 32511, Egypt
关键词
maintenance engineering; pipelines; electromagnetic induction; flaw detection; power overhead lines; protective coatings; voltage measurement; coating defect estimation; induced AC voltage mitigation; buried gas pipeline; alternating current voltage; current density; overhead transmission line; pipeline induced AC voltages; least square method; polarisation cells; pipeline lifetime; maintenance cost; TRANSMISSION-LINES; POWER-LINES; INTERFERENCE;
D O I
10.1049/iet-smt.2017.0157
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, determining the location of coating defects and severities is evaluated using measurements along the Jordanian buried gas pipeline. Induced alternating current (AC) voltages and current densities along the pipeline are investigated using analytical and practical data under normal operation of the overhead transmission line. Since the induced AC voltages depend on the load currents, it is worthy to determine the actual load current during the lifetime of the pipeline. Accordingly, the forecasting of pipeline-induced AC voltages is investigated using the least square method. The investigation is carried out in order to expect the future effects on the gas pipeline. The mitigation of induced AC voltage based on inserting polarisation cells (PCs) along the pipeline is evaluated. The results show that an agreement between the measured and calculated induced AC voltages is achieved with and without PCs. Based on the forecasting of induced AC voltages and current density along the pipeline, determining the number of PCs and allocations is suggested for the future years. This study increases the lifetime of the pipeline as well as decreases the maintenance cost.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 31 条
  • [21] Evaluation and Mitigation of Underground Gas Pipeline Coating Stress Due to Nearby Lightning Stroke
    Mousa, Mohammed Imran
    Abdul-Malek, Zulkurnain
    Ibrahim, Visa Musa
    Elgayar, Ali I.
    Nawawi, Zainuddin
    Sidik, Muhammad Abu Bakar
    Jambak, Muhammad Irfan
    2017 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND COMPUTER SCIENCE (ICECOS), 2017, : 275 - 279
  • [22] PREDICTION METHOD FOR BURIED PIPELINE VOLTAGES DUE TO 60 Hz AC INDUCTIVE COUPLING - 2. FIELD TEST VERIFICATION.
    Dabkowski, John
    Taflove, Allen
    1978,
  • [23] AC CORROSION PHENOMENON AND MITIGATION IN BURIED PIPELINE DUE TO VERY-HIGH-VOLTAGE (VHV) OVERHEAD TRANSMISSION LINE EFFECT
    Gherbia, Abdelali
    Djekidel, Rabah
    Sid-Ahmed, Bessedik
    Djillali, Mahi
    FACTA UNIVERSITATIS-SERIES ELECTRONICS AND ENERGETICS, 2023, 36 (03) : 427 - 447
  • [24] PREDICTION METHOD FOR BURIED PIPELINE VOLTAGES DUE TO 60-HZ AC INDUCTIVE COUPLING .2. FIELD-TEST VERIFICATION
    DABKOWSKI, J
    TAFLOVE, A
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (03): : 788 - 794
  • [25] Model for remaining strength estimation of a corroded pipeline with interacting defects for oil and gas operations
    Amandi, K. U.
    Diennuodeke, E. O.
    Briggs, T. A.
    COGENT ENGINEERING, 2019, 6 (01):
  • [26] Case Studies of the Electromagnetic Influence of AC Transmission Lines on the Adjacent Buried Oil/gas Pipeline Under Steady State
    Mo B.
    Huang W.
    Zhou S.
    Wei J.
    Luo Y.
    Kang J.
    Sun T.
    Guo G.
    Luo, Yongfen (yfluo@mail.xjtu.edu.cn), 1600, Chinese Society for Electrical Engineering (40): : 6035 - 6044
  • [27] Mitigation of AC induced voltage on the metallic pipeline based-on the optimal design of KOH-Polarization cells
    Al-Gabalawy, Mostafa
    Mostafa, Mohamed A.
    Hamza, Abdel Salam
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 194
  • [28] Numerical Experiments of Dynamic Response of Buried Gas Pipeline under the Action of Seismic Waves Induced by Tunnel Blasting
    Zheng S.
    Yang L.
    1600, Science Press (52): : 264 - 271
  • [29] Lightning Location and Peak Current Estimation From Lightning-Induced Voltages on Transmission Lines With a Machine Learning Approach
    Nicora, Martino
    Tucci, Mauro
    Barmada, Sami
    Brignone, Massimo
    Procopio, Renato
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2024, 66 (03) : 890 - 899
  • [30] Effects of stray AC on corrosion of 3-layer polyethylene coated X70 pipeline steel and cathodic delamination of coating with defects in 3.5 wt-% NaCl solution
    Wang, Xinhua
    Xu, Cheng
    Chen, Yingchun
    Tu, Chengyuan
    Wang, Zuquan
    Song, Xuting
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 53 (03) : 214 - 225