A complementary method for automated detection of microaneurysms in fluorescein angiography fundus images to assess diabetic retinopathy

被引:56
|
作者
Tavakoli, Meysam [1 ,2 ,3 ]
Shahri, Reza Pourreza [3 ,4 ]
Pourreza, Hamidreza [3 ,5 ]
Mehdizadeh, Alireza [6 ,7 ]
Banaee, Touka [3 ,8 ]
Toosi, Mohammad Hosein Bahreini [9 ]
机构
[1] Oklahoma State Univ, Dept Phys, Stillwater, OK 74078 USA
[2] Mashhad Univ Med Sci, Ctr Res Med Phys & Biomed Imaging, Mashhad, Iran
[3] MUMS & Ferdowsi Univ Mashhad, Eye Image Anal Res Grp, Mashhad, Iran
[4] Univ Texas Dallas, Dept Elect Engn, Dallas, TX 75230 USA
[5] Ferdowsi Univ Mashhad, Dept Comp Engn, Mashhad, Iran
[6] Shiraz Univ Med Sci, Ctr Res Med Phys, Shiraz, Iran
[7] Shiraz Univ Med Sci, Biomed Engn Image Proc Lab, Shiraz, Iran
[8] Mashhad Univ Med Sci, Khatam Al Anbia Hosp, Ophthalm Res Ctr, Mashhad, Iran
[9] Mashhad Univ Med Sci, Dept Med Phys, Sch Med, Mashhad, Iran
关键词
Computer aided diagnosis; Diabetic retinopathy; Fluorescein angiography; Fundus images; Radon transform; Microaneurysms; QUANTIFICATION; PHOTOGRAPHS; PREVALENCE; TRANSFORM;
D O I
10.1016/j.patcog.2013.03.011
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Early detection of microaneurysms (MAs), the first sign of Diabetic Retinopathy (DR), is an essential first step in automated detection of DR to prevent vision loss and blindness. This study presents a novel and different algorithm for automatic detection of MAs in fluorescein angiography (FA) fundus images, based on Radon transform (RT) and multi-overlapping windows. This project addresses a novel method, in detection of retinal land marks and lesions to diagnose the DR. At the first step, optic nerve head (ONH) was detected and masked. In preprocessing stage, top-hat transformation and averaging filter were applied to remove the background. In main processing section, firstly, we divided the whole preprocessed image into sub-images and then segmented and masked the vascular tree by applying RT in each sub-image. After detecting and masking retinal vessels and ONH, MAs were detected and numbered by using RT and appropriated thresholding. The results of the proposed method were evaluated on three different retinal images databases, the Mashhad Database with 120 FA fundus images, Second Local Database from Tehran with 50 FA retinal images and a part of Retinopathy Online Challenge (ROC) database with 22 images. Automated DR detection demonstrated a sensitivity and specificity of 94% and 75% for Mashhad database and 100% and 70% for the Second Local Database respectively. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2740 / 2753
页数:14
相关论文
共 50 条
  • [1] FLUORESCEIN ANGIOGRAPHY OF FUNDUS IN DIABETIC RETINOPATHY
    KOHNER, EM
    DOLLERY, CT
    BRITISH MEDICAL BULLETIN, 1970, 26 (02) : 166 - +
  • [2] Automatic detection of microaneurysms in colour fundus images for diabetic retinopathy screening
    Rahim, Sarni Suhaila
    Jayne, Chrisina
    Palade, Vasile
    Shuttleworth, James
    NEURAL COMPUTING & APPLICATIONS, 2016, 27 (05): : 1149 - 1164
  • [3] Automatic detection of microaneurysms in colour fundus images for diabetic retinopathy screening
    Sarni Suhaila Rahim
    Chrisina Jayne
    Vasile Palade
    James Shuttleworth
    Neural Computing and Applications, 2016, 27 : 1149 - 1164
  • [4] AUTOMATIC DETECTION OF MICROANEURYSMS IN DIABETIC FLUORESCEIN ANGIOGRAPHY
    BAUDOIN, CE
    LAY, BJ
    KLEIN, JC
    REVUE D EPIDEMIOLOGIE ET DE SANTE PUBLIQUE, 1984, 32 (3-4): : 254 - 261
  • [5] Automated detection of diabetic retinopathy on digital fundus images
    Sinthanayothin, C
    Boyce, JF
    Williamson, TH
    Cook, HL
    Mensah, E
    Lal, S
    Usher, D
    DIABETIC MEDICINE, 2002, 19 (02) : 105 - 112
  • [6] Automated Detection of Microaneurysms to assess Diabetics Retinopathy
    Jini, M. V. Anifa
    Jayasingh, Roopa
    2014 INTERNATIONAL CONFERENCE ON ELECTRONICS AND COMMUNICATION SYSTEMS (ICECS), 2014,
  • [7] AUTOMATED DETECTION OF LEAKAGE SITES IN FUNDUS FLUORESCEIN ANGIOGRAPHY FOR DIABETIC MACULOPATHY
    Kwong, M. T.
    Zheng, Y.
    Parry, D.
    Sahni, J. N.
    Raj, A.
    Harding, S. P.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) : 460 - 460
  • [8] Automated Optic Nerve Head Detection in Fluorescein Angiography Fundus Images
    Tavakoli, M.
    Toosi, M. H. Bahreini
    Pourreza, R.
    Banaee, T.
    Pourreza, H. R.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3057 - 3060
  • [9] A method to assist in the diagnosis of early diabetic retinopathy: Image processing applied to detection of microaneurysms in fundus images
    Rosas-Romero, Roberto
    Martinez-Carballido, Jorge
    Hernandez-Capistran, Jonathan
    Uribe-Valencia, Laura J.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 44 : 41 - 53
  • [10] Automated vessel density detection in fluorescein angiography images correlates with vision in proliferative diabetic retinopathy
    Ramchandran, Rajeev
    Bawany, Mohammad H.
    Ding, Li
    Sharma, Gaurav
    Wykoff, Charles Clifton
    Kuriyan, Ajay E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)