MR Navigated Breast Surgery: Method and Initial Clinical Experience

被引:0
|
作者
Carter, Timothy [1 ]
Tanner, Christine [1 ]
Beechey-Newman, Nicolas [2 ]
Barratt, Dean [1 ]
Hawkes, David [1 ]
机构
[1] UCL, Ctr Med Image Comp, Mortimer St, London WC1E 6BT, England
[2] Guys Hosp, Hedley Atkins Breast Unit, London SE1 9RT, England
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
3D dynamic contrast enhanced magnetic resonance (MR) images may help to reduce the high re-excision rate associated with breast conserving surgery. However these images are acquired prone, whilst surgery is performed Supine which results in a large deformation that limits their usefulness. We describe here a registration technique based on a biomechanical model to account for soft tissue deformation between prone MR imaging and surgery. The accuracies of the individual registration steps are assessed off-line. We then report our first clinical experience with an image-guided surgery system which incorporates these algorithms. The system's accuracy is assessed against tracked ultrasound images, and is determined to be around 5mm for this case.
引用
收藏
页码:356 / 363
页数:8
相关论文
共 50 条
  • [31] Time-resolved MR angiography of the upper abdomen: initial clinical experience
    L. Van Hoe
    T. De Jaegere
    H. Bosmans
    J. Bogaert
    R. Oyen
    G. Marchal
    European Radiology, 1999, 9 : 418 - 421
  • [32] Initial clinical experience with the MR-Linac system-Patient perspective
    Day, Jonathan
    Moreira, A.
    Day, J.
    Konig-Nettelmann, B.
    Andratschke, N.
    Guckenberger, M.
    Schuler, H. I. Garcia
    Witt, C.
    Tanadini-Lang, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1124 - 1124
  • [33] MR IMAGING-GUIDED LOCALIZATION AND BIOPSY OF BREAST-LESIONS - INITIAL EXPERIENCE
    OREL, SG
    SCHNALL, MD
    NEWMAN, RW
    POWELL, CM
    TOROSIAN, MH
    ROSATO, EF
    RADIOLOGY, 1994, 193 (01) : 97 - 102
  • [34] MR-IMAGING OF THE BREAST - TECHNICAL APPROACH AND CLINICAL-EXPERIENCE
    HARMS, SE
    FLAMIG, DP
    RADIOGRAPHICS, 1993, 13 (04) : 905 - 912
  • [35] Robotic pancreatic surgery is no substitute for experience and clinical judgment: an initial experience and literature review
    Michael Wayne
    Justin Steele
    Mazen Iskandar
    Avram Cooperman
    World Journal of Surgical Oncology, 11
  • [36] Robotic pancreatic surgery is no substitute for experience and clinical judgment: an initial experience and literature review
    Wayne, Michael
    Steele, Justin
    Iskandar, Mazen
    Cooperman, Avram
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2013, 11 : 1 - 3
  • [37] Concept and clinical evaluation of navigated control in spine surgery
    ASME Dynamic Systems and Control Division (DSC); IEEE Industrial Electronics Society (IES); IEEE Robotics and Automation Society (RAS) (Institute of Electrical and Electronics Engineers Inc., United States):
  • [38] A clinical, noninvasive, MR imaging monitored ultrasound surgery method
    Hynynen, K
    Freund, WR
    Cline, HE
    Chung, AH
    Watkins, RD
    Vetro, JP
    Jolesz, FA
    RADIOGRAPHICS, 1996, 16 (01) : 185 - 195
  • [39] Concept and clinical evaluation of navigated control in spine surgery
    Kneissler, M
    Hein, A
    Mätzig, M
    Thomale, UW
    Lueth, TC
    Woiciechowsky, C
    PROCEEDINGS OF THE 2003 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM 2003), VOLS 1 AND 2, 2003, : 1084 - 1089
  • [40] Initial clinical experience with a novel flexible endoscopic robot for transanal surgery
    Morino, M.
    Forcignano, E.
    Arezzo, A.
    TECHNIQUES IN COLOPROCTOLOGY, 2022, 26 (04) : 301 - 308