Microfocus X-ray Tube Based on CNT Array

被引:0
|
作者
Chen, Zexiang [1 ]
Wang, Zhihui [1 ]
Hu, Tianyong [1 ]
Zeng, Yugong [1 ]
Tang, Ningjiang [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Optoeletron Informat, Chengdu 610054, Peoples R China
关键词
X-ray tube; carbon nanotube; field emission; microwave plasma CVD; microfocus;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A macro-focus X-ray tube with CNT emitters was successfully developed. An anode current of 1.15mA was collected when the copper grid gate voltage was 2.7kV. A very small x-ray focal spot size with less than 39 mu m can be achieved, which could potentially produce very high special resolution X-ray image.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] MICROFOCUS X-RAY MAGNIFICATION EQUIPMENT
    ISAACSON, B
    MATERIALS EVALUATION, 1983, 41 (02) : A10 - A10
  • [32] Microfocus X-ray spectra measurement
    Rheinlander, Jorgen
    Gerward, Leif
    Lindegaard-Andersen, Asger
    Larsen, Jens
    Journal of X-Ray Science and Technology, 1992, 3 (03)
  • [33] Microfocus X-ray seeds separator
    Gryaznov, A. Yu
    Staroverov, N. E.
    Kholopova, E. D.
    Guk, K. K.
    4TH INTERNATIONAL CONFERENCE ON X-RAY AND ELECTROVACUUM TECHNIQUE, 2017, 2018, 967
  • [34] Smart X-ray tube based on CNT emitters for stationary tomosynthesis examination system
    Choi, Sungyoul
    Jeong, Jin-Woo
    Kang, Jun-Tae
    Kim, Jae-Woo
    Song, Yoon-Ho
    2011 24TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2011, : 185 - 186
  • [35] Development of 120 kV CNT-based digital X-ray tube for Fluoroscopy
    Gupta, Amar Prasad
    Jang, Jaekyu
    Park, Keunhwa
    Lee, Hanna
    Seo, Deokwon
    Sharma, Mrinal Bhusal
    Jung, Jaeik
    Park, YoungKuk
    Yeo, Seung Jun
    Ahn, Jeung Sun
    Ryu, Jehwang
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [36] Study of the Dynamics of Heating Anode Units in a Maskless Nanolithograph Based on an Array of Microfocus X-Ray Tubes
    Glagolev, P. Yu.
    Demin, G. D.
    Djuzhev, N. A.
    Makhiboroda, M. A.
    Filippov, N. A.
    TECHNICAL PHYSICS, 2024, 69 (02) : 232 - 242
  • [37] Experimental setup and the system performance for single-grid-based phase-contrast x-ray imaging (PCXI) with a microfocus x-ray tube
    Lim, Hyunwoo
    Park, Yeonok
    Cho, Hyosung
    Je, Uikyu
    Hong, Daeki
    Park, Chulkyu
    Woo, Taeho
    Lee, Minsik
    Kim, Jinsoo
    Chung, Nagkun
    Kim, Jinwon
    Kim, Jinguk
    OPTICS COMMUNICATIONS, 2015, 348 : 85 - 89
  • [38] A comparison of a microfocus X-ray source and a conventional sealed tube for crystal structure determination
    Schulz, Thomas
    Meindl, Kathrin
    Leusser, Dirk
    Stern, Daniel
    Graf, Juergen
    Michaelsen, Carsten
    Ruf, Michael
    Sheldrick, George M.
    Stalke, Dietmar
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2009, 42 : 885 - 891
  • [39] Transmission-type Window of HFCVD Diamond Film for Microfocus X-ray Tube
    Zheng, Lei
    Liu, Huarong
    Wang, Junting
    Proceedings of the 2016 4th International Conference on Mechanical Materials and Manufacturing Engineering (MMME 2016), 2016, 79 : 641 - 644
  • [40] Pushing the Limits of Microfocus X-Ray Sealed Tube Sources for Biological and Chemical Crystallography
    Graf, J.
    Stuerzer, T.
    Benning, M.
    Ott, H.
    Radcliffe, P.
    Schmidt-May, J.
    Michaelsen, C.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2020, 76 : A103 - A103