Kinetic aspects of hollow fiber liquid-phase microextraction and electromembrane extraction

被引:76
|
作者
Gjelstad, Astrid [1 ]
Jensen, Henrik [2 ]
Rasmussen, Knut Einar [1 ]
Pedersen-Bjergaard, Stig [1 ,2 ]
机构
[1] Univ Oslo, Sch Pharm, N-0316 Oslo, Norway
[2] Univ Copenhagen, Fac Pharmaceut Sci, Dept Pharmaceut & Analyt Chem, DK-2100 Copenhagen, Denmark
关键词
Hollow fiber liquid-phase microextraction; Electromembrane extraction; Supported liquid membrane; Extraction kinetics; Basic drugs; ELECTROKINETIC MIGRATION; SAMPLE PREPARATION; CAPILLARY-ELECTROPHORESIS; BIOLOGICAL-FLUIDS; BASIC DRUGS; MEMBRANE; CHEMISTRY; FIELDS;
D O I
10.1016/j.aca.2011.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, extraction kinetics was investigated experimentally and theoretically in hollow fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) with the basic drugs droperidol, haloperidol, nortriptyline, clomipramine, and clemastine as model analytes. In HF-LPME, the analytes were extracted by passive diffusion from an alkaline sample, through a (organic) supported liquid membrane (SLM) and into an acidic acceptor solution. In EME, the analytes were extracted by electrokinetic migration from an acidic sample, through the SLM, and into an acidic acceptor solution by application of an electrical potential across the SLM. In both HF-LPME and EME, the sample (donor solution) was found to be rapidly depleted for analyte. In HF-LPME, the mass transfer across the SLM was slow, and this was found to be the rate limiting step of HF-LPME. This finding is in contrast to earlier discussions in the literature suggesting that mass transfer across the boundary layer at the donor-SLM interface is the rate limiting step of HF-LPME. In EME, mass transfer across the SLM was much more rapid due to electrokinetic migration. Nevertheless, mass transfer across the SLM was rate limiting even in EME. Theoretical models were developed to describe the kinetics in HF-LPME, in agreement with the experimental findings. In HF-LPME, the extraction efficiency was found to be maintained even if pH in the donor solution was lowered from 10 to 7-8, which was below the pK(a)-value for several of the analytes. Similarly, in EME, the extraction efficiency was found to be maintained even if pH in the donor solution increased from 4 to 11, which was above the pk(a)-value for several of the analytes. The two latter experiments suggested that both techniques may be used to effectively extract analytes from samples in a broader pH range as compared to the pH range recommended in the literature. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 50 条
  • [31] Liquid-phase microextraction with porous hollow fibers, a miniaturized and highly flexible format for liquid-liquid extraction
    Pedersen-Bjergaard, Stig
    Rasmussen, Knut Einar
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 132 - 142
  • [32] Hollow fiber supported ionic liquid liquid-phase microextraction for determination of parathion in environmental water sample
    Zhou, Bo
    Huang, Dushu
    Xu, Shijuan
    Wu, Na
    Liu, Wei
    ADVANCED RESEARCH ON MATERIAL ENGINEERING, CHEMISTRY, BIOINFORMATICS III, 2014, 830 : 319 - 322
  • [33] Kinetic calibration for automated headspace liquid-phase microextraction
    Ouyang, GF
    Zhao, WN
    Pawliszyn, J
    ANALYTICAL CHEMISTRY, 2005, 77 (24) : 8122 - 8128
  • [34] Comparison of two extraction methods for the determination of selective serotonin reuptake inhibitors in sewage sludge by hollow fiber liquid-phase microextraction
    Sagrista, Ester
    Manuel Cortes, Jose
    Larsson, Estelle
    Salvado, Victoria
    Hidalgo, Manuela
    Jonsson, Jan Ake
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (18) : 2460 - 2468
  • [35] Supported liquid membranes in hollow fiber liquid-phase microextraction (LPME) -: Practical considerations in the three-phase mode
    Bardstu, Kari Folde
    Ho, Tung Si
    Rasmussen, Knut Einar
    Pedersen-Bjergaard, Stig
    Jonsson, Jan Ake
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (09) : 1364 - 1370
  • [36] Hollow-fiber liquid-phase microextraction for the determination of natural and synthetic estrogens in milk samples
    Socas-Rodriguez, Barbara
    Asensio-Ramos, Maria
    Hernandez-Borges, Javier
    Angel Rodriguez-Delgado, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1313 : 175 - 184
  • [37] Reversed lipid micellar hollow-fiber liquid-phase microextraction of rotigotine in rat plasma
    Bai, Jie
    Xie, Li-yuan
    Yang, Li
    Wang, Run-qin
    Chen, Xuan
    Hu, Shuang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1178
  • [38] Hollow fiber-mediated liquid-phase microextraction of chemical warfare agents from water
    Dubey, DK
    Pardasani, D
    Gupta, AK
    Palit, M
    Kanaujia, PK
    Tak, V
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1107 (1-2) : 29 - 35
  • [39] Determination of metal ions by ultrasound-assisted hollow fiber liquid-phase microextraction technique
    Tu, YuJiao
    Wu, Haizhi
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 (01): : 151 - 156
  • [40] Efficiency of Hollow Fiber Liquid-Phase Microextraction Chromatography Methods in the Separation of Organic Compounds: A Review
    Alsharif, Ali Mohamed Ali
    Tan, Guan-Huat
    Choo, Yeun-Mun
    Lawal, Abubakar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (03) : 378 - 391