THE INFLUENCE OF NOVEL CT RECONSTRUCTION TECHNIQUE AND ECG-GATED TECHNIQUE ON IMAGE QUALITY AND PATIENT DOSE OF CARDIAC COMPUTED TOMOGRAPHY

被引:1
|
作者
Dyakov, I. [1 ]
Stoinova, V. [2 ]
Groudeva, V. [2 ]
Vassileva, J. [1 ]
机构
[1] Natl Ctr Radiobiol & Radiat Protect, Sofia, Bulgaria
[2] Univ Hosp St Ekaterina, Sofia, Bulgaria
关键词
D O I
10.1093/rpd/ncv114
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDIvol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction (AIDR) reconstruction techniques. Further aim was to implement prospective electrocardiogram (ECG) gating for patient dose reduction. The study was performed with Aquilion ONE 320-row CT of Toshiba Medical Systems. Analysis of cardiac CT protocols was performed before and after integration of the new software. The AIDR technique showed more than 50 % reduction in CTDIvol values and 57 % in effective dose. The subjective evaluation of clinical images confirmed the adequate image quality acquired by the AIDR technique. The preliminary results indicated significant dose reduction when using prospective ECG gating by keeping the adequate diagnostic quality of clinical images.
引用
收藏
页码:182 / 184
页数:3
相关论文
共 50 条
  • [41] Comparison of radiation dose, contrast enhancement and image quality of prospective ECG-Gated CT coronary angiography: Single versus dual source CT
    Liang, C. R.
    Ong, C. C.
    Chai, P.
    Teo, L. L. S.
    RADIOGRAPHY, 2021, 27 (03) : 831 - 839
  • [42] Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose
    Feng, Q.
    Yin, Y.
    Hua, X.
    Zhu, R.
    Hua, J.
    Xu, J.
    CLINICAL RADIOLOGY, 2010, 65 (10) : 809 - 814
  • [43] Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system
    Flohr, T
    Ohnesorge, B
    Bruder, H
    Stierstorfer, K
    Simon, J
    Suess, C
    Schaller, S
    MEDICAL PHYSICS, 2003, 30 (10) : 2650 - 2662
  • [44] Image reconstruction of optical computed tomography by using the algebraic reconstruction technique for dose readouts of polymer gel dosimeters
    Shih, Cheng-Ting
    Chang, Yuan-Jen
    Hsu, Jui-Ting
    Chuang, Keh-Shih
    Chang, Shu-Jun
    Wu, Jay
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 942 - 947
  • [45] Novel Approach for Image Reconstruction in Low Dose Computed Tomography
    Pavithra, J.
    Kumar, B. S. Sathish
    2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION, EMBEDDED AND COMMUNICATION SYSTEMS (ICIIECS), 2017,
  • [46] Non-ECG-gated high-pitch CT angiography versus hybrid ECG-gated CT angiography for aorta using 512-slice CT: comparison of image quality and radiation dose
    Lee, Jimin
    Jeong, Yeon Joo
    Lee, Geewon
    Kim, Chang Won
    Kim, Jin You
    Lee, Nam Kyung
    Lee, Han Cheol
    Lee, Ji Won
    ACTA RADIOLOGICA, 2023, 64 (02) : 515 - 523
  • [47] Image reconstruction using an adaptive simultaneous algebraic reconstruction technique in computed tomography
    Qiao Q.
    Huang L.
    He Z.
    Huang, Liyu (huangly@mail.xidian.end.cn), 2016, Science Press (43): : 67 - 72
  • [48] Step-and-shoot prospectively ECG-gated versus retrospectively ECG-gated with tube current modulation coronary CT angiography using the 128-slice MDCT: comparison of image quality and radiation dose
    Jeong, Dong Wook
    Choo, Ki Seok
    Baik, Seung Kug
    Kim, Yong Woo
    Jeon, Ung Bae
    Kim, Jeong Soo
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2011, 52 (02) : 155 - 160
  • [49] Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients
    A. G. d’Agostino
    M. Remy-Jardin
    C. Khalil
    V. Delannoy-Deken
    T. Flohr
    A. Duhamel
    J. Remy
    European Radiology, 2006, 16 : 2137 - 2146
  • [50] Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients
    d'Agostino, A. G.
    Remy-Jardin, M.
    Khalil, C.
    Delannoy-Deken, V.
    Flohr, T.
    Duhamel, A.
    Remy, J.
    EUROPEAN RADIOLOGY, 2006, 16 (10) : 2137 - 2146