Forced Convection Heat Transfer in Spray Formed Copper and Nickel Foam Heat Exchanger Tubes

被引:14
|
作者
Tsolas, Nicholas [1 ]
Chandra, Sanjeev [1 ]
机构
[1] Univ Toronto, Ctr Adv Coating Technol, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
metal foams; heat exchangers; heat transfer enhancement; thermal spraying; FLOW;
D O I
10.1115/1.4006015
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermal spray coating process was used to deposit dense 2 mm thick metal skins on the surfaces of square cross-section channels (300 mm x 20 mm x 20 mm) of nickel and copper foams with 10 and 40 PPI (pores per inch) pore densities. A heater was wrapped around the channels to apply surface heat-fluxes varying from 427 to 6846 W/m(2). Compressed air was blown through the channels at flow rates of 5-80 l/min. Foam and fluid temperature distributions along the length of the channel and the pressure drop across it were measured. The foam was modeled as a porous medium and properties such as permeability K and inertial coefficient C-F were determined from the experimental data. Local and average convective heat transfer coefficients were calculated from air and foam temperature measurements. Nusselt numbers were calculated and correlated in terms of the Reynolds, Prandtl, and Darcy numbers. Heat transfer to air flowing through a 10 PPI foam channel was shown to have increased nearly seven times compared to that of hollow tube with the same dimensions. [DOI: 10.1115/1.4006015]