Performance of a Ge-BGO Compton-suppression spectrometer and its application to photon activation analysis

被引:5
|
作者
Fukuda, K [1 ]
Ohkuma, J [1 ]
Asano, T [1 ]
Satoh, Y [1 ]
机构
[1] OSAKA UNIV, INST SCI & IND RES, OSAKA 567, JAPAN
基金
日本科学技术振兴机构;
关键词
D O I
10.1016/0168-583X(96)00206-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Compton-suppression spectrometer, consisting of a pure Ge detector and EGO shield detectors is described. A cylindrical symmetry type of the shield detector configuration, with the Ge detector inserted on the symmetry axis, has been designed. The Compton-suppression factor is 6.0 for the photopeak of Co-60 at 1332.5 keV. The peak-to-Compton ratio for the peak is 42:1 when the BGO detectors are used as a passive shield only, and is 250:1 in the suppression mode. Photon activation analysis with this detector has been made for the determination of trace elements in a bulk dysprosium sample. The signal-to-noise ratio for detecting trace elements in the sample has been improved by a factor from 1.3 to 3.1 by Compton suppression compared with that obtained in the non-suppression mode.
引用
收藏
页码:379 / 386
页数:8
相关论文
共 27 条
  • [21] Compton suppression instrumental neutron activation analysis performance in determining trace- and minor-element contents in foodstuff
    M. C. Freitas
    A. M. G. Pacheco
    M. A. Bacchi
    I. Dionísio
    S. Landsberger
    J. Braisted
    E. A. N. Fernandes
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 149 - 156
  • [22] GE(LI)-DETECTOR WITH SEPARATED SENSITIVE REGIONS AND ITS APPLICATION FOR NEUTRON-ACTIVATION ANALYSIS
    AKINSHIN, BK
    MARGOLIN, EM
    PAKHOMOV, EE
    PAKHOMOV.AL
    POLYTSYA, OP
    SOTSKOV, YP
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (04): : 71 - 75
  • [24] APPLICATION OF EPITHERMAL NEUTRON-ACTIVATION IN MULTIELEMENT ANALYSIS OF SILICATE ROCKS EMPLOYING BOTH COAXIAL GE(LI) AND LOW-ENERGY PHOTON DETECTOR SYSTEMS
    BAEDECKER, PA
    ROWE, JJ
    STEINNES, E
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1977, 40 (1-2): : 115 - 146
  • [26] Development of Small Sized High Performance Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-TOF MS) and Its Application in VOCs Analysis in Exhaled Gas
    Zhao, Zhong-Jun
    He, Fei-Yao
    Guo, Xing
    Li, Wen-Wen
    Dai, Jian-Xiong
    Fu, Yu
    Li, Hong
    Deng, Fu-Long
    Pu, Juan
    Yang, Yan-Ting
    Wang, Xu
    Duan, Yi-Xiang
    Journal of Chinese Mass Spectrometry Society, 2021, 42 (03) : 285 - 293
  • [27] Development and validation of a high-throughput method for the quantitative analysis of felodipine in human plasma using high-performance liquid chromatography with mass/mass spectrometer and its application to a bioequivalence study in healthy male Korean subjects
    Kim S.-H.