Numerical and experimental investigation of pulsatile hemodynamics in the total cavopulmonary connection

被引:14
|
作者
Tang, Elaine [1 ]
Haggerty, Christopher M. [2 ,3 ]
Khiabani, Reza H. [2 ,3 ]
de Zelicourt, Diane [2 ,3 ]
Kanter, Jessica [2 ,3 ]
Sotiropoulos, Fotis [4 ]
Fogel, Mark A. [5 ]
Yoganathan, Ajit P. [2 ,3 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[3] Emory Univ, Atlanta, GA 30332 USA
[4] Univ Minnesota, Dept Civil Engn, Minneapolis, MN 55455 USA
[5] Childrens Hosp Philadelphia, Div Pediat Cardiol, Philadelphia, PA 19104 USA
关键词
Fontan procedure; Computational fluid dynamics; Digital particle image velocimetry; In vitro validation; PULMONARY ARTERIOVENOUS-MALFORMATIONS; SURGICAL REPAIR; CFD SIMULATIONS; FLOW; FONTAN; RESPIRATION; ANATOMIES; EXERCISE; BLOOD;
D O I
10.1016/j.jbiomech.2012.11.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Computational fluid dynamics (CFD) tools have been extensively applied to study the hemodynamics in the total cavopulmonary connection (TCPC) in patients with only a single functioning ventricle. Without the contraction of a sub-pulmonary ventricle, pulsatility of flow through this connection is low and variable across patients, which is usually neglected in most numerical modeling studies. Recent studies suggest that such pulsatility can be non-negligible and can be important in hemodynamic predictions. The goal of this work is to compare the results of an in-house numerical methodology for simulating pulsatile TCPC flow with experimental results. Digital particle image velocimetry (DPIV) was acquired on TCPC in vitro models to evaluate the capability of the CFD tool in predicting pulsatile TCPC flow fields. In vitro hemodynamic measurements were used to compare the numerical prediction of power loss across the connection. The results demonstrated the complexity of the pulsatile TCPC flow fields and the validity of the numerical approach in simulating pulsatile TCPC flow dynamics in both idealized and complex patient specific models. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:373 / 382
页数:10
相关论文
共 50 条
  • [21] Effect of fenestration on the sub-diaphragmatic venous hemodynamics in the total-cavopulmonary connection
    Hsia, TY
    Khambadkone, S
    Redington, AN
    de Leval, MR
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (06) : 785 - 792
  • [22] Power dissipation associated with surgical operations' hemodynamics: Critical issues and application to the total cavopulmonary connection
    Grigioni, M
    D'Avenio, G
    Amodeo, A
    Di Donato, RM
    JOURNAL OF BIOMECHANICS, 2006, 39 (09) : 1583 - 1594
  • [23] A skeletalized representation of the total cavopulmonary connection
    Krishnankuttyrema, Resmi
    Dasi, Lakshnni Prasad
    Pekkan, Kerem
    Sundareswaran, Kartik
    Kitajima, Hiroumi D.
    Yoganathan, Ajit P.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 571 - 572
  • [24] Power dissipation in the total cavopulmonary connection
    Grigioni, M
    Amodeo, A
    Daniele, C
    D'Avenio, G
    Oppido, G
    Di Donato, R
    Barbaro, V
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 881 - 884
  • [25] Sildenafil Before Total Cavopulmonary Connection
    Naranjo-Ugalde, Alfredo M.
    Rivera-Ladino, Katia M.
    Consuegra-Chuarey, Maria T.
    Marcano-Sanz, Luis E.
    Palenzuela Lopez, Herminia
    REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (01): : 71 - 71
  • [26] MODIFIED TECHNIQUE FOR TOTAL CAVOPULMONARY CONNECTION
    GREGORI, F
    SILVA, SS
    RIBEIRO, IA
    CORDEIRO, CO
    COUTO, WJ
    ANNALS OF THORACIC SURGERY, 1994, 57 (06): : 1649 - 1651
  • [27] Extracardiac direct total cavopulmonary connection
    Yamagishi, M
    Nakamura, Y
    Kanazawa, T
    Kawada, N
    ANNALS OF THORACIC SURGERY, 1997, 64 (06): : 1817 - 1819
  • [28] Total cavopulmonary connection via a thoracotomy
    Nanaumi, M
    Asou, T
    Takeda, Y
    Lin, ZB
    Ohara, K
    Yoshimura, H
    ANNALS OF THORACIC SURGERY, 2002, 74 (03): : 917 - 919
  • [29] IN VITRO INVESTIGATION OF THE EFFECT OF FLOW PULSATILITY ON POWER LOSS IN THE TOTAL CAVOPULMONARY CONNECTION
    Tang, Elaine
    Khiabani, Reza H.
    Haggerty, Christopher M.
    Yoganathan, Ajit P.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 1099 - 1100
  • [30] Magnetic resonance imaging and particle image velocimetry used to access hemodynamics in models of the total cavopulmonary connection
    Ensley, Ann E.
    Ramuzat, Agnès
    Healy, Timothy M.
    Chatzimavroudis, George P.
    Sharma, Shiva
    Yoganathan, Ajit P.
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 42 : 159 - 160