A complementary method for automated detection of microaneurysms in fluorescein angiography fundus images to assess diabetic retinopathy

被引:56
|
作者
Tavakoli, Meysam [1 ,2 ,3 ]
Shahri, Reza Pourreza [3 ,4 ]
Pourreza, Hamidreza [3 ,5 ]
Mehdizadeh, Alireza [6 ,7 ]
Banaee, Touka [3 ,8 ]
Toosi, Mohammad Hosein Bahreini [9 ]
机构
[1] Oklahoma State Univ, Dept Phys, Stillwater, OK 74078 USA
[2] Mashhad Univ Med Sci, Ctr Res Med Phys & Biomed Imaging, Mashhad, Iran
[3] MUMS & Ferdowsi Univ Mashhad, Eye Image Anal Res Grp, Mashhad, Iran
[4] Univ Texas Dallas, Dept Elect Engn, Dallas, TX 75230 USA
[5] Ferdowsi Univ Mashhad, Dept Comp Engn, Mashhad, Iran
[6] Shiraz Univ Med Sci, Ctr Res Med Phys, Shiraz, Iran
[7] Shiraz Univ Med Sci, Biomed Engn Image Proc Lab, Shiraz, Iran
[8] Mashhad Univ Med Sci, Khatam Al Anbia Hosp, Ophthalm Res Ctr, Mashhad, Iran
[9] Mashhad Univ Med Sci, Dept Med Phys, Sch Med, Mashhad, Iran
关键词
Computer aided diagnosis; Diabetic retinopathy; Fluorescein angiography; Fundus images; Radon transform; Microaneurysms; QUANTIFICATION; PHOTOGRAPHS; PREVALENCE; TRANSFORM;
D O I
10.1016/j.patcog.2013.03.011
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Early detection of microaneurysms (MAs), the first sign of Diabetic Retinopathy (DR), is an essential first step in automated detection of DR to prevent vision loss and blindness. This study presents a novel and different algorithm for automatic detection of MAs in fluorescein angiography (FA) fundus images, based on Radon transform (RT) and multi-overlapping windows. This project addresses a novel method, in detection of retinal land marks and lesions to diagnose the DR. At the first step, optic nerve head (ONH) was detected and masked. In preprocessing stage, top-hat transformation and averaging filter were applied to remove the background. In main processing section, firstly, we divided the whole preprocessed image into sub-images and then segmented and masked the vascular tree by applying RT in each sub-image. After detecting and masking retinal vessels and ONH, MAs were detected and numbered by using RT and appropriated thresholding. The results of the proposed method were evaluated on three different retinal images databases, the Mashhad Database with 120 FA fundus images, Second Local Database from Tehran with 50 FA retinal images and a part of Retinopathy Online Challenge (ROC) database with 22 images. Automated DR detection demonstrated a sensitivity and specificity of 94% and 75% for Mashhad database and 100% and 70% for the Second Local Database respectively. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2740 / 2753
页数:14
相关论文
共 50 条
  • [21] Automated detection of diabetic retinopathy in fundus images using fused features
    Iqra Bibi
    Junaid Mir
    Gulistan Raja
    Physical and Engineering Sciences in Medicine, 2020, 43 : 1253 - 1264
  • [22] Enhancement of Retinal Images for Microaneurysms Detection in Diabetic Retinopathy
    Mazlan, Noratikah
    Yazid, Haniza
    Sabri, Nur Rafidah
    2018 IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED), 2018,
  • [23] Automated Microaneurysms Detection in Fundus Images Using Image Segmentation
    Sreng, Syna
    Maneerat, Noppadol
    Hamamoto, Kazuhiko
    2017 INTERNATIONAL CONFERENCE ON DIGITAL ARTS, MEDIA AND TECHNOLOGY (ICDAMT): DIGITAL ECONOMY FOR SUSTAINABLE GROWTH, 2017, : 19 - 23
  • [24] Fundus fluorescein angiography in retinopathy of prematurity
    Hans, Amandeep
    Narang, Subina
    Sindhu, Meenakshi
    Jain, Suksham
    Chawla, Deepak
    EYE, 2022, 36 (08) : 1604 - 1609
  • [25] Differential distribution of manifest lesions in diabetic retinopathy by fundus fluorescein angiography and fundus photography
    Li, Xiaoli
    Xie, Jie
    Zhang, Liang
    Cui, Ying
    Zhang, Guanrong
    Wang, Jun
    Zhang, Aiping
    Chen, Xiangting
    Huang, Tian
    Meng, Qianli
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [26] Allergy Test Dosage of Fluorescein Detects Diabetic Retinopathy Changes in Fundus Fluorescein Angiography
    Yang, Jian-Feng
    Wang, Yun
    Zhou, Lingling
    Tan, Shaoying
    Hu, Zhanchi
    Ng, Tsz Kin
    Cen, Ling-Ping
    DIAGNOSTICS, 2023, 13 (23)
  • [28] Fundus fluorescein angiography in retinopathy of prematurity
    Amandeep Hans
    Subina Narang
    Meenakshi Sindhu
    Suksham Jain
    Deepak Chawla
    Eye, 2022, 36 : 1604 - 1609
  • [29] Comparison of fundus fluorescein angiography and fundus photography grading criteria for early diabetic retinopathy
    Xin-Yue Li
    Shu Wang
    Li Dong
    Hong Zhang
    International Journal of Ophthalmology, 2022, (02) : 261 - 267
  • [30] Comparison of fundus fluorescein angiography and fundus photography grading criteria for early diabetic retinopathy
    Li, Xin-Yue
    Wang, Shu
    Dong, Li
    Zhang, Hong
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (02) : 261 - 267