The influence of the root cross-section on the stress distribution in teeth restored with a positive-locking post and core design: a finite element study

被引:2
|
作者
Schilling, Kai-Uwe
Rottner, Kurt [2 ]
Boldt, Julian [3 ]
Proff, Peter [1 ]
Gredes, Tomasz [4 ]
Richter, Ernst-Juergen
Reicheneder, Claudia [1 ]
机构
[1] Univ Regensburg, Dept Orthodont, D-93053 Regensburg, Germany
[2] Prokuro Med Tech GmbH, Moosach, Germany
[3] Univ Wurzburg, Dept Prosthodont, Wurzburg, Germany
[4] Ernst Moritz Arndt Univ Greifswald, Dept Orthodont Prevent & Paediat Dent, Greifswald, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2008年 / 53卷 / 05期
关键词
finite element method; positive locking; post and core restoration; radicular dentin; tooth;
D O I
10.1515/BMT.2008.037
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Human teeth with substantial coronal defects are subject to reconstruction by means of post and core restorations. Typically, such a restoration comprises a slightly cylindrical post onto which an abutment of varying shape, depending on the designated restoration, is attached. As clinical results are not satisfactory to date, we proposed a new proprietary post and core design which makes use of positive locking. As this prefabricated system is not customised to an individual root's cross-sectional geometry (usually oval), a varying amount of radicular dentin is left in periphery of the core's outer edge. The aim of this study was to assess the implications of this fact, i.e., whether the root has to endure higher overall stress levels which ultimately may lead to failure of one of the components involved. A series of finite element simulations were performed to evaluate stress and strain on the system, in which the proposed post and core was embedded into a virtual dentin cylinder of different diameters, ranging from flush mounting of the restoration to a dentin excess of 4 mm, and subsequently loaded with forces with two angles of attack (90 degrees and 130 degrees). The results show that flush mounting yields an agreeable stress and strain distribution within the radicular dentin, but overall stress levels drop significantly with an excess of 0.5 mm of surrounding dentin. More than 1 mm excess was not found to have profound positive effects.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 27 条
  • [21] Influence of Preparation Depth and Design on Stress Distribution in Maxillary Central Incisors Restored with Ceramic Veneers: A 3D Finite Element Analysis
    Tsouknidas, Alexandros
    Karaoglani, Eleni
    Michailidis, Nikolaos
    Kugiumtzis, Dimitris
    Pissiotis, Argiris
    Michalakis, Konstantinos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (02): : 151 - 160
  • [22] Influence of tooth preparation design on the stress distribution in maxillary central incisors restored by means of alumina porcelain veneers: A 3D-finite element analysis
    Zarone, F
    Apicella, D
    Sorrentino, R
    Ferro, V
    Aversa, R
    Apicella, A
    DENTAL MATERIALS, 2005, 21 (12) : 1178 - 1188
  • [23] Fracture Resistance and Stress Distribution Pattern of Different Posts-Core Systems in Immature Teeth: An In Vitro Study and 3D Finite Element Analysis
    Khadar, Shahnaz
    Sapkale, Kishor
    Patil, Pravinkumar G.
    Abrar, Sayed
    Ramugade, Manoj
    Huda, Febel
    INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022
  • [24] A three-dimensional finite element analysis of the effects of restorative materials and post geometry on stress distribution in mandibular molar tooth restored with post-core crown (Retraction of vol 31, pg 171, 2012)
    Mahmoudi, Mojtaba
    Saidi, Alireza
    Gandjalikhan Nassab, Saied Abdolreza
    Hashemipour, Maryam Alsadat
    DENTAL MATERIALS JOURNAL, 2014, 33 (01) : 147 - 147
  • [25] Influence of connector design and material composition and veneering on the stress distribution of all-ceramic fixed dental prostheses: A finite element study
    Moellers, Kristina
    Paetzold, Wiebke
    Parkot, Daniel
    Kirsten, Armin
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Fischer, Horst
    DENTAL MATERIALS, 2011, 27 (08) : E171 - E175
  • [26] Effect of Ferrule Design on Stress Distribution of Maxillary Incisor Rehabilitated with Ceramic Crown and PEEK Post-Core Material: A 3D Finite Element Analysis
    Alberto, Laura H. J.
    Zhang, Zhaoxu
    Duan, Yuanyuan
    Palma, Paulo J.
    Camilleri, Josette
    Marques, Joana A.
    Ferreira, Jose M. F.
    CERAMICS-SWITZERLAND, 2023, 6 (04): : 2256 - 2268
  • [27] RETRACTED: A three-dimensional finite element analysis of the effects of restorative materials and post geometry on stress distribution in mandibular molar tooth restored with post-core crown (Retracted article. See vol. 33, pg. 147, 2014)
    Mahmoudi, Mojtaba
    Saidi, Alireza
    Nassab, Saied Abdolreza Gandjalikhan
    Hashemipour, Maryam Alsadat
    DENTAL MATERIALS JOURNAL, 2012, 31 (02) : 171 - 179