Location estimation of coating defects and mitigation of induced AC voltages along buried gas pipeline

被引:8
|
作者
Kamar, Ahmed R. [1 ]
Abd-Elhady, Amr M. [2 ]
Sabiha, Nehmdoh A. [2 ]
Izzularab, Mohamed A. [2 ]
机构
[1] Egyptian Nat Gas Co Gasco, Cairo, Egypt
[2] Minoufiya Univ, Dept Elect Engn, Fac Engn, Shibin Al Kawm 32511, Egypt
关键词
maintenance engineering; pipelines; electromagnetic induction; flaw detection; power overhead lines; protective coatings; voltage measurement; coating defect estimation; induced AC voltage mitigation; buried gas pipeline; alternating current voltage; current density; overhead transmission line; pipeline induced AC voltages; least square method; polarisation cells; pipeline lifetime; maintenance cost; TRANSMISSION-LINES; POWER-LINES; INTERFERENCE;
D O I
10.1049/iet-smt.2017.0157
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, determining the location of coating defects and severities is evaluated using measurements along the Jordanian buried gas pipeline. Induced alternating current (AC) voltages and current densities along the pipeline are investigated using analytical and practical data under normal operation of the overhead transmission line. Since the induced AC voltages depend on the load currents, it is worthy to determine the actual load current during the lifetime of the pipeline. Accordingly, the forecasting of pipeline-induced AC voltages is investigated using the least square method. The investigation is carried out in order to expect the future effects on the gas pipeline. The mitigation of induced AC voltage based on inserting polarisation cells (PCs) along the pipeline is evaluated. The results show that an agreement between the measured and calculated induced AC voltages is achieved with and without PCs. Based on the forecasting of induced AC voltages and current density along the pipeline, determining the number of PCs and allocations is suggested for the future years. This study increases the lifetime of the pipeline as well as decreases the maintenance cost.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 31 条
  • [1] Mitigation of induced voltages and AC corrosion effects on buried gas pipeline near to OHTL under normal and fault conditions
    Abdel-Gawad, Nagat M. K.
    El Dein, Adel Z.
    Magdy, Mohamed
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 127 : 297 - 306
  • [2] MITIGATION OF INDUCED AC ON A BURIED OIL PIPELINE ALONG POWER LINE RIGHT-OF-WAY
    ROBINSON, HC
    ROG, JW
    MATERIALS PERFORMANCE, 1974, 13 (05) : 27 - 29
  • [3] MITIGATION OF INDUCED VOLTAGES ON BURIED PIPELINES
    DABKOWSKI, J
    MATERIALS PERFORMANCE, 1981, 20 (01) : 9 - 15
  • [4] Mitigation of induced voltages on buried pipelines
    Dabkowski, J., 1600, NACE International (56):
  • [5] Mitigation of Induced Voltages on Buried Pipelines
    Dabkowski, J.
    MATERIALS PERFORMANCE, 2017, 56 (12) : 32 - 39
  • [6] MITIGATION OF BURIED PIPELINE VOLTAGES DUE TO 60 Hz AC INDUCTIVE COUPLING PART II - PIPELINE GROUNDING METHODS.
    Dabkowski, John
    Taflove, Allen
    1979,
  • [7] Evaluation of induced AC voltages in underground metallic pipeline
    Micu, Dan D.
    Czumbil, Levente
    Christoforidis, Georgios C.
    Ceclan, Andrei
    Stet, Denisa
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2012, 31 (04) : 1133 - 1143
  • [8] CALCULATING TEMPERATURE PROFILE ALONG A BURIED GAS PIPELINE
    HAYNES, CD
    PIPELINE & GAS JOURNAL, 1974, 201 (06) : 48 - &
  • [9] STUDY ON LEAK LOCATION TECHNOLOGY FOR BURIED GAS PIPELINE
    Jiao, Yang
    Li, Guang-Hai
    Sun, Guang-Kai
    Zhu, Ying-Kui
    Zhao, Yu-Bo
    PROCEEDINGS OF 2009 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, 2009, : 492 - +
  • [10] ANALYSIS AND TREATMENT OF DEFECTS ON THE BURIED CIVIL GAS PIPELINE
    Wang, Jielu
    Li, Wei
    Hou, Shaoxing
    PROCEEDINGS OF ASME 2021 PRESSURE VESSELS AND PIPING CONFERENCE (PVP2021), VOL 1, 2021,